Three-phase hollow fiber microextraction based on two immiscible organic solvents for determination of tricyclic antidepressant drugs: Comparison with conventional three-phase hollow fiber microextraction

被引:61
|
作者
Ghambarian, Mahnaz [1 ]
Yamini, Yadollah [1 ]
Esrafili, Ali [1 ]
机构
[1] Tarbiat Modares Univ, Fac Sci, Dept Chem, Tehran, Iran
关键词
Hollow fiber based microextraction; Tricyclic antidepressant drugs; High performance liquid chromatography-diode array detector; Gas chromatography-mass spectrometry; PERFORMANCE LIQUID-CHROMATOGRAPHY; SOLID-PHASE MICROEXTRACTION; SUPERCRITICAL-FLUID EXTRACTION; MICROWAVE-ASSISTED EXTRACTION; TANDEM MASS-SPECTROMETRY; SAMPLE PREPARATION; BIOLOGICAL-FLUIDS; HUMAN PLASMA; HUMAN SERUM; AMITRIPTYLINE;
D O I
10.1016/j.chroma.2011.11.055
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The aim of this research was to compare the extraction efficiencies of two modes of three-phase hollow fiber microextraction (HF-LLLME) based on aqueous and organic acceptor phases for analysis of tricyclic antidepressant (TCA) drugs. High-performance liquid chromatography with photodiode array detection (HPLC-DAD) was applied for determination of the drugs. In order to examine the ability of the new concept of HF-LLLME based on organic acceptor solvent in comparison with aqueous acceptor phase to extract the analytes, four TCAs were selected. The effect of different extraction conditions (i.e., type of acceptor phase, hollow fiber length, ionic strength, stirring rate, and extraction time) on the extraction efficiency of the TCAs was investigated and optimized using central composite design (CCD) as a powerful tool. Both methods were characterized by good linearity and high repeatability, but HF-LLLME with organic acceptor provided higher extraction efficiency and thus lower limits of detection (LODs). Calibration curves were linear (r(2) > 0.996) in the range of 0.2-20014 mu g L-1. LODs for all the TCAs ranged from 0.08 to 0.2 mu g L-1 using HPLC-DAD. Also an improvement in sensitivity of several orders of magnitude was achieved using single-ion monitoring GC-MS analyses (0.04 mu g L-1) due to compatibility of this technique with GC instrument. The applicability of the proposed HF-LLLME/GC-MS and HPLC-DAD methods was demonstrated by analyzing the drugs in spiked urine and plasma samples. The obtained recoveries of the drugs in the range of 87.9-109.2% indicated the excellent capability of the developed method for extraction of TCAs from complex matrices. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:5 / 12
页数:8
相关论文
共 50 条
  • [41] Hollow fiber-liquid phase microextraction combined with gas chromatography for the determination of phenothiazine drugs in urine
    Xiao, Qin
    Hu, Bin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (19): : 1599 - 1604
  • [42] Three-phase carrier-mediated hollow fiber microextraction based on deep eutectic solvent followed by HPLC-UV for determination of raloxifene and ethinylestradiol in pharmaceutical wastewater treatment plants
    Seidi, Shahram
    Alavi, Leila
    Jabbari, Ali
    Shanehsaz, Maryam
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2019, 16 (05) : 1007 - 1018
  • [43] Three-phase liquid-phase microextraction of weakly basic drugs from whole blood
    Ugland, HG
    Krogh, M
    Reubsaet, L
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 798 (01): : 127 - 135
  • [44] Covalent organic framework reinforced hollow fiber for solid-phase microextraction and determination of pesticides in foods
    Li, Wen-kui
    Xue, Yuan-ji
    Fu, Xiang-yun
    Ma, Zhi-qing
    Feng, Jun-tao
    FOOD CONTROL, 2022, 133
  • [45] A three phase hollow fiber liquid-phase microextraction for quantification of lamotrigine in plasma of epileptic patients by capillary electrophoresis
    Ribeiro Barros, Luiza Saldanha
    Carrao, Daniel Blascke
    Costa Queiroz, Regina Helena
    Moraes de Oliveira, Anderson Rodrigo
    de Gaitani, Cristiane Masetto
    ELECTROPHORESIS, 2016, 37 (20) : 2678 - 2684
  • [46] Pressure drops and hydraulic resistances in a three-phase hollow fiber membrane contactor with frame elements
    Vladisavljevic, GT
    Mitrovic, MV
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2001, 40 (01) : 3 - 11
  • [47] Developments in hollow fiber based liquid-phase microextraction: principles and applications
    Mahnaz Ghambarian
    Yadollah Yamini
    Ali Esrafili
    Microchimica Acta, 2012, 177 : 271 - 294
  • [48] Developments in hollow fiber based liquid-phase microextraction: principles and applications
    Ghambarian, Mahnaz
    Yamini, Yadollah
    Esrafili, Ali
    MICROCHIMICA ACTA, 2012, 177 (3-4) : 271 - 294
  • [49] Supramolecular solvent-based hollow fiber liquid phase microextraction of benzodiazepines
    Rezaei, Fatemeh
    Yamini, Yadollah
    Moradi, Morteza
    Daraei, Bahram
    ANALYTICA CHIMICA ACTA, 2013, 804 : 135 - 142
  • [50] Two-phase and three-phase liquid-phase microextraction of hydrochlorothiazide and triamterene in urine samples
    Panahi, Homayon Ahmad
    Ejlali, Maryam
    Chabouk, Monireh
    BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (07) : 1022 - 1028