Study of the IMRT interplay effect using a 4DCT Monte Carlo dose calculation

被引:10
|
作者
Jensen, Michael D. [1 ]
Abdellatif, Ady [2 ]
Chen, Jeff [1 ,2 ,3 ]
Wong, Eugene [1 ,2 ,3 ,4 ]
机构
[1] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
[2] London Hlth Sci Ctr, London Reg Canc Program, Dept Phys & Engn, London, ON, Canada
[3] Univ Western Ontario, Dept Oncol, London, ON, Canada
[4] Univ Western Ontario, Dept Phys & Astron, London, ON, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2012年 / 57卷 / 08期
关键词
DEFORMABLE IMAGE REGISTRATION; INTRA-FRACTION MOTION; QUALITY-ASSURANCE; VERIFICATION; MANAGEMENT; DOSIMETRY; DELIVERY; BEAM;
D O I
10.1088/0031-9155/57/8/N89
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Respiratory motion may lead to dose errors when treating thoracic and abdominal tumours with radiotherapy. The interplay between complex multileaf collimator patterns and patient respiratory motion could result in unintuitive dose changes. We have developed a treatment reconstruction simulation computer code that accounts for interplay effects by combining multileaf collimator controller log files, respiratory trace log files, 4DCT images and a Monte Carlo dose calculator. Two three-dimensional (3D) IMRT step-and-shoot plans, a concave target and integrated boost were delivered to a 1D rigid motion phantom. Three sets of experiments were performed with 100%, 50% and 25% duty cycle gating. The log files were collected, and five simulation types were performed on each data set: continuous isocentre shift, discrete isocentre shift, 4DCT, 4DCT delivery average and 4DCT plan average. Analysis was performed using 3D gamma analysis with passing criteria of 2%, 2 mm. The simulation framework was able to demonstrate that a single fraction of the integrated boost plan was more sensitive to interplay effects than the concave target. Gating was shown to reduce the interplay effects. We have developed a 4DCT Monte Carlo simulation method that accounts for IMRT interplay effects with respiratory motion by utilizing delivery log files.
引用
收藏
页码:N89 / N99
页数:11
相关论文
共 50 条
  • [21] Conformal treatment planning using 4DCT can decrease ipsilateral lung dose and improve tumor coverage: A prospective 4DCT treatment planning study
    Parikh, P
    Wahab, S
    Lu, W
    Nantz, R
    Hubenschmidt, J
    Nystrom, M
    ElNaqa, I
    Pierburg, B
    Bradley, JD
    Low, DA
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S286 - S287
  • [22] Monte Carlo Calculation of Breathing Interplay Effect and Dose Calculation Discretization Error for VMAT and TomoTherapy Stereotactic Lung Treatments
    Belec, J.
    Ploquin, N.
    Clark, B. G.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [23] Monte Carlo dose computation for IMRT optimization
    Laub, W
    Alber, M
    Birkner, M
    Nüsslin, F
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (07): : 1741 - 1754
  • [24] Validation of Independent IMRT and VMAT Dose Calculation System based on Geant4 Monte Carlo Toolkit
    Choi, H. J.
    Park, H.
    Shin, W. G.
    Kim, J. I.
    Min, C. H.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S942 - S942
  • [25] Evaluation of Lung Dose Using Deformable 4DCT Registration Method
    Li, J.
    Chan, M.
    Hu, Y.
    Burman, C.
    MEDICAL PHYSICS, 2010, 37 (06) : 3324 - +
  • [26] A multi-leaf collimator model for accurate IMRT Monte Carlo dose calculation
    Siebers, J
    Keall, P
    Kim, J
    Mohan, R
    MEDICAL PHYSICS, 2002, 29 (06) : 1316 - 1316
  • [27] Head-and-neck IMRT treatments assessed with a Monte Carlo dose calculation engine
    Seco, J
    Adams, E
    Bidmead, M
    Partridge, M
    Verhaegen, F
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (05): : 817 - 830
  • [28] A Monte Carlo study of the out-of-field dose from IMRT
    Kry, S.
    Salehpour, M.
    Titt, U.
    Stovall, M.
    White, R.
    Followill, D.
    MEDICAL PHYSICS, 2007, 34 (06) : 2406 - 2406
  • [29] Planning design of locally advanced pancreatic carcinoma using 4DCT and IMRT/IGRT technologies
    Sangalli, Giulia
    Passoni, Paolo
    Cattaneo, Giovanni M.
    Broggi, Sara
    Bettinardi, Valentino
    Reni, Michele
    Slim, Najla
    Di Muzio, Nadia
    Calandrino, Riccardo
    ACTA ONCOLOGICA, 2011, 50 (01) : 72 - 80
  • [30] Comparative Study of SBRT Lung Dose Calculation Using Eclipse and Monte Carlo
    Zhan, L.
    Schaly, B.
    Jiang, R.
    Osei, E. K.
    MEDICAL PHYSICS, 2012, 39 (07) : 4621 - 4621