Isomorphic contact resonance force microscopy and piezoresponse force microscopy of an AlN thin film: demonstration of a new contact resonance technique

被引:2
|
作者
Robins, Lawrence H. [1 ]
Brubaker, Matt D. [2 ]
Tung, Ryan C. [3 ]
Killgore, Jason P. [1 ]
机构
[1] NIST, Appl Chem & Mat Div, Boulder, CO 80309 USA
[2] NIST, Div Appl Phys, Boulder, CO USA
[3] Univ Nevada Reno, Dept Mech Engn, Reno, NV USA
关键词
atomic force microscopy; contact resonance force microscopy; piezoresponse force microscopy; piezoelectric thin film; electromechanical properties; CALIBRATION;
D O I
10.1088/2399-1984/ab844f
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
We present a new contact resonance force microscopy (CRFM) imaging technique, isomorphic contact resonance (iso-CR), that acquires data at a constant contact resonance (CR) frequency, and hence constant tip-sample contact stiffness across the scan area. Constant CR frequency is obtained by performing force versus distance measurements to vary the applied force at each pixel (i.e. force-volume mapping mode). The CR frequency increases with increasing applied force; thus, a carefully selected target frequency will be reached for most pixels at some point in the force versus distance curve. In the iso-CR mode, the cantilever maintains an invariant vibrational shape and a constant environmental damping, thus simplifying interpretation of amplitude and quality factor contrast compared to conventional CRFM. Iso-CR imaging of a piezoelectric AlN thin film sample is demonstrated. Iso-CRFM images were obtained by mechanically driving the base of the cantilever, and iso-CR piezoresponse force microscopy (iso-CR-PFM) images were obtained by electrically biasing the tip. The PFM phase images reveal that the sample contains nanoscale Al-polar (or 'up') and N-polar (or 'down') domains, with approximate to 180 degrees phase contrast between oppositely polarized domains. The PFM amplitude and Q-factor images also show 'up' vs. 'down' domain contrast, which decreases with increasing CR frequency. The frequency-dependent amplitude and Q contrast is ascribed to a frequency-dependent electrostatic contribution to the signal. Domain contrast is not observed in the CRFM (mechanically driven) images. To summarize, the iso-CR capability to control the resonance frequency across multiple excitation schemes helps elucidate the origin of the electromechanical and nanomechanical image contrast.
引用
收藏
页码:1 / 19
页数:19
相关论文
共 50 条
  • [21] Mapping substrate/film adhesion with contact-resonance-frequency atomic force microscopy
    Hurley, D. C.
    Kopycinska-Muller, M.
    Langlois, E. D.
    Kos, A. B.
    Barbosa, N., III
    APPLIED PHYSICS LETTERS, 2006, 89 (02)
  • [22] Measuring stiffness and residual stress of thin films by contact resonance atomic force microscopy
    Ma, Chengfu
    Chen, Yuhang
    Chen, Jianfeng
    Chu, Jiaru
    APPLIED PHYSICS EXPRESS, 2016, 9 (11)
  • [23] Magnetic resonance force microscopy studies in a thin permalloy film
    Nazaretski, E.
    Thompson, J. D.
    Pelekhov, D. V.
    Mewes, T.
    Wigen, P. E.
    Kim, J.
    Zalalutdinov, M.
    Baldwin, J. W.
    Houston, B.
    Hammel, P. C.
    Movshovich, R.
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2007, 310 (02) : E941 - E943
  • [24] Identifying intrinsic ferroelectricity of thin film with piezoresponse force microscopy
    Guan, Zhao
    Jiang, Zhen-Zheng
    Tian, Bo-Bo
    Zhu, Yi-Ping
    Xiang, Ping-Hua
    Zhong, Ni
    Duan, Chun-Gang
    Chu, Jun-Hao
    AIP ADVANCES, 2017, 7 (09):
  • [25] Micromechanical contact stiffness devices and application for calibrating contact resonance atomic force microscopy
    Rosenberger, Matthew R.
    Chen, Sihan
    Prater, Craig B.
    King, William P.
    NANOTECHNOLOGY, 2017, 28 (04)
  • [26] Continuous Measurement of Atomic Force Microscope Tip Wear by Contact Resonance Force Microscopy
    Killgore, Jason P.
    Geiss, Roy H.
    Hurley, Donna C.
    SMALL, 2011, 7 (08) : 1018 - 1022
  • [27] The intrinsic piezoresponse in piezoelectric medium under contact-mode piezoresponse force microscopy
    Zhu, R. K.
    Ming, W. J.
    Liu, Y. Y.
    Pan, K.
    Lei, C. H.
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2018, 145 : 400 - 409
  • [28] Contact resonance atomic force microscopy using long elastic tips
    Zimron-Politi, Nadav
    Tung, Ryan C.
    NANOTECHNOLOGY, 2024, 35 (07)
  • [29] Quantitative subsurface contact resonance force microscopy of model polymer nanocomposites
    Killgore, Jason P.
    Kelly, Jennifer Y.
    Stafford, Christopher M.
    Fasolka, Michael J.
    Hurley, Donna C.
    NANOTECHNOLOGY, 2011, 22 (17)
  • [30] Scanning speed phenomenon in contact-resonance atomic force microscopy
    Glover, Christopher C.
    Killgore, Jason P.
    Tung, Ryan C.
    BEILSTEIN JOURNAL OF NANOTECHNOLOGY, 2018, 9 : 945 - 952