TECHNIQUE FOR REDUCTION OF TRUNCATION ARTIFACT IN CHEMICAL-SHIFT IMAGES

被引:22
|
作者
HU, XP
STILLMAN, AE
机构
[1] Department of Radiology, University of Minnesota, Minneapolis, MN
关键词
D O I
10.1109/42.97578
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We describe a technique to reduce truncation artifacts in chemical shift images by using boundary information available from anatomic images. In this approach, high spatial frequency components are extrapolated from the observed data by making use of the boundary information. This technique has been tested with simulations and phantom experiments. Results obtained show that the technique works very well. In this paper, we present the technical details of and results of computer simulations and phantom studies.
引用
收藏
页码:290 / 294
页数:5
相关论文
共 50 条
  • [1] A ROBUST ALGORITHM FOR REDUCTION OF TRUNCATION ARTIFACT IN CHEMICAL-SHIFT IMAGES
    PATEL, MAS
    HU, XP
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (04) : 812 - 818
  • [2] CHEMICAL-SHIFT ARTIFACT IN CLINICAL MAGNETIC-RESONANCE IMAGES AT 0.35 T
    WEINREB, JC
    BRATEMAN, L
    BABCOCK, EE
    MARAVILLA, KR
    COHEN, JM
    HORNER, SD
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 145 (01) : 183 - 185
  • [3] CHEMICAL-SHIFT ARTIFACT CORRECTION SCHEME USING ECHO-TIME ENCODING TECHNIQUE
    CHO, ZH
    NALCIOGLU, O
    PARK, HW
    RA, JB
    HILAL, SK
    MAGNETIC RESONANCE IN MEDICINE, 1985, 2 (03) : 253 - 261
  • [4] CHEMICAL-SHIFT ENCODING IN NMR IMAGES
    MARTIN, JF
    WADE, CG
    JOURNAL OF MAGNETIC RESONANCE, 1985, 61 (01) : 153 - 157
  • [5] REDUCTION OF TRUNCATION ARTIFACTS IN CHEMICAL-SHIFT IMAGING BY EXTENDED SAMPLING USING VARIABLE REPETITION TIME
    HU, XP
    PATEL, M
    CHEN, W
    UGURBIL, K
    JOURNAL OF MAGNETIC RESONANCE SERIES B, 1995, 106 (03): : 292 - 296
  • [6] CHEMICAL-SHIFT ARTIFACT ALONG THE SECTION-SELECT AXIS
    WACHSBERG, RH
    MITCHELL, DG
    RIFKIN, MD
    VINITSKI, S
    TASCIYAN, TA
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (05): : 589 - 591
  • [7] EDGE ARTIFACTS IN MR IMAGES - CHEMICAL-SHIFT EFFECT
    BABCOCK, EE
    BRATEMAN, L
    WEINREB, JC
    HORNER, SD
    NUNNALLY, RL
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (02) : 252 - 257
  • [8] CHEMICAL-SHIFT CHEMICAL-SHIFT CORRELATION SPECTROSCOPY IN POWDERED SOLIDS
    HUGHES, CD
    SHERWOOD, MH
    ALDERMAN, DW
    GRANT, DM
    JOURNAL OF MAGNETIC RESONANCE SERIES A, 1993, 102 (01) : 58 - 72
  • [9] A 2-DIMENSIONAL TECHNIQUE FOR CHEMICAL-SHIFT RESOLUTION IN ONE-DIMENSIONAL NMR IMAGES
    MCCAIN, DC
    WESTLER, WM
    MARKLEY, JL
    JOURNAL OF MAGNETIC RESONANCE, 1991, 93 (01): : 181 - 183
  • [10] Subchondral bone and cartilage thickness from MRI: effects of chemical-shift artifact
    Chris A. McGibbon
    Jenny Bencardino
    William E. Palmer
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2003, 16 : 1 - 9