Detection of nucleated red blood cells using the Mindray BC-6800Plus hematology analyzer: a clinical performance evaluation

被引:5
|
作者
Wang, Nengyong [1 ]
Jiang, Junyao [1 ]
Wang, Ji'an [1 ]
He, Yao [1 ]
Wen, Ning [1 ]
Liu, Yulin [1 ]
Wang, Yashu [1 ]
Li, Haijun [1 ]
Shi, Ping [1 ]
机构
[1] Guangyuan Cent Hosp, Lab Dept, Guangyuan 628017, Peoples R China
关键词
Hematology analyzer; nucleated red blood; parameter; manual microscopic examination;
D O I
10.21037/apm-21-1772
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: With the development of instrument technology, the functions and detection methods of automatic blood cell analyzers have become more complex. To ensure optimal clinical applicability, it is crucial to select an automatic blood cell analyzer with excellent clinical detection performance. This study evaluated the latest Mindray BC-6800Plus automatic blood cell analyzer and assessed its performance in the detection of nucleated red blood cells (NRBCs). Methods: A total of 490 clinical blood samples were used to assess the performance of the instrument, including parameters such as precision, linearity, conformity rate of manual microscopic examination, carryover, and limit of quantitation. Results: The instrument showed a small carryover (<= 0.02) and excellent linearity (R-2 >= 0.9986). The reproducibility of the sample tests was satisfactory, and the coefficient of variation (CV) of the test results [0.98-1.72% and 0.62-6.97% for white blood cells (WBCs) and NRBCs, respectively] were significantly lower than that declared by the manufacturer (2.5% and 20% for WBCs and NRBCs, respectively). Thus, the BC-6800Plus satisfies the requirements of clinical testing. Two separate Mindray BC-6800Plus machines were tested and found to be in good agreement with each other and with manual microscopy methods. Furthermore, WBC and NRBC counts were highly consistent with results obtained using the XN-9100 blood analyzer. Conclusions: The Mindray BC-6800Plus is an excellent analyzer that can provide timely and accurate reports for clinical laboratory detection of NRBC.
引用
收藏
页码:8808 / 8817
页数:10
相关论文
共 50 条
  • [1] Automated nucleated red blood cell count using the Mindray BC-6800 hematology analyzer
    Houyhongthong, V.
    Nunphuak, W.
    Sripatumtong, C.
    Parnsamut, C.
    Ketloy, C.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2018, 40 (05) : 611 - 616
  • [2] Establishing reference intervals for extended red blood cell parameters with the Mindray BC-6800Plus hematology analyzer in a Chinese population
    Luo, Yanping
    Wang, Shuaiyan
    Chen, Zhuocheng
    Lin, Shan
    Guo, Sanping
    Mo, Hongmei
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2024,
  • [3] ESTABLISHING REFERENCE INTERVALS FOR EXTENDED RED BLOOD CELL PARAMETERS WITH THE MINDRAY BC-6800PLUS HEMATOLOGY ANALYZER IN A CHINESE POPULATION
    Luo, Yanping
    Wang, Shuaiyan
    Chen, Zhuocheng
    Lin, Shan
    Guo, Sanping
    Mo, Hongmei
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2024, 46 : 60 - 61
  • [4] Reference intervals for clinically reportable platelet parameters on the Mindray BC-6800Plus hematology analyzer
    Kim, Hanah
    Hur, Mina
    Kim, Seung-Wan
    Moon, Hee-Won
    Yun, Yeo-Min
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2020, 58 (10) : E213 - E215
  • [5] Hemoglobin Shelby interfered with the leukocyte differential channel of the Mindray BC-6800Plus hematology analyzer: a case report
    Urrechaga, Eloisa
    Merino, Monica
    Fernandez, Monica
    Aguirrezabal, Jaione
    del Orbe, Rafael
    JOURNAL OF LABORATORY AND PRECISION MEDICINE, 2022, 7
  • [6] Hemoglobin Shelby interfered with the leukocyte differential channel of the Mindray BC-6800Plus hematology analyzer: a case report
    Urrechaga, Eloisa
    Merino, Monica
    Fernandez, Monica
    Aguirrezabal, Jaione
    del Orbe, Rafael
    JOURNAL OF LABORATORY AND PRECISION MEDICINE, 2022, 7
  • [7] Evaluation of IPF counting on Mindray BC-6800 hematology analyzer
    Pecoraro, A.
    Troia, A.
    Sacco, M.
    Maggio, A.
    Di Marzo, R.
    Gioia, M.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2016, 38 (05) : E89 - E92
  • [8] COMPARISON BETWEEN SYSMEX XN-1000 AND MINDRAY BC-6800PLUS HEMATOLOGY ANALYZERS
    Molero-Vilches, Ignacio
    Bermejo-Rodriguez, Alfredo
    Nieto-Borrajo, Maria Elva
    Morales-Garcia, Luis Javier
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2023, 45 : 121 - 121
  • [9] Performance evaluation of low platelet count and platelet clumps detection on Mindray BC-6800 hematology analyzer
    Fuster, Oscar
    Andino, Belinda
    Laiz, Begona
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2016, 54 (02) : E49 - E51
  • [10] Serous body fluid evaluation using the new automated haematology analyser Mindray BC-6800Plus
    Boldu, Laura
    Laguna, Javier
    Casanova, Alexandra
    Garcia, Saray
    Molina, Angel
    Merino, Anna
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2022, 60 (11) : 1786 - 1795