A hybrid technique for spectroscopic imaging with reduced truncation artifact

被引:21
|
作者
Metzger, G [1 ]
Sarkar, S [1 ]
Zhang, XD [1 ]
Heberlein, K [1 ]
Patel, M [1 ]
Hu, XP [1 ]
机构
[1] Univ Minnesota, Sch Med, Dept Radiol, Minneapolis, MN 55345 USA
关键词
MRS; spectroscopic imaging; echo-planar; truncation artifact;
D O I
10.1016/S0730-725X(98)00187-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Traditionally, Fourier spectroscopic imaging is associated with a small k-space coverage which leads to truncation artifacts such as "bleeding" and ringing in the resultant image. Because substantial truncation artifacts mainly arise from regions having intense signals, such as the subcutaneous lipid in the head, effective reduction of truncation artifacts can be achieved by obtaining an extended k-space coverage for these regions, In this paper, a hybrid technique which employs phase-encoded spectroscopic imaging (SI) to cover the central portion of the k-space and echo-planar spectroscopic imaging (EPSI) to measure the peripheral portion of the k-space is developed, EPSI, despite its inherently low SNR characteristics, provides a sufficient SNR for outer high-spatial frequency components of the aforementioned high signal regions and supplies an extended k-space coverage of these regions for the reduction of truncation artifacts. The data processing includes steps designed to remove inconsistency between the two types of data and a previously described technique for selectively retaining only outer k-space information for the high signal regions during the reconstruction. Experimental studies, in both phantoms and normal volunteers, demonstrate that the hybrid technique provides significant reduction in truncation artifacts, (C) 1999 Elsevier Science Inc.
引用
收藏
页码:435 / 443
页数:9
相关论文
共 50 条
  • [41] TRUNCATION ARTIFACT IN MAGNETIC RESONANCE IMAGES OF THE CANINE SPINAL CORD
    Gregori, Tommaso
    Lam, Richard
    Priestnall, Simon L.
    Lamb, Christopher R.
    VETERINARY RADIOLOGY & ULTRASOUND, 2016, 57 (06) : 582 - 586
  • [42] The magic angle effect: A source of artifact, determinant of image contrast, and technique for imaging
    Bydder, Mark
    Rahal, Andres
    Fullerton, Gary D.
    Bydder, Graerne M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (02) : 290 - 300
  • [43] Hybrid block truncation coding
    Huang, CS
    Lin, YY
    IEEE SIGNAL PROCESSING LETTERS, 1997, 4 (12) : 328 - 330
  • [44] STABILITY OF REDUCED MODEL OBTAINED BY TRUNCATION
    YEUNG, KS
    ELECTRONICS LETTERS, 1981, 17 (11) : 374 - 375
  • [45] A keyhole echo planar hybrid imaging technique
    Paul R. Harvey
    Magnetic Resonance Materials in Physics, Biology and Medicine, 1999, 9 : 16 - 20
  • [46] A keyhole echo planar hybrid imaging technique
    Harvey, Paul R.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 1999, 9 (1-2) : 16 - 20
  • [47] EEG ARTIFACT REMOVAL AND NOISE SUPPRESSION USING HYBRID GLCT-ICA TECHNIQUE
    Jindal, K.
    Upadhyay, R.
    Singh, H. S.
    2018 10TH INTERNATIONAL CONGRESS ON ULTRA MODERN TELECOMMUNICATIONS AND CONTROL SYSTEMS AND WORKSHOPS (ICUMT 2018): EMERGING TECHNOLOGIES FOR CONNECTED SOCIETY, 2018,
  • [48] Reduced depth of field in incoherent hybrid imaging systems
    Sherif, SS
    Cathey, WT
    APPLIED OPTICS, 2002, 41 (29) : 6062 - 6074
  • [49] Truncation artifact correction of attenuation map with iterative and model based reconstruction
    Guillemaud, R
    Hugonnard, P
    Sauze, R
    Grangeat, P
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1212 - 1216
  • [50] A ROBUST ALGORITHM FOR REDUCTION OF TRUNCATION ARTIFACT IN CHEMICAL-SHIFT IMAGES
    PATEL, MAS
    HU, XP
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (04) : 812 - 818