Three-phase hollow fiber microextraction based on two immiscible organic solvents for determination of tricyclic antidepressant drugs: Comparison with conventional three-phase hollow fiber microextraction

被引:61
|
作者
Ghambarian, Mahnaz [1 ]
Yamini, Yadollah [1 ]
Esrafili, Ali [1 ]
机构
[1] Tarbiat Modares Univ, Fac Sci, Dept Chem, Tehran, Iran
关键词
Hollow fiber based microextraction; Tricyclic antidepressant drugs; High performance liquid chromatography-diode array detector; Gas chromatography-mass spectrometry; PERFORMANCE LIQUID-CHROMATOGRAPHY; SOLID-PHASE MICROEXTRACTION; SUPERCRITICAL-FLUID EXTRACTION; MICROWAVE-ASSISTED EXTRACTION; TANDEM MASS-SPECTROMETRY; SAMPLE PREPARATION; BIOLOGICAL-FLUIDS; HUMAN PLASMA; HUMAN SERUM; AMITRIPTYLINE;
D O I
10.1016/j.chroma.2011.11.055
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The aim of this research was to compare the extraction efficiencies of two modes of three-phase hollow fiber microextraction (HF-LLLME) based on aqueous and organic acceptor phases for analysis of tricyclic antidepressant (TCA) drugs. High-performance liquid chromatography with photodiode array detection (HPLC-DAD) was applied for determination of the drugs. In order to examine the ability of the new concept of HF-LLLME based on organic acceptor solvent in comparison with aqueous acceptor phase to extract the analytes, four TCAs were selected. The effect of different extraction conditions (i.e., type of acceptor phase, hollow fiber length, ionic strength, stirring rate, and extraction time) on the extraction efficiency of the TCAs was investigated and optimized using central composite design (CCD) as a powerful tool. Both methods were characterized by good linearity and high repeatability, but HF-LLLME with organic acceptor provided higher extraction efficiency and thus lower limits of detection (LODs). Calibration curves were linear (r(2) > 0.996) in the range of 0.2-20014 mu g L-1. LODs for all the TCAs ranged from 0.08 to 0.2 mu g L-1 using HPLC-DAD. Also an improvement in sensitivity of several orders of magnitude was achieved using single-ion monitoring GC-MS analyses (0.04 mu g L-1) due to compatibility of this technique with GC instrument. The applicability of the proposed HF-LLLME/GC-MS and HPLC-DAD methods was demonstrated by analyzing the drugs in spiked urine and plasma samples. The obtained recoveries of the drugs in the range of 87.9-109.2% indicated the excellent capability of the developed method for extraction of TCAs from complex matrices. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:5 / 12
页数:8
相关论文
共 50 条
  • [21] Determination of three plant growth regulators in Dendrobium officinale and Anoectochilus roxburghii by three-phase hollow fiber liquid phase microextraction-high performance liquid chromatography
    Wu Pingping
    Lin Renyi
    Huang Liying
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2023, 41 (08) : 683 - 689
  • [22] Optimization of carrier-mediated three-phase hollow fiber microextraction combined with HPLC-UV for determination of propylthiouracil in biological samples
    Ebrahimzadeh, Homeira
    Asgharinezhad, Ali Akbar
    Abedi, Hamid
    Kamarei, Fahimeh
    TALANTA, 2011, 85 (02) : 1043 - 1049
  • [23] Hollow-Fibre Liquid-Phase Microextraction in the Three-Phase Mode - Practical Considerations
    Gjelstad, Astrid
    Taherkhani, Hamidreza
    Rasmussen, Knut Einar
    Pederson-Bjergaard, Stig
    Majors, Ronald E.
    LC GC EUROPE, 2011, 24 (12) : 633 - +
  • [24] Three-phase hollow fiber liquid-phase microextraction combined with HPLC for determination of three trace acidic plant growth regulators in Anoectochilus roxburghii (Wall.) Lindl
    Hong, Ruixia
    Wu, Pingping
    Lin, Jin
    Huang, Liying
    Yang, Lijuan
    Wu, Youjia
    Yao, Hong
    JOURNAL OF SEPARATION SCIENCE, 2020, 43 (14) : 2773 - 2783
  • [25] Three-phase hollow fiber liquid-phase microextraction based on a magnetofluid for the analysis of aristolochic acids in plasma by high-performance liquid chromatography
    Song, Rui Juan
    Pu, Feng Ping
    Zhou, Jun
    Sun, Jiang Bing
    Zeng, Ping
    Zhang, Qiong
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (13) : 1622 - 1631
  • [26] Two-phase hollow fiber liquid-phase microextraction
    Esrafili, Ali
    Baharfar, Mahroo
    Tajik, Mohammad
    Yamini, Yadollah
    Ghambarian, Mahnaz
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2018, 108 : 314 - 322
  • [27] Deep eutectic solvent as the acceptor phase in three-phase hollow fiber liquid-phase microextraction for the determination of pyrethroid insecticides from environmental water samples prior to HPLC
    Ezoddin, Maryam
    Naraki, Karim
    Abdi, Khosrou
    Kakavandi, Nader Rahimi
    Ghazi-Khansari, Mahmoud
    Javadi, Mahdiyeh H. S.
    Pirooznia, Nazanin
    BIOMEDICAL CHROMATOGRAPHY, 2022, 36 (11)
  • [28] Three-phase hollow-fiber liquid-phase microextraction combined with HPLC-UV for the determination of isothiazolinone biocides in adhesives used for food packaging materials
    Rosero-Moreano, Milton
    Canellas, Elena
    Nerin, Cristina
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (03) : 272 - 280
  • [29] Rapid determination of semi-VOC using partly-immersed three-phase hollow fiber liquid phase microextraction combined with high performance liquid chromatography
    Lin, Hailu
    Yan, Hong
    Luo, Mingbiao
    Peng, Xuejiao
    Liu, Wei
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [30] Advancement of liquid phase microextraction based on porous hollow fiber
    Luo Ming-Biao
    Liu Wei
    Li Bo-Ping
    Yang Zhi
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 35 (07) : 1071 - 1077