On-line Turn-to-Turn Protection Method of the Synchronous Machines Field Winding

被引:0
|
作者
Tian, Pengfei [1 ]
Platero, Carlos A. [1 ]
Gyftakis, Konstantinos N. [2 ]
机构
[1] Univ Politecn Madrid, Dept Elect Engn, Escuela Tecn Super Ingn Ind, Madrid 28006, Spain
[2] Univ Edinburgh, Sch Engn, Edinburgh, Midlothian, Scotland
关键词
Condition monitoring; Power generation protection; Synchronous generator; Turn-to-turn fault;
D O I
10.1109/demped.2019.8864853
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Turn-to-turn faults are quite common in the synchronous generator field winding, especially in the turbo-generator types. This condition may be caused by either the double- ground fault of the winding or by a lack of insulation between adjacent turns. This paper presents a new on-line protection method for turn-to-turn faults in field windings of synchronous machines with static excitation system. The proposed method is based on the comparison of the measured excitation current with the theoretical excitation current calculated from the stator voltages and currents for the actual operation point. The method has been validated by experimental results using a special laboratory synchronous machine.
引用
收藏
页码:69 / 74
页数:6
相关论文
共 50 条
  • [21] Turn-to-Turn Converter Stress Impact on the Lifetime of Rotating Machines
    Rumi, Alberto
    Cavallini, Andrea
    2023 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, CEIDP, 2023,
  • [22] The mechanism of turn-to-turn capacitance in inductance winding and its calculation methods
    Chen, YP
    Liu, HJ
    Kong, HY
    POWERCON 2002: INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS 1-4, PROCEEDINGS, 2002, : 2173 - 2178
  • [23] Effective Mathematical Model of Synchronous Machine with Turn-to-turn Short-circuit of Rotor Winding for Adaptive Methods of Identification
    Polishchuk, V., I
    Baratova, K., V
    2019 INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING, APPLICATIONS AND MANUFACTURING (ICIEAM), 2019,
  • [24] PROTECTION AGAINST CATCHING FIRE OF PERMANENT MAGNET SYNCHRONOUS MOTORS (PMSM) DURING TURN-TO-TURN FAULTS
    Vorshevskiy, Alexander A.
    Klintsevich, Vyacheslav Y.
    Kornev, Alexander Sergeevich
    Mikhailov, Valery M.
    Senkov, Alexey P.
    MARINE INTELLECTUAL TECHNOLOGIES, 2019, 1 (01): : 125 - 129
  • [25] Winding turn-to-turn short-circuit diagnosis using FRA method: sensitivity of measurement configuration
    Devadiga, Anurag A.
    Harid, Noureddine
    Griffiths, Huw
    Al Sayari, Naji
    Barkat, Braham
    Jayaram, Sheshakamal
    Ikeda, Hisatoshi
    Koshizuka, Tadashi
    Taniguchi, Yasuhiko
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2019, 13 (01) : 17 - 24
  • [26] The Application of ANN in Fault Diagnosis for Generator Rotor Winding Turn-to-turn Faults
    Ma, Hongzhong
    Ding, Yuanyuan
    Ju, P.
    Zhang, Limin
    2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 2024 - +
  • [27] Frequency Response Technique to Recognize Turn-to-Turn Insulation Deterioration in Transformer Winding
    Bagheri, Mehdi
    Stojcevski, Blagojce
    Phung, B. T.
    2016 IEEE INTERNATIONAL CONFERENCE ON POWER AND RENEWABLE ENERGY (ICPRE), 2016, : 105 - 109
  • [28] Simulation of a Turn-to-Turn Short Circuit in an Induction-Motor Rotor Winding
    Lavrenov E.O.
    Vilberger M.E.
    Temlyakova Z.S.
    Morozov P.V.
    Temlyakov A.A.
    Russian Electrical Engineering, 2022, 93 (05) : 326 - 330
  • [29] Early Detection of Turn-to-Turn Faults in Power Transformer Winding: An Experimental Study
    Moradzadeh, Arash
    Pourhossein, Kazem
    2019 INTERNATIONAL AEGEAN CONFERENCE ON ELECTRICAL MACHINES AND POWER ELECTRONICS (ACEMP) & 2019 INTERNATIONAL CONFERENCE ON OPTIMIZATION OF ELECTRICAL AND ELECTRONIC EQUIPMENT (OPTIM), 2019, : 199 - 204
  • [30] Frequency Response and Vibration Analysis in Transformer Winding Turn-to-Turn Fault Recognition
    Bagheri, M.
    Phung, B. T.
    2016 INTERNATIONAL CONFERENCE ON SMART GREEN TECHNOLOGY IN ELECTRICAL AND INFORMATION SYSTEMS (ICSGTEIS), 2016, : 10 - 15