Quantitative Mapping of Tumor Vascularity Using Volumetric Contrast-Enhanced Ultrasound

被引:80
|
作者
Hoyt, Kenneth [1 ,2 ,3 ]
Sorace, Anna [2 ]
Saini, Reshu [2 ]
机构
[1] Univ Alabama Birmingham, Dept Radiol, Birmingham, AL 35294 USA
[2] Univ Alabama Birmingham, Dept Biomed Engn, Birmingham, AL 35294 USA
[3] Univ Alabama Birmingham, Ctr Comprehens Canc, Birmingham, AL 35294 USA
关键词
contrast agent; microbubbles; perfusion imaging; volumetric ultrasound imaging; BLOOD-FLOW; ANGIOGENESIS; BREAST; MODEL; US; MICROCIRCULATION; THERAPY;
D O I
10.1097/RLI.0b013e318234e6bc
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The goal of this research project was to develop a volumetric strategy for real-time monitoring and characterization of tumor blood flow using microbubble contrast agents and ultrasound (US) imaging. Materials and Methods: Volumetric contrast-enhanced US (VCEUS) imaging was implemented on a SONIX RP US system (Ultrasonix Medical Corp, Richmond, BC) equipped with a broadband 4DL14-5/38 probe. Using a microbubble-sensitive harmonic imaging mode (transducer transmits at 5 MHz and receives at 10 MHz), acquisition of postscan-converted VCEUS data was achieved at a volume rate of 1 Hz. After microbubble infusion, custom data processing software was used to derive microbubble time-intensity curve-specific parameters, namely, blood volume (I PK), transit time (T1/2PK), flow rate (S PK), and tumor perfusion (AUC). Results: Using a preclinical breast cancer animal model, it is shown that millimeter-sized deviations in transducer positioning can have profound implications on US-based blood flow estimators, with errors ranging from 6.4% to 40.3% and dependent on both degree of misalignment (offset) and particular blood flow estimator. These errors indicate that VCEUS imaging should be considered in tumor analyses, because they incorporate the entire mass and not just a representative planar cross-section. After administration of an antiangiogenic therapeutic drug (bevacizumab), tumor growth was significantly retarded compared with control tumors (P > 0.03) and reflects observed changes in VCEUS-based blood flow measurements. Analysis of immunohistologic data revealed no differences in intratumoral necrosis levels (P = 0.70), but a significant difference was found when comparing microvessel density counts in control with therapy group tumors (P = 0.05). Conclusions: VCEUS imaging was shown to be a promising modality for monitoring changes in tumor blood flow. Preliminary experimental results are encouraging, and this imaging modality may prove clinically feasible for detecting and monitoring the early antitumor effects in response to cancer drug therapy.
引用
收藏
页码:167 / 174
页数:8
相关论文
共 50 条
  • [1] Volumetric Contrast-Enhanced Ultrasound for Characterizing Tumor Vascularity: Preliminary Studies in an Animal Model
    Hoyt, Kenneth
    Sorace, Anna G.
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 1292 - 1295
  • [2] Evaluation of Uterine Fibroid Vascularity Using Contrast-Enhanced Ultrasound in Comparison with Contrast-Enhanced Magnetic Resonance Imaging
    Machado, Priscilla
    Tan, Allison
    Forsberg, Flemming
    Gonsalves, Carin F.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2024, 50 (03): : 394 - 398
  • [3] Quantitative Volumetric Perfusion Mapping of the Microvasculature Using Contrast Ultrasound
    Feingold, Steven
    Gessner, Ryan
    Guracar, Ismayil M.
    Dayton, Paul A.
    INVESTIGATIVE RADIOLOGY, 2010, 45 (10) : 669 - 674
  • [4] Assessment and Monitoring Tumor Vascularity With Contrast-Enhanced Ultrasound Maximum Intensity Persistence Imaging
    Pysz, Marybeth A.
    Foygel, Kira
    Panje, Cedric M.
    Needles, Andrew
    Tian, Lu
    Willmann, Juergen K.
    INVESTIGATIVE RADIOLOGY, 2011, 46 (03) : 187 - 195
  • [5] Using Contrast-Enhanced Ultrasound for Brain Tumor Surgery
    Oliveira, Marcelo de Lima
    Picarelli, Helder
    Menezes, Marcos R.
    Teixeira, Manoel J.
    Bor-Seng-Shu, Edson
    NEUROSURGERY, 2015, 76 (01) : E104 - E105
  • [6] Quantitative perfusion analysis using contrast-enhanced ultrasound for benign and malignant choroidal tumor
    Raval, Vishal
    Karmarkar, Jayashree
    Mercado-Shekhar, Karla P.
    Shekhar, Himanshu
    Singh, Arun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [7] Contrast-enhanced ultrasonography for assessment of tumor vascularity in hepatocellular carcinoma
    Wang, Zhili
    Tang, Jie
    An, Lichun
    Wang, Wei
    Luo, Yukun
    Li, Junlai
    Xu, Jianhong
    JOURNAL OF ULTRASOUND IN MEDICINE, 2007, 26 (06) : 757 - 762
  • [8] CONTRAST-ENHANCED SONOGRAPHIC EVALUATIONS OF MURINE TUMOR VASCULARITY: A REVIEW
    Wood, A. K. W.
    Burite, R. M.
    Cary, T. W.
    Sehgal, C. M.
    VETERINARY RADIOLOGY & ULTRASOUND, 2010, 51 (02) : 190 - 190
  • [9] Volumetric Contrast-Enhanced Ultrasound Imaging of Renal Perfusion
    Mahoney, Marshall
    Sorace, Anna
    Warram, Jason
    Samuel, Sharon
    Hoyt, Kenneth
    JOURNAL OF ULTRASOUND IN MEDICINE, 2014, 33 (08) : 1427 - 1437
  • [10] In Reply: Using Contrast-Enhanced Ultrasound for Brain Tumor Surgery
    Prada, Francesco
    DiMeco, Francesco
    NEUROSURGERY, 2015, 76 (01) : E105 - E106