Quantitative Mapping of Tumor Vascularity Using Volumetric Contrast-Enhanced Ultrasound

被引:80
|
作者
Hoyt, Kenneth [1 ,2 ,3 ]
Sorace, Anna [2 ]
Saini, Reshu [2 ]
机构
[1] Univ Alabama Birmingham, Dept Radiol, Birmingham, AL 35294 USA
[2] Univ Alabama Birmingham, Dept Biomed Engn, Birmingham, AL 35294 USA
[3] Univ Alabama Birmingham, Ctr Comprehens Canc, Birmingham, AL 35294 USA
关键词
contrast agent; microbubbles; perfusion imaging; volumetric ultrasound imaging; BLOOD-FLOW; ANGIOGENESIS; BREAST; MODEL; US; MICROCIRCULATION; THERAPY;
D O I
10.1097/RLI.0b013e318234e6bc
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The goal of this research project was to develop a volumetric strategy for real-time monitoring and characterization of tumor blood flow using microbubble contrast agents and ultrasound (US) imaging. Materials and Methods: Volumetric contrast-enhanced US (VCEUS) imaging was implemented on a SONIX RP US system (Ultrasonix Medical Corp, Richmond, BC) equipped with a broadband 4DL14-5/38 probe. Using a microbubble-sensitive harmonic imaging mode (transducer transmits at 5 MHz and receives at 10 MHz), acquisition of postscan-converted VCEUS data was achieved at a volume rate of 1 Hz. After microbubble infusion, custom data processing software was used to derive microbubble time-intensity curve-specific parameters, namely, blood volume (I PK), transit time (T1/2PK), flow rate (S PK), and tumor perfusion (AUC). Results: Using a preclinical breast cancer animal model, it is shown that millimeter-sized deviations in transducer positioning can have profound implications on US-based blood flow estimators, with errors ranging from 6.4% to 40.3% and dependent on both degree of misalignment (offset) and particular blood flow estimator. These errors indicate that VCEUS imaging should be considered in tumor analyses, because they incorporate the entire mass and not just a representative planar cross-section. After administration of an antiangiogenic therapeutic drug (bevacizumab), tumor growth was significantly retarded compared with control tumors (P > 0.03) and reflects observed changes in VCEUS-based blood flow measurements. Analysis of immunohistologic data revealed no differences in intratumoral necrosis levels (P = 0.70), but a significant difference was found when comparing microvessel density counts in control with therapy group tumors (P = 0.05). Conclusions: VCEUS imaging was shown to be a promising modality for monitoring changes in tumor blood flow. Preliminary experimental results are encouraging, and this imaging modality may prove clinically feasible for detecting and monitoring the early antitumor effects in response to cancer drug therapy.
引用
收藏
页码:167 / 174
页数:8
相关论文
共 50 条
  • [41] Quantitative contrast-enhanced ultrasound imaging: a review of sources of variability
    Tang, M. -X.
    Mulvana, H.
    Gauthier, T.
    Lim, A. K. P.
    Cosgrove, D. O.
    Eckersley, R. J.
    Stride, E.
    INTERFACE FOCUS, 2011, 1 (04) : 520 - 539
  • [42] Quantitative Analysis of Microperfusion in Contrast-Induced Nephropathy Using Contrast-Enhanced Ultrasound: An Animal Study
    Seo, Nieun
    Oh, Hyewon
    Oh, Hyung Jung
    Chung, Yong Eun
    KOREAN JOURNAL OF RADIOLOGY, 2021, 22 (05) : 801 - 810
  • [43] Quantitative assessment of tumor angiogenesis using real-time motion-compensated contrast-enhanced ultrasound imaging
    Marybeth A. Pysz
    Ismayil Guracar
    Kira Foygel
    Lu Tian
    Jürgen K. Willmann
    Angiogenesis, 2012, 15 : 433 - 442
  • [44] Quantitative assessment of tumor angiogenesis using real-time motion-compensated contrast-enhanced ultrasound imaging
    Pysz, Marybeth A.
    Guracar, Ismayil
    Foygel, Kira
    Tian, Lu
    Willmann, Juergen K.
    ANGIOGENESIS, 2012, 15 (03) : 433 - 442
  • [45] Quantitative Analysis of Perfusion Characteristics Using Contrast-Enhanced Ultrasound in Patients with Choroidal Metastasis
    Li, Dongjun
    Wang, Ziyang
    Chen, Wei
    Zhao, Qi
    Li, Yifeng
    Cui, Rui
    Shen, Lin
    Liu, Qian
    Cao, Kai
    Liu, Yueming
    Wei, Wenbin
    Yang, Wenli
    OPHTHALMIC RESEARCH, 2022, 65 (01) : 86 - 93
  • [46] Contrast-Enhanced Ultrasound Fundamentals: The Pharmacodynamics and Pharmacokinetics of Contrast. Basics of Contrast-Enhanced Ultrasound Imaging
    Fontanilla Echeveste, M. T.
    Ripolles Gonzalez, T.
    Aguirre Pascual, E.
    RADIOLOGIA, 2024, 66 : S36 - S50
  • [47] Clinical Value of Contrast-Enhanced Ultrasound in Atypical Wilms Tumor
    Damjana Ključevšek
    Mojca Glušič
    Orjana Velikonja
    Indian Journal of Pediatrics, 2021, 88 : 517 - 518
  • [48] Contrast-Enhanced Ultrasound Tumor Therapy With Abdominal Imaging Transducer
    Morrison, Ryan G.
    Karmacharya, Mrigendra B.
    Sehgal, Chandra M.
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2022, 16 (04):
  • [49] Fractal dimension of tumor microvasculature by dynamic contrast-enhanced ultrasound
    Mischi, Massimo
    Heneweer, Carola
    von Broich-Oppert, Julian
    Saidov, Tamerlan
    Wijkstra, Hessel
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [50] Contrast-enhanced ultrasound improves the differential diagnosis of liver tumor
    Strobel, D
    Baltzer, M
    Bernatik, T
    Hansler, J
    Martus, P
    Hahn, EG
    JOURNAL OF HEPATOLOGY, 2004, 40 : 83 - 84