A hybrid technique for spectroscopic imaging with reduced truncation artifact

被引:21
|
作者
Metzger, G [1 ]
Sarkar, S [1 ]
Zhang, XD [1 ]
Heberlein, K [1 ]
Patel, M [1 ]
Hu, XP [1 ]
机构
[1] Univ Minnesota, Sch Med, Dept Radiol, Minneapolis, MN 55345 USA
关键词
MRS; spectroscopic imaging; echo-planar; truncation artifact;
D O I
10.1016/S0730-725X(98)00187-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Traditionally, Fourier spectroscopic imaging is associated with a small k-space coverage which leads to truncation artifacts such as "bleeding" and ringing in the resultant image. Because substantial truncation artifacts mainly arise from regions having intense signals, such as the subcutaneous lipid in the head, effective reduction of truncation artifacts can be achieved by obtaining an extended k-space coverage for these regions, In this paper, a hybrid technique which employs phase-encoded spectroscopic imaging (SI) to cover the central portion of the k-space and echo-planar spectroscopic imaging (EPSI) to measure the peripheral portion of the k-space is developed, EPSI, despite its inherently low SNR characteristics, provides a sufficient SNR for outer high-spatial frequency components of the aforementioned high signal regions and supplies an extended k-space coverage of these regions for the reduction of truncation artifacts. The data processing includes steps designed to remove inconsistency between the two types of data and a previously described technique for selectively retaining only outer k-space information for the high signal regions during the reconstruction. Experimental studies, in both phantoms and normal volunteers, demonstrate that the hybrid technique provides significant reduction in truncation artifacts, (C) 1999 Elsevier Science Inc.
引用
收藏
页码:435 / 443
页数:9
相关论文
共 50 条
  • [1] The truncation artifact
    Brian Wosnitzer
    Ramesh Gadiraju
    Gordon DePuey
    Journal of Nuclear Cardiology, 2011, 18 : 187 - 191
  • [2] BOUNDARY ARTIFACT DUE TO TRUNCATION ERRORS IN MR IMAGING
    LUFKIN, RB
    PUSEY, E
    STARK, DD
    BROWN, R
    LEIKIND, B
    HANAFEE, WN
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 147 (06) : 1283 - 1287
  • [3] The truncation artifact
    Wosnitzer, Brian
    Gadiraju, Ramesh
    DePuey, Gordon
    JOURNAL OF NUCLEAR CARDIOLOGY, 2011, 18 (01) : 187 - 191
  • [4] Truncation artifact reduction in spectroscopic imaging using a dual-density spiral k-space trajectory
    Sarkar, S
    Heberlein, K
    Hu, XP
    MAGNETIC RESONANCE IMAGING, 2002, 20 (10) : 743 - 757
  • [5] TECHNIQUE FOR REDUCTION OF TRUNCATION ARTIFACT IN CHEMICAL-SHIFT IMAGES
    HU, XP
    STILLMAN, AE
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (03) : 290 - 294
  • [6] An improved method for reduction of truncation artifact in magnetic resonance imaging
    Lee, SJ
    APPLICATIONS OF DIGITAL IMAGE PROCESSING XXI, 1998, 3460 : 587 - 598
  • [7] Truncation artifact in dynamic MR imaging for small adrenal mass
    Kanematsu, M
    Hoshi, H
    Yokoyama, R
    Tanahashi, T
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (04) : 1070 - 1070
  • [8] TRUNCATION ARTIFACT - A POTENTIAL PITFALL IN MR-IMAGING OF THE MENISCI OF THE KNEE
    TURNER, DA
    RAPOPORT, MI
    ERWIN, WD
    MCGOULD, M
    SILVERS, RI
    RADIOLOGY, 1991, 179 (03) : 629 - 633
  • [9] Truncation artifact reduction in magnetic resonance imaging by Markov random field methods
    Istituto per le Applicazioni del, Calcolo, Roma, Italy
    IEEE Trans Med Imaging, 3 (434-441):
  • [10] Truncation artifact and boundary artifact reduction in breast tomosynthesis reconstruction
    Zhang, Yiheng
    Chan, Heang-Ping
    Wu, Yi-Ta
    Sahiner, Berkman
    Zhou, Chuan
    Wei, Jun
    Ge, Jun
    Hadjiiski, Lubomir M.
    Shi, Jiazheng
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913