Measurement of rib vertebral angle difference - Intraobserver error and interobserver variation

被引:16
|
作者
McAlindon, RJ [1 ]
Kruse, RW [1 ]
机构
[1] ALFRED I DUPONT INST,EDITORIAL SERV,DEPT ORTHOPAED,WILMINGTON,DE 19899
关键词
interobserver error; intraobserver error; rib vertebral angle difference; scoliosis;
D O I
10.1097/00007632-199701150-00013
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. The rib vertebral angle difference was measured on 50 juvenile scoliosis radiographs. Three observers measured each radiograph independently and on three separate occasions to determine interobserver and intraobserver error. Objective. To determine the interobserver and intraobserver error in measuring the rib vertebral angle difference. Summary of Background Data. The rib vertebral angle difference is a commonly used measurement, the reliability of which has not been tested rigorously. Methods. Fifty standing radiographs of juvenile scoliosis were measured. All patients were Risser 0 at the time of measurement. All angles were measured by the method of Mehta using the same protractor and apical vertebra to avoid confounding variables. Three surgeons individually measured the 50 radiographs randomly and on three separate occasions. All markings were erased before remeasurement. Results. The intraobserver error was determined to be 4.4 degrees. The interobserver error was 3.6 degrees. The interobserver accuracy was 6.2 degrees. Conclusions. The rib vertebral angle measurement is highly reproducible and is a valid measurement.
引用
收藏
页码:198 / 199
页数:2
相关论文
共 50 条
  • [41] Intraobserver and interobserver agreement in evaluating the anterior chamber angle configuration by ultrasound biomicroscopy
    Spaeth, GL
    AzuaraBlanco, A
    Araujo, SV
    Augsburger, JJ
    JOURNAL OF GLAUCOMA, 1997, 6 (01) : 13 - 17
  • [42] Intraobserver and interobserver variance in the measurement of ultrasound-estimated bladder weight
    Naya, Y
    Kojima, M
    Honjyo, H
    Ochiai, A
    Ukimura, O
    Watanabe, H
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (05): : 771 - 773
  • [43] Intraobserver and interobserver variability of transesophageal echocardiography in aortic arch atheroma measurement
    Weber, Annemarie
    Jones, Elizabeth F.
    Zavala, Jorge A.
    Ponnuthurai, Francis A.
    Donnan, Geoffrey A.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2008, 21 (02) : 129 - 133
  • [44] Intraobserver and interobserver variation of myocardial perfusion SPECT results related to repeated reconsructions
    Kraft, M.
    Koivumaki, T.
    Hakulinen, M.
    Kokkonen, M.
    Leinonen, A.
    Laitinen, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S830 - S830
  • [45] Interobserver and intraobserver variation in endoscopic assessment of GERD using the "Los Angeles" classification
    Kusano, M
    Ino, K
    Yamada, T
    Kawamura, O
    Toki, M
    Ohwada, T
    Kikuchi, K
    Shirota, T
    Kimura, M
    Miyazaki, M
    Nakamura, K
    Igarashi, S
    Tomizawa, W
    Tamura, T
    Sekiguchi, T
    Mori, M
    GASTROINTESTINAL ENDOSCOPY, 1999, 49 (06) : 700 - 704
  • [46] ROTATOR CUFF DISORDERS - INTEROBSERVER AND INTRAOBSERVER VARIATION IN DIAGNOSIS WITH MR-IMAGING
    ROBERTSON, PL
    SCHWEITZER, ME
    MITCHELL, DG
    SCHLESINGER, F
    EPSTEIN, RE
    FRIEMAN, BG
    FENLIN, JM
    RADIOLOGY, 1995, 194 (03) : 831 - 835
  • [47] Interobserver and intraobserver variation in the assessment of the healing of tibial fractures after intramedullary fixation
    Whelan, DB
    Bhandari, M
    McKee, MD
    Guyatt, GH
    Kreder, HJ
    Stephen, D
    Schemitsch, EH
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B : 15 - 18
  • [48] REPRODUCIBILITY OF THE BANFF CLASSIFICATION OF RENAL-ALLOGRAFT PATHOLOGY - INTEROBSERVER AND INTRAOBSERVER VARIATION
    MARCUSSEN, N
    OLSEN, TS
    BENEDIKTSSON, H
    RACUSEN, L
    SOLEZ, K
    TRANSPLANTATION, 1995, 60 (10) : 1083 - 1089
  • [49] Angle Measurement in Critical Forearm Radiography in Pediatric Patients with Forearm Fractures Undergoing Conservative Treatment: Interobserver and Intraobserver Correlation Study
    Tasdemir, Zeki
    Bulut, Guven
    Colak, Ilker
    MEDICAL JOURNAL OF BAKIRKOY, 2020, 16 (01) : 85 - 89
  • [50] INTRAOBSERVER AND INTEROBSERVER VARIATION ON MEASUREMENT OF CLOSING VOLUME AND QUANTITATIVE-ANALYSIS OF ALVEOLAR PLATEAU OF SINGLE-BREATH NITROGEN WASHOUT
    RASMUSSEN, FV
    ANDERSEN, LH
    BULLETIN DE PHYSIO-PATHOLOGIE RESPIRATOIRE, 1975, 11 (01): : P27 - P32