Measurement of rib vertebral angle difference - Intraobserver error and interobserver variation

被引:16
|
作者
McAlindon, RJ [1 ]
Kruse, RW [1 ]
机构
[1] ALFRED I DUPONT INST,EDITORIAL SERV,DEPT ORTHOPAED,WILMINGTON,DE 19899
关键词
interobserver error; intraobserver error; rib vertebral angle difference; scoliosis;
D O I
10.1097/00007632-199701150-00013
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. The rib vertebral angle difference was measured on 50 juvenile scoliosis radiographs. Three observers measured each radiograph independently and on three separate occasions to determine interobserver and intraobserver error. Objective. To determine the interobserver and intraobserver error in measuring the rib vertebral angle difference. Summary of Background Data. The rib vertebral angle difference is a commonly used measurement, the reliability of which has not been tested rigorously. Methods. Fifty standing radiographs of juvenile scoliosis were measured. All patients were Risser 0 at the time of measurement. All angles were measured by the method of Mehta using the same protractor and apical vertebra to avoid confounding variables. Three surgeons individually measured the 50 radiographs randomly and on three separate occasions. All markings were erased before remeasurement. Results. The intraobserver error was determined to be 4.4 degrees. The interobserver error was 3.6 degrees. The interobserver accuracy was 6.2 degrees. Conclusions. The rib vertebral angle measurement is highly reproducible and is a valid measurement.
引用
收藏
页码:198 / 199
页数:2
相关论文
共 50 条
  • [21] Intraobserver and interobserver variation in the sonographic grading of placental maturity
    Sau, A
    Seed, P
    Langford, K
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2004, 23 (04) : 374 - 377
  • [22] INTEROBSERVER AND INTRAOBSERVER VARIATION IN THE AMNIOTIC-FLUID INDEX
    PEEDICAYIL, A
    MATHAI, M
    REGI, A
    JEYASEELAN, L
    REKHA, K
    JASPER, P
    OBSTETRICS AND GYNECOLOGY, 1994, 84 (05): : 848 - 851
  • [23] Interobserver and intraobserver variation in day 3 embryo grading
    Bendus, Allison E. Baxter
    Mayer, Jacob F.
    Shipley, Sharon K.
    Catherino, William H.
    FERTILITY AND STERILITY, 2006, 86 (06) : 1608 - 1615
  • [24] Interobserver and intraobserver reliability of the cervicomedullary angle in a normal adult population
    Wang, Shenglin
    Wang, Chao
    Passias, Peter G.
    Li, Gang
    Yan, Ming
    Zhou, Haitao
    EUROPEAN SPINE JOURNAL, 2009, 18 (09) : 1349 - 1354
  • [25] Interobserver and intraobserver reliability of the cervicomedullary angle in a normal adult population
    Shenglin Wang
    Chao Wang
    Peter G. Passias
    Gang Li
    Ming Yan
    Haitao Zhou
    European Spine Journal, 2009, 18 : 1349 - 1354
  • [26] Intraobserver and interobserver measurements of the anorectal angle and perineal descent in defecography
    Choi, JS
    Wexner, SD
    Nam, YS
    Mavrantonis, C
    Salum, MR
    Yamaguchi, T
    Weiss, EG
    Nogueras, JJ
    Yu, CF
    DISEASES OF THE COLON & RECTUM, 2000, 43 (08) : 1121 - 1126
  • [27] INTRAOBSERVER AND INTEROBSERVER AGREEMENT IN MEASUREMENT OF OPTIC DISK CHARACTERISTICS
    TIELSCH, JM
    KATZ, J
    QUIGLEY, HA
    MILLER, NR
    SOMMER, A
    OPHTHALMOLOGY, 1988, 95 (03) : 350 - 356
  • [28] MEASUREMENT OF ULTRASOUND BIOMICROSCOPY IMAGES - INTRAOBSERVER AND INTEROBSERVER RELIABILITY
    TELLO, C
    LIEBMANN, J
    POTASH, SD
    COHEN, H
    RITCH, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (09) : 3549 - 3552
  • [29] Interobserver and intraobserver variation in classification systems for fractures of the distal humerus
    Wainwright, AI
    Williams, JR
    Carr, AJ
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (05): : 636 - 642
  • [30] Interobserver and intraobserver variation in determining intrarenal parameters by Doppler sonography
    Gottlieb, RH
    Snitzer, EL
    Hartley, DF
    Fultz, PJ
    Rubens, DJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (03) : 627 - 631