Automatic determination of left ventricular ejection fraction from gated blood-pool tomography

被引:0
|
作者
Vanhove, C [1 ]
Franken, PR [1 ]
Defrise, M [1 ]
Momen, A [1 ]
Everaert, H [1 ]
Bossuyt, A [1 ]
机构
[1] Free Univ Brussels, AZ VUB, Univ Hosp, Div Nucl Med, B-1090 Brussels, Belgium
关键词
blood-pool SPECT; automatic algorithm; left ventricular ejection fraction;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to develop and validate a new algorithm to automatically compute left ventricular ejection fraction (LVEF) from gated blood-pool tomography (GBPT). The results were compared with those of conventional planar radionuclide angiocardiography (PRNA). Methods: Fifty-three consecutive patients received an injection of 740 MBq Tc-99m-labeled human serum albumin. PRNA and GBPT were performed consecutively in a random sequence. PRNA served as the reference, and GBPT images were processed using a new edge detection algorithm. The algorithm is fast (<45 s), fully automatic, and works in three-dimensional space. The method includes identification of the Valve plane and the septum, The left ventricular cavity at end-diastole is delineated by segmentation using an iterative threshold technique. An optimal threshold is reached when the corresponding isocontour best fits the first derivative of the end-diastolic count distribution in three dimensions. This optimal threshold is then applied to delineate the left Ventricular cavity on the other time bins. The data are corrected for the partial-volume effect. Left ventricular Volumes are determined using a geometry-based method and are used to calculate the ejection fraction. Results: The success rate of the new algorithm was 94%, LVEFs calculated from GBPT agreed well with those calculated from PRNA (r = 0.78; GBPT = 0.94 PRNA + 6.33). The systematic error was 2.8%, and the random error was 8.8%. Excellent inter- and intraobserver reproducibility was found, with average differences of 1.1% +/- 4.6% and 1.1% +/- 5.0%, respectively, between the two measurements. Conclusion: This new algorithm provides a fast, automated, and objective method to calculate LVEF from GBPT.
引用
收藏
页码:401 / 407
页数:7
相关论文
共 50 条
  • [41] CLINICAL VALIDATION OF FULLY AUTOMATED COMPUTATION OF EJECTION FRACTION FROM GATED EQUILIBRIUM BLOOD-POOL SCINTIGRAMS
    REIBER, JHC
    LIE, SP
    SIMOONS, ML
    HOEK, C
    GERBRANDS, JJ
    WIJNS, W
    BAKKER, WH
    KOOIJ, PPM
    JOURNAL OF NUCLEAR MEDICINE, 1983, 24 (12) : 1099 - 1107
  • [42] Comparative values of gated blood-pool SPECT and CMR for ejection fraction and volume estimation
    Sibille, Louis
    Ben Bouallegue, Faycal
    Bourdon, Aurelie
    Micheau, Antoine
    Vernhet-Kovacsik, Helene
    Mariano-Goulart, Denis
    NUCLEAR MEDICINE COMMUNICATIONS, 2011, 32 (02) : 121 - 128
  • [43] Evaluation of left and right ventricular ejection fraction and volumes from gated blood-pool SPECT in patients with dilated cardiomyopathy comparison with cardiac magnetic resonance imaging
    Xie, Bo-Qia
    Tian, Yue-Qin
    Zhang, Jian
    Kang, Lian-Ming
    Zhao, Shi-Hua
    Lu, Min-Jie
    Yang, Min-Fu
    Wang, Dao-Yu
    Guo, Feng
    He, Zuo-Xiang
    CARDIOLOGY, 2011, 120 : 60 - 60
  • [44] Left and right ventricular volumes and ejection fraction in mice using ECG gated pinhole gated blood pool SPECT
    Lahoutte, T
    Vanhove, C
    Bossuyt, A
    Franken, PR
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S260 - S260
  • [45] Validation of Gated Blood-Pool SPECT Regional Left Ventricular Function Measurements
    Nichols, Kenneth J.
    Van Tosh, Andrew
    Wang, Yi
    Palestro, Christopher J.
    Reichek, Nathaniel
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (01) : 53 - 60
  • [46] Left ventricular ejection fraction determination using planar gated blood pool: comparing four different operator's results
    Martins, M. A. C. S.
    Cardoso, M. D. M.
    Parracho, M. M. L.
    Conde, F. M. P. B.
    Ferreira, I. A. C. Q.
    Ferrer-Antunes, A. A.
    de Lima, J. M. C. Pedroso
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S380 - S380
  • [47] LEFT-VENTRICULAR EJECTION FRACTION - PHYSICIAN ESTIMATES COMPARED WITH GATED BLOOD POOL SCAN MEASUREMENTS
    EAGLE, KA
    QUERTERMOUS, T
    SINGER, DE
    MULLEY, AG
    REDER, VA
    BOUCHER, CA
    STRAUSS, HW
    THIBAULT, GE
    ARCHIVES OF INTERNAL MEDICINE, 1988, 148 (04) : 882 - 885
  • [48] Accuracy and reproducibility of left and right ventricular ejection fraction assessed by automatic evaluation of ECG-gated blood pool SPECT.
    Higuchi, T
    Taki, J
    Nakajima, K
    Kinuya, S
    Tonami, N
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 97P - 97P
  • [49] Left ventricular ejection fraction calculation with egg-gated blood pool tomography: Is activity ratio better than volume ratio?
    Daou, D
    Vilain, D
    Coaguila, C
    Helal, BO
    Fourme, T
    Slama, M
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 136P - 136P
  • [50] GEOMETRIC DETERMINATION OF LEFT-VENTRICULAR VOLUME FROM GATED BLOOD-POOL STUDIES USING A SLANT-HOLE COLLIMATOR
    UREN, RF
    NEWMAN, HN
    HUTTON, BF
    CORMACK, J
    BERNSTEIN, L
    ALLEN, L
    DYER, I
    RADIOLOGY, 1983, 147 (02) : 541 - 545