Correction of detector nonlinearity in Fourier transform spectroscopy with a low-temperature blackbody

被引:14
|
作者
Fiedler, L
Newman, S
Bakan, S
机构
[1] Met Off, Exeter EX1 3PB, Devon, England
[2] European Org Exploitat Meteorol Satellites, D-64295 Darmstadt, Germany
[3] Max Planck Inst Meteorol, D-20146 Hamburg, Germany
关键词
D O I
10.1364/AO.44.005332
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The nonlinearity of a mercury cadmium telluride photoconductive detector, an integral part of a modified commercial interferometer used for airborne research, has been analyzed and evaluated against a number of correction schemes. A high-quality blackbody with accurate temperature control has been used as a stable and well-characterized radiation source. The detector nonlinearity was established as a function of scene temperature between 194 and 263 K. Second- and third-order corrections to the measured interferogram have been tested by analyzing the measured signal both within and outside the spectral response region of the detector. A combined correction scheme is proposed that best represents the real nonlinear response of the detector.
引用
收藏
页码:5332 / 5340
页数:9
相关论文
共 50 条
  • [21] Low-temperature rheo-optical Fourier transform near infrared spectroscopy of poly(dimethylsiloxane)/polycarbonate copolymers
    Kolomiets, O.
    Hoffmann, G. G.
    Siesler, H. W.
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2006, 14 (06) : 379 - 386
  • [22] A Phase Correction Model for Fourier Transform Spectroscopy
    Cheng, Huishi
    Shen, Honghai
    Meng, Lingtong
    Ben, Chenzhao
    Jia, Ping
    APPLIED SCIENCES-BASEL, 2024, 14 (05):
  • [23] A TECHNIQUE FOR PHASE CORRECTION IN FOURIER TRANSFORM SPECTROSCOPY
    Artsang, P.
    Pongchalee, P.
    Palawong, K.
    Buisset, C.
    Meemon, P.
    THIRD INTERNATIONAL CONFERENCE ON PHOTONICS SOLUTIONS (ICPS2017), 2018, 10714
  • [24] Comparison of Blackbody Sources for Low-Temperature IR Calibration
    Ljungblad, S.
    Holmsten, M.
    Josefson, L. E.
    Klason, P.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2015, 36 (12) : 3310 - 3319
  • [25] Uncertainties in blackbody corrections for low-temperature radiation thermometers
    Saunders, P.
    Manoi, A.
    METROLOGIA, 2020, 57 (02)
  • [26] Comparison of Blackbody Sources for Low-Temperature IR Calibration
    S. Ljungblad
    M. Holmsten
    L. E. Josefson
    P. Klason
    International Journal of Thermophysics, 2015, 36 : 3310 - 3319
  • [27] A low-temperature blackbody reference source to -40°C
    Chu, B
    Machin, G
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1999, 10 (01) : 1 - 6
  • [28] FOURIER-TRANSFORM INFRARED STUDIES OF RHODOPSIN AND ITS PHOTOPRODUCTS AT LOW-TEMPERATURE
    BAGLEY, K
    DOLLINGER, G
    EISENSTEIN, L
    VITTITOW, J
    ZIMANYI, L
    EBREY, TG
    NELSON, B
    BIOPHYSICAL JOURNAL, 1983, 41 (02) : A337 - A337
  • [29] THE USE OF DIFFUSE-REFLECTANCE INFRARED FOURIER-TRANSFORM SPECTROSCOPY TO MONITOR REACTIONS IN LOW-TEMPERATURE FILMS AND MATRICES
    DUNKIN, IR
    GALLIVAN, SL
    VIBRATIONAL SPECTROSCOPY, 1995, 9 (01) : 85 - 91
  • [30] PHASE CORRECTION IN MICROWAVE FOURIER-TRANSFORM SPECTROSCOPY
    HEINEKING, N
    DREIZLER, H
    ZEITSCHRIFT FUR NATURFORSCHUNG SECTION A-A JOURNAL OF PHYSICAL SCIENCES, 1989, 44 (06): : 573 - 576