Real-Time Analysis of Oxygen Gradient in Oocyte Respiration Using a High-Density Microelectrode Array

被引:5
|
作者
Tedjo, William [1 ]
Obeidat, Yusra [2 ]
Catandi, Giovana [3 ]
Carnevale, Elaine [3 ]
Chen, Thomas [1 ,4 ]
机构
[1] Colorado State Univ, Dept Elect & Comp Engn, Ft Collins, CO 80523 USA
[2] Yarmouk Univ, Elect Engn Dept, Irbid 21163, Jordan
[3] Colorado State Univ, Dept Biomed Sci, Ft Collins, CO 80523 USA
[4] Colorado State Univ, Sch Biomed Engn, Ft Collins, CO 80523 USA
来源
BIOSENSORS-BASEL | 2021年 / 11卷 / 08期
基金
美国国家科学基金会;
关键词
CMOS biosensor; microelectrode array; electrochemistry; microfluidics; oxygen concentration gradient; oxygen flux; oxygen consumption rate; BOVINE EMBRYOS; ASCORBIC-ACID; CONSUMPTION; CHIP; CELL; FABRICATION; DOPAMINE; HYPOXIA; CULTURE; SENSOR;
D O I
10.3390/bios11080256
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Physiological events related to oxygen concentration gradients provide valuable information to determine the state of metabolizing biological cells. The existing oxygen sensing methods (i.e., optical photoluminescence, magnetic resonance, and scanning electrochemical) are well-established and optimized for existing in vitro analyses. However, such methods also present various limitations in resolution, real-time sensing performance, complexity, and costs. An electrochemical imaging system with an integrated microelectrode array (MEA) would offer attractive means of measuring oxygen consumption rate (OCR) based on the cell's two-dimensional (2D) oxygen concentration gradient. This paper presents an application of an electrochemical sensor platform with a custom-designed complementary-metal-oxide-semiconductor (CMOS)-based microchip and its Pt-coated surface MEA. The high-density MEA provides 16,064 individual electrochemical pixels that cover a 3.6 mm x 3.6 mm area Utilizing the three-electrode configuration, the system is capable of imaging low oxygen concentration (18.3 mu M, 0.58 mg/L, or 13.8 mmHg) at 27.5 mu m spatial resolution and up to 4 Hz temporal resolution. In vitro oxygen imaging experiments were performed to analyze bovine cumulus-oocytes-complexes cells OCR and oxygen flux density. The integration of a microfluidic system allows proper bio-sample handling and delivery to the MEA surface for imaging. Finally, the imaging results are processed and presented as 2D heatmaps, representing the dissolved oxygen concentration in the immediate proximity of the MEA. This paper provides the results of real-time 2D imaging of OCR of live cells/tissues to gain spatial and temporal dynamics of target cell metabolism.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Single-cell individualized electroporation with real-time impedance monitoring using a microelectrode array chip
    Zhizhong Zhang
    Tianyang Zheng
    Rong Zhu
    Microsystems & Nanoengineering, 6
  • [42] Real-time cell electrophysiology using a multi-channel dielectrophoretic-dot microelectrode array
    Fatoyinbo, Henry O.
    Kadri, Nahrizul A.
    Gould, David H.
    Hoettges, Kai F.
    Labeed, Fatima H.
    ELECTROPHORESIS, 2011, 32 (18) : 2541 - 2549
  • [43] Single-cell individualized electroporation with real-time impedance monitoring using a microelectrode array chip
    Zhang, Zhizhong
    Zheng, Tianyang
    Zhu, Rong
    MICROSYSTEMS & NANOENGINEERING, 2020, 6 (01)
  • [44] The Conformal, High-Density SpineWrap Microelectrode Array for Focal Stimulation and Selective Muscle Recruitment
    Russman, Samantha M.
    Montgomery-Walsh, Rhea
    Vatsyayan, Ritwik
    Sang, U. Hoi
    Diaz-Aguilar, Luis D.
    Chang, Eric Y.
    Tang, Qingbo
    Lee, Keundong
    Yaksh, Tony L.
    Ben-Haim, Sharona
    Ciacci, Joseph
    Dayeh, Shadi A.
    ADVANCED FUNCTIONAL MATERIALS, 2025,
  • [45] High-density CMOS Microelectrode Array System for Impedance Spectroscopy and Imaging of Biological Cells
    Vijay, Viswam
    Raziyeh, Bounik
    Amir, Shadmani
    Jelena, Dragas
    Alicia, Boos Julia
    Axel, Birchler
    Jan, Muller
    Chen Yihui
    Andreas, Hierlemann
    2016 IEEE SENSORS, 2016,
  • [46] Independent-component-analysis-based spike sorting algorithm for high-density microelectrode array data processing
    Bio Engineering Laboratory, Department BSSE, ETH Zurich, CH-4058 Basel, Switzerland
    不详
    Proc. IEEE Sens., 1930, (384-386):
  • [47] Independent-Component-Analysis-Based Spike Sorting Algorithm for High-Density Microelectrode Array Data Processing
    Jan, Sedivy
    Urs, Frey
    David, Jaeckel
    Andreas, Hierlemann
    2009 IEEE SENSORS, VOLS 1-3, 2009, : 384 - 386
  • [48] Functional imaging of brain organoids using high-density microelectrode arrays
    Manuel Schröter
    Congwei Wang
    Marco Terrigno
    Philipp Hornauer
    Ziqiang Huang
    Ravi Jagasia
    Andreas Hierlemann
    MRS Bulletin, 2022, 47 : 530 - 544
  • [49] Functional imaging of brain organoids using high-density microelectrode arrays
    Schroter, Manuel
    Wang, Congwei
    Terrigno, Marco
    Hornauer, Philipp
    Huang, Ziqiang
    Jagasia, Ravi
    Hierlemann, Andreas
    MRS BULLETIN, 2022, 47 (06) : 530 - 544
  • [50] Intuitive real-time control strategy for high-density myoelectric hand prosthesis using deep and transfer learning
    Simon Tam
    Mounir Boukadoum
    Alexandre Campeau-Lecours
    Benoit Gosselin
    Scientific Reports, 11