Kinetic model-based factor analysis of dynamic sequences for 82-rubidium cardiac positron emission tomography

被引:10
|
作者
Klein, R. [1 ]
Beanlands, R. S. [1 ]
Wassenaar, R. W. [2 ]
Thorn, S. L. [1 ]
Lamoureux, M. [1 ]
DaSilva, J. N. [1 ]
Adler, A. [3 ]
deKemp, R. A. [1 ]
机构
[1] Univ Ottawa, Inst Heart, Natl Cardiac PET Ctr, Ottawa, ON K1Y 4W7, Canada
[2] Ottawa Hosp, Div Nucl Med, Ottawa, ON K1Y 4E9, Canada
[3] Carleton Univ, Ottawa, ON K1S 5B6, Canada
关键词
factor analysis; cardiac; myocardial perfusion; PET; image analysis; MYOCARDIAL BLOOD-FLOW; PROGNOSTIC VALUE; RB-82; PET; IMAGES; INPUT; DERIVATION; TIME;
D O I
10.1118/1.3438474
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Factor analysis has been pursued as a means to decompose dynamic cardiac PET images into different tissue types based on their unique temporal signatures to improve quantification of physiological function. In this work, the authors present a novel kinetic model-based (MB) method that includes physiological models of factor relationships within the decomposition process. The physiological accuracy of MB decomposed Rb-82 cardiac PET images is evaluated using simulated and experimental data. Precision of myocardial blood flow (MBF) measurement is also evaluated. Methods: A gamma-variate model was used to describe the transport of Rb-82 in arterial blood from the right to left ventricle, and a one-compartment model to describe the exchange between blood and myocardium. Simulations of canine and rat heart imaging were performed to evaluate parameter estimation errors. Arterial blood sampling in rats and (CO)-C-11 blood pool imaging in dogs were used to evaluate factor and structure accuracy. Variable infusion duration studies in canine were used to evaluate MB structure and global MBF reproducibility. All results were compared to a previously published minimal structure overlap (MSO) method. Results: Canine heart simulations demonstrated that MB has lower root-mean-square error (RMSE) than MSO for both factor (0.2% vs 0.5%, p<0.001 MB vs MSO, respectively) and structure (3.0% vs 4.7%, p<0.001) estimations, as with rat heart simulations (factors: 0.2% vs 0.9%, p<0.001 and structures: 3.0% vs 6.7%, p<0.001). MB blood factors compared to arterial blood samples in rats had lower RMSE than MSO (1.6% vs 2.2%, p=0.025). There was no difference in the RMSE of blood structures compared to a (CO)-C-11 blood pool image in dogs (8.5% vs 8.8%, p=0.23). Myocardial structures were more reproducible with MB than with MSO (RMSE=3.9% vs 6.2%, p<0.001), as were blood structures (RMSE=4.9% vs 5.6%, p=0.006). Finally, MBF values tended to be more reproducible with MB compared to MSO (CV=10% vs 18%, p=0.16). The execution time of MB was, on average, 2.4 times shorter than MSO (p<0.001) due to fewer free parameters. Conclusions: Kinetic model-based factor analysis can be used to provide physiologically accurate decomposition of Rb-82 dynamic PET images, and may improve the precision of MBF quantification. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3438474]
引用
收藏
页码:3995 / 4010
页数:16
相关论文
共 50 条
  • [11] THE ABILITY OF QUANTITATIVE 82-RUBIDIUM CARDIAC POSITRON TOMOGRAPHY TO DETECT ALTERATIONS IN REGIONAL MYOCARDIAL BLOOD FLOW IN PATIENTS WITH ANGIOGRAPHIC CORONARY STENOSES
    Van Tosh, Andrew
    Faber, Tracy
    Votaw, John R.
    Reichek, Nathaniel
    Palestro, Chris
    Nichols, Kenneth J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E792 - E792
  • [12] Impaired myocardial flow reserve from 82-rubidium positron emission tomography predicts survival benefit from revascularization: a multicenter registry study
    Toftholm, M.
    Hansen, K. W. H. Kim Wadt
    Hoejstrup, S. H. Signe
    Bjerking, L. H. B. Louise Hougesen
    Galatius, S. G. Soeren
    Bouchelouche, K. B. Kirsten
    Jakobsen, L. J. Lars
    Christiansen, E. H. C. Evald Hoej
    Marner, L. M. Lisbeth
    Talleruphuus, U. T. Ulrik
    Prescott, E. I. B. P. Eva Irene Bossano
    EUROPEAN HEART JOURNAL, 2023, 44
  • [13] PROGNOSTIC VALUE OF RUBIDIUM-82 POSITRON EMISSION TOMOGRAPHY FOR EVALUATION OF PATIENTS FOLLOWING CARDIAC TRANSPLANTATION
    McArdle, B. A.
    Davies, R.
    Small, G.
    Yam, Y.
    Haddad, H.
    Mielniczuk, L.
    Stadnick, E.
    Guo, A.
    Beanlands, R.
    Dekemp, R.
    Chow, B.
    CANADIAN JOURNAL OF CARDIOLOGY, 2013, 29 (10) : S138 - S138
  • [14] Assessment of Coronary Vasoreactivity by Multidetector Computed Tomography - Feasibility Study With Rubidium-82 Cardiac Positron Emission Tomography
    Dunet, Vincent
    Qanadli, Salah D.
    Allenbach, Gilles
    Dabiri, Amin
    Mazzolai, Lucia
    Waeber, Bernard
    Feihl, Francois
    Prior, John O.
    CIRCULATION JOURNAL, 2012, 76 (01) : 160 - 167
  • [15] Coronary Microvascular Disease Assessed by 82-Rubidium Positron Emission Tomography Myocardial Perfusion Imaging Is Associated With Small Vessel Disease of the Kidney and Brain
    Hojstrup, Signe
    Hansen, Kim W.
    Talleruphuus, Ulrik
    Marner, Lisbeth
    Galatius, Soren
    Rauf, Maira
    Bjerking, Louise H.
    Jakobsen, Lars
    Christiansen, Evald H.
    Bouchelouche, Kirsten
    Christensen, Hanne
    Prescott, Eva I. B.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2023, 12 (12):
  • [16] Cardiac Rubidium-82 Positron Emission Tomography as an 'Area at Risk' Marker. Comparison to the Gold Standard, Cardiac SPECT
    Ghotbi, Adam A.
    Hasbak, Philip
    Christensen, Thomas
    Engstrom, Thomas
    Kelbaek, Henning
    Kjaer, Andreas
    CIRCULATION, 2014, 130
  • [17] Prognostic value of myocardial flow reserve obtained by 82-rubidium positron emission tomography in long-term follow-up after heart transplantation
    Lærke Marie Nelson
    Thomas Emil Christensen
    Kasper Rossing
    Philip Hasbak
    Finn Gustafsson
    Journal of Nuclear Cardiology, 2022, 29 : 2555 - 2567
  • [18] Prognostic value of myocardial flow reserve obtained by 82-rubidium positron emission tomography in long-term follow-up after heart transplantation
    Nelson, Laerke Marie
    Christensen, Thomas Emil
    Rossing, Kasper
    Hasbak, Philip
    Gustafsson, Finn
    JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (05) : 2555 - 2567
  • [19] Rubidium-82 positron emission tomography for detection of acute doxorubicin-induced cardiac effects in lymphoma patients
    Adam Høgsbro Laursen
    Marie Bayer Elming
    Rasmus Sejersten Ripa
    Philip Hasbak
    Andreas Kjær
    Lars Køber
    Jacob Louis Marott
    Jens Jakob Thune
    Martin Hutchings
    Journal of Nuclear Cardiology, 2020, 27 : 1698 - 1707
  • [20] Myocardial creep and cardiorespiratory motion correction improves diagnostic accuracy of Rubidium-82 cardiac positron emission tomography
    Lassen, Martin Lyngby
    Rasmussen, Thomas
    Byrne, Christina
    Holmvang, Lene
    Kjaer, Andreas
    Hasbak, Philip
    JOURNAL OF NUCLEAR CARDIOLOGY, 2023, 30 (06) : 2289 - 2300