Real-Time Analysis of Oxygen Gradient in Oocyte Respiration Using a High-Density Microelectrode Array

被引:5
|
作者
Tedjo, William [1 ]
Obeidat, Yusra [2 ]
Catandi, Giovana [3 ]
Carnevale, Elaine [3 ]
Chen, Thomas [1 ,4 ]
机构
[1] Colorado State Univ, Dept Elect & Comp Engn, Ft Collins, CO 80523 USA
[2] Yarmouk Univ, Elect Engn Dept, Irbid 21163, Jordan
[3] Colorado State Univ, Dept Biomed Sci, Ft Collins, CO 80523 USA
[4] Colorado State Univ, Sch Biomed Engn, Ft Collins, CO 80523 USA
来源
BIOSENSORS-BASEL | 2021年 / 11卷 / 08期
基金
美国国家科学基金会;
关键词
CMOS biosensor; microelectrode array; electrochemistry; microfluidics; oxygen concentration gradient; oxygen flux; oxygen consumption rate; BOVINE EMBRYOS; ASCORBIC-ACID; CONSUMPTION; CHIP; CELL; FABRICATION; DOPAMINE; HYPOXIA; CULTURE; SENSOR;
D O I
10.3390/bios11080256
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Physiological events related to oxygen concentration gradients provide valuable information to determine the state of metabolizing biological cells. The existing oxygen sensing methods (i.e., optical photoluminescence, magnetic resonance, and scanning electrochemical) are well-established and optimized for existing in vitro analyses. However, such methods also present various limitations in resolution, real-time sensing performance, complexity, and costs. An electrochemical imaging system with an integrated microelectrode array (MEA) would offer attractive means of measuring oxygen consumption rate (OCR) based on the cell's two-dimensional (2D) oxygen concentration gradient. This paper presents an application of an electrochemical sensor platform with a custom-designed complementary-metal-oxide-semiconductor (CMOS)-based microchip and its Pt-coated surface MEA. The high-density MEA provides 16,064 individual electrochemical pixels that cover a 3.6 mm x 3.6 mm area Utilizing the three-electrode configuration, the system is capable of imaging low oxygen concentration (18.3 mu M, 0.58 mg/L, or 13.8 mmHg) at 27.5 mu m spatial resolution and up to 4 Hz temporal resolution. In vitro oxygen imaging experiments were performed to analyze bovine cumulus-oocytes-complexes cells OCR and oxygen flux density. The integration of a microfluidic system allows proper bio-sample handling and delivery to the MEA surface for imaging. Finally, the imaging results are processed and presented as 2D heatmaps, representing the dissolved oxygen concentration in the immediate proximity of the MEA. This paper provides the results of real-time 2D imaging of OCR of live cells/tissues to gain spatial and temporal dynamics of target cell metabolism.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Real-time signal processing for high-density microelectrode array systems
    Imfeld, K.
    Maccione, A.
    Gandolfo, M.
    Martinoia, S.
    Farine, P-A.
    Koudelka-Hep, M.
    Berdondini, L.
    INTERNATIONAL JOURNAL OF ADAPTIVE CONTROL AND SIGNAL PROCESSING, 2009, 23 (11) : 983 - 998
  • [2] An Integrated Biosensor System With a High-Density Microelectrode Array for Real-Time Electrochemical Imaging
    Tedjo, William
    Chen, Thomas
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2020, 14 (01) : 20 - 35
  • [3] Spatiotemporal norepinephrine mapping using a high-density CMOS microelectrode array
    Wydallis, John B.
    Feeny, Rachel M.
    Wilson, William
    Kern, Tucker
    Chen, Tom
    Tobet, Stuart
    Reynolds, Melissa M.
    Henry, Charles S.
    LAB ON A CHIP, 2015, 15 (20) : 4075 - 4082
  • [4] Applicability of independent component analysis on high-density microelectrode array recordings
    Jaeckel, David
    Frey, Urs
    Fiscella, Michele
    Franke, Felix
    Hierlemann, Andreas
    JOURNAL OF NEUROPHYSIOLOGY, 2012, 108 (01) : 334 - 348
  • [5] Recording from defined populations of retinal ganglion cells using a high-density CMOS-integrated microelectrode array with real-time switchable electrode selection
    Fiscella, Michele
    Farrow, Karl
    Jones, Ian L.
    Jaeckel, David
    Mueller, Jan
    Frey, Urs
    Bakkum, Douglas J.
    Hantz, Peter
    Roska, Botond
    Hierlemann, Andreas
    JOURNAL OF NEUROSCIENCE METHODS, 2012, 211 (01) : 103 - 113
  • [6] Cell recordings with a CMOS high-density microelectrode array
    Frey, U.
    Sanchez-Bustamante, C. D.
    Ugniwenko, T.
    Heer, F.
    Sedivy, J.
    Hafizovic, S.
    Roscic, B.
    Fussenegger, M.
    Blau, A.
    Egert, U.
    Hierlemann, A.
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 167 - +
  • [7] Design and Fabrication of A High-Density Flexible Microelectrode Array
    Li, Tengyue
    Sun, Bin
    Xia, Kai
    Zeng, Qi
    Wu, Tianzhun
    Humayun, Mark S.
    2017 IEEE 12TH INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS (NEMS), 2017, : 299 - 302
  • [8] High-density microelectrode array recordings and real-time spike sorting for closed-loop experiments: an emerging technology to study neural plasticity
    Franke, Felix
    Jaeckel, David
    Dragas, Jelena
    Mueller, Jan
    Radivojevic, Milos
    Bakkum, Douglas
    Hierlemann, Andreas
    FRONTIERS IN NEURAL CIRCUITS, 2012, 6
  • [9] Automated Navigation of a Glass Micropipette on a High-Density Microelectrode Array
    Lin, Jing
    Obien, Marie Engelene J.
    Hierlemann, Andreas
    Frey, Urs
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 881 - 884
  • [10] Real-time prediction of high-density EAST disruptions using random forest
    Hu, W. H.
    Rea, C.
    Yuan, Q. P.
    Erickson, K. G.
    Chen, D. L.
    Shen, B.
    Huang, Y.
    Xiao, J. Y.
    Chen, J. J.
    Duan, Y. M.
    Zhang, Y.
    Zhuang, H. D.
    Xu, J. C.
    Montes, K. J.
    Granetz, R. S.
    Zeng, L.
    Qian, J. P.
    Xiao, B. J.
    Li, J. G.
    NUCLEAR FUSION, 2021, 61 (06)