Automatic determination of left ventricular ejection fraction from gated blood-pool tomography

被引:0
|
作者
Vanhove, C [1 ]
Franken, PR [1 ]
Defrise, M [1 ]
Momen, A [1 ]
Everaert, H [1 ]
Bossuyt, A [1 ]
机构
[1] Free Univ Brussels, AZ VUB, Univ Hosp, Div Nucl Med, B-1090 Brussels, Belgium
关键词
blood-pool SPECT; automatic algorithm; left ventricular ejection fraction;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to develop and validate a new algorithm to automatically compute left ventricular ejection fraction (LVEF) from gated blood-pool tomography (GBPT). The results were compared with those of conventional planar radionuclide angiocardiography (PRNA). Methods: Fifty-three consecutive patients received an injection of 740 MBq Tc-99m-labeled human serum albumin. PRNA and GBPT were performed consecutively in a random sequence. PRNA served as the reference, and GBPT images were processed using a new edge detection algorithm. The algorithm is fast (<45 s), fully automatic, and works in three-dimensional space. The method includes identification of the Valve plane and the septum, The left ventricular cavity at end-diastole is delineated by segmentation using an iterative threshold technique. An optimal threshold is reached when the corresponding isocontour best fits the first derivative of the end-diastolic count distribution in three dimensions. This optimal threshold is then applied to delineate the left Ventricular cavity on the other time bins. The data are corrected for the partial-volume effect. Left ventricular Volumes are determined using a geometry-based method and are used to calculate the ejection fraction. Results: The success rate of the new algorithm was 94%, LVEFs calculated from GBPT agreed well with those calculated from PRNA (r = 0.78; GBPT = 0.94 PRNA + 6.33). The systematic error was 2.8%, and the random error was 8.8%. Excellent inter- and intraobserver reproducibility was found, with average differences of 1.1% +/- 4.6% and 1.1% +/- 5.0%, respectively, between the two measurements. Conclusion: This new algorithm provides a fast, automated, and objective method to calculate LVEF from GBPT.
引用
收藏
页码:401 / 407
页数:7
相关论文
共 50 条
  • [21] Left ventricular ejection fraction and volumes from gated blood pool tomographies: A comparison between two automatic algorithms
    Vanhove, C
    Walgraeve, N
    Everaert, H
    Franken, PR
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 1038 - 1038
  • [22] Left Ventricular Ejection Fraction in gated blood pool imaging: sources of variation
    Knudsen, K.
    Arveschoug, A. K.
    Staanum, P. F.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S376 - S376
  • [23] VALIDITY OF DIFFERENT GATED EQUILIBRIUM BLOOD POOL METHODS FOR DETERMINATION OF LEFT-VENTRICULAR EJECTION FRACTION
    KARSCH, KR
    SCHICHA, H
    RENTROP, P
    KREUZER, H
    EMRICH, D
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1980, 5 (05): : 439 - 445
  • [24] European variability of left ventricular ejection fraction from gated blood pool studies.
    Franken, PR
    Deconinck, F
    Bourguignon, MH
    Sokole, EB
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 725 - 725
  • [25] CONSIDERATIONS IN CALCULATION OF LEFT-VENTRICULAR EJECTION FRACTION FROM GATED BLOOD POOL STUDIES
    FOLEY, MJ
    SPIES, SM
    INVESTIGATIVE RADIOLOGY, 1981, 16 (05) : 400 - 400
  • [26] Electrocardiographically gated blood-pool SPECT and left ventricular function: Comparative value of 3 methods for ejection fraction and volume estimation
    Daou, D
    Harel, F
    Helal, BO
    Fourme, T
    Colin, P
    Lebtahi, R
    Mariano-Goulart, D
    Faraggi, M
    Slama, M
    Le Guludec, D
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (07) : 1043 - 1049
  • [27] Evaluation of Left and Right Ventricular Ejection Fraction and Volumes from Gated Blood-Pool SPECT in Patients with Dilated Cardiomyopathy: Comparison with Cardiac MRI
    Xie, Bo-Qia
    Tian, Yue-Qin
    Zhang, Jian
    Zhao, Shi-Hua
    Yang, Min-Fu
    Guo, Feng
    Wang, Dao-Yu
    Wei, Hong-Xing
    Chu, Ke-Wei
    He, Zuo-Xiang
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (04) : 584 - 591
  • [28] Automatic quantification of left and right ventricular ejection fractions from gated blood pool SPECT
    Van Kriekinge, SD
    Berman, DS
    Germano, G
    CIRCULATION, 1999, 100 (18) : 26 - 26
  • [29] Gated blood pool SPECT for measurement of left ventricular volumes and left ventricular ejection fraction: comparison of 8 and 16 frame gated blood pool SPECT
    Seong-Jang Kim
    In-Ju Kim
    Yun-Seong Kim
    Yong-Ki Kim
    The International Journal of Cardiovascular Imaging, 2005, 21 : 261 - 266
  • [30] Gated blood pool SPECT for measurement of left ventricular volumes and left ventricular ejection fraction: comparison of 8 and 16 frame gated blood pool SPECT
    Kim, SJ
    Kim, IJ
    Kim, YS
    Kim, YK
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2005, 21 (2-3): : 261 - 266