Performance of a solar liquid desiccant air conditioner - An experimental and theoretical approach

被引:57
|
作者
Alizadeh, Shahab [1 ]
机构
[1] Queensland Univ Technol, Fac Built Environm & Engn, Brisbane, Qld 4001, Australia
关键词
liquid desiccant; indirect evaporative cooling; dehumidification; polymer plate heat exchanger; solar regeneration;
D O I
10.1016/j.solener.2007.10.009
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this paper the results of testing a solar liquid desiccant air conditioner (LDAC) in the tropical climate of Queensland, Australia have been presented. The system uses polymer plate heat exchanger (PPHE) for dehumidification/indirect evaporative cooling, and a cooling pad as the direct evaporative cooler for the dry air leaving the PPHE. Lithium chloride, which is an effective desiccant in air dehumidification, was used in the experiments and a scavenger air regenerator concentrates the dilute solution from the dehumidifier using hot water from flat plate solar collectors. The data obtained from performance monitoring of the solar LDAC operating on a commercial site in Brisbane was compared with a previously developed model for the PPHE. The comparison reveals that good agreement exists between the experiments and model predictions. The inaccuracies are well within the measuring errors of the temperature, humidity and the air and solution flow rates. The above tests further indicate a satisfactory performance of the unit by independently controlling the air temperature and humidity inside the conditioned space. In order to prevent carryover of the solution particles into the environment, eliminators are used at outlet of the absorber unit and the regenerator. An alternative method in preventing the carryover is the use of indirect cooling, in which the supply air does not contact the solution. The method can be used to produce potable water from the atmospheric air in remote areas. The liquid desiccant system can be used in the HVAC industry, either as a packaged roof-top air conditioner, or as an air handler unit for commercial applications. The system could also be used for space heating in winter due to the property of desiccants to provide heat when wetted. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:563 / 572
页数:10
相关论文
共 50 条
  • [31] Experimental Investigation of Air Conditioner using the Desiccant Cooling System in Equatorial Climates
    Abdullah, Kamaruddin
    Uyun, Aep Saepul
    Nur, Syukri Muhammad
    Bamahry, Alie
    Imanda, Rino
    Mahlia, Teuku Meurah Indra
    3RD INTERNATIONAL CONFERENCE ON ELECTRICAL SYSTEMS, TECHNOLOGY AND INFORMATION (ICESTI 2017), 2018, 164
  • [32] Experimental investigation on compressed air drying performance using pressurized liquid desiccant
    Yin, Yonggao
    Zheng, Baojun
    Shao, Bin
    Zhang, Xiaosong
    DRYING TECHNOLOGY, 2016, 34 (03) : 372 - 382
  • [33] Experimental performance of polymeric air-solution contactors for liquid desiccant systems
    Prieto, Juan
    Ortiga, Jordi
    Coronas, Alberto
    APPLIED THERMAL ENGINEERING, 2017, 121 : 576 - 584
  • [34] Theoretical performance study of a liquid desiccant regenerator supported with scavenging air heat exchanger
    Kabeel, A. E.
    Bassuoni, M. M.
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2013, 5 (02)
  • [35] Theoretical investigation on energy storage characteristics of a solar liquid desiccant air conditioning system in Egypt
    Kabeel, A. E.
    Khalil, A.
    Elsayed, S. S.
    Alatyar, A. M.
    ENERGY, 2018, 158 : 164 - 180
  • [36] Design and performance improvement of a solar desalination system by using solar air heater: Experimental and theoretical approach
    Siddiqui, Farooq R.
    Elminshawy, Nabil A. S.
    Addas, Mohammad F.
    DESALINATION, 2016, 399 : 78 - 87
  • [37] Theoretical and experimental examination of air conditioner heat exchangers
    Gemici, Zafer
    Egrican, Nilufer
    Koca, Aliihsan
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2010, 37 (06) : 681 - 686
  • [38] Experimental and theoretical study of automotive air conditioner condensers
    Peng, XB
    Yan, QS
    HEAT TRANSFER SCIENCE AND TECHNOLOGY 1996, 1996, : 603 - 608
  • [39] Experimental performance of indirect air-liquid membrane contactors for liquid desiccant cooling systems
    Das, Rajat Subhra
    Jain, Sanjeev
    ENERGY, 2013, 57 : 319 - 325
  • [40] Modeling and performance analysis of solar air pretreatment collector/regenerator using liquid desiccant
    Peng, Donggen
    Zhang, Xiaosong
    RENEWABLE ENERGY, 2009, 34 (03) : 699 - 705