Experimental investigation on compressed air drying performance using pressurized liquid desiccant

被引:6
|
作者
Yin, Yonggao [1 ,2 ,3 ]
Zheng, Baojun [1 ]
Shao, Bin [1 ]
Zhang, Xiaosong [1 ,2 ,3 ]
机构
[1] Southeast Univ, Sch Energy & Environm, Nanjing 210096, Jiangsu, Peoples R China
[2] Southeast Univ, Minist Educ, Key Lab Energy Thermal Convers & Control, Nanjing 210096, Jiangsu, Peoples R China
[3] Southeast Univ, Jiangsu Prov Key Lab Solar Energy Sci & Technol, Nanjing 210096, Jiangsu, Peoples R China
关键词
Compressed air; drying performance; energy analysis; experiment; liquid desiccant; pressurized dehumidifier; RESEARCH-AND-DEVELOPMENT; DEHUMIDIFIER; TEMPERATURE; SYSTEMS; BED;
D O I
10.1080/07373937.2015.1057838
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
As a new compressed air-drying method, the compressed air dehumidification using a pressurized liquid desiccant was proposed in our previous study. The pressurized dehumidifier is a complex and core component of the drying system. The mass transfer performance between the compressed air and LiCl aqueous solution is experimentally studied in a counter-flow pressurized dehumidifier filled with structured packing. The humidity ratio of outlet compressed air, vapor removal of processed compressed air, moisture removal rate, and dehumidification efficiency were selected as the performance indices. The results show that the minimum humidity ratio of processed compressed air could reach 0.23g/kg under 0.71MPa. Compressed air-drying performance could be remarkably enhanced through increasing the air pressure and liquid desiccant inlet concentration while the influence of liquid desiccant temperature is negative. Furthermore, in order to ensure high compressed air-drying performance, reduce the power consumption of the air compressor and liquid desiccant pump, and the possibility of carryover, the optimum ratio of liquid to compressed air flow rate is recommended to be around 1.5 under pressure around 0.50MPa. Meanwhile, the energy consumption for per-gram moisture removal of a liquid-desiccant-based compressed air-drying system can reach 1.42kJ/g lower than cooling dehumidification under 0.3MPa, which is 16.0% lower than a compressed air-cooling dehumidification system.
引用
收藏
页码:372 / 382
页数:11
相关论文
共 50 条
  • [1] A proposed compressed air drying method using pressurized liquid desiccant and experimental verification
    Yin, Yonggao
    Zheng, Baojun
    Yang, Can
    Zhang, Xiaosong
    APPLIED ENERGY, 2015, 141 : 80 - 89
  • [2] A novel compressed air drying method based on pressurized liquid desiccant dehumidifier and experimental verification
    Zheng, Baojun
    Yin, Yonggao
    Zhang, Xiaosong
    Huagong Xuebao/CIESC Journal, 2014, 65 : 52 - 57
  • [3] Experimental and simulated study on a novel compressed air drying system using a liquid desiccant cycle
    Zhan, Changfeng
    Yin, Yonggao
    Jin, Xing
    Zhang, Xiaosong
    ENERGY, 2018, 162 : 60 - 71
  • [4] Experimental study on drying characteristics of compressed air drying system using liquid desiccant driven by air compressor waste heat
    Wang Z.
    Yin Y.
    Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2019, 49 (05): : 851 - 857
  • [5] Experimental Investigation of Thermal Performance Parameters of Drying Air Unit with a Different Flowrate of Liquid Desiccant Solution
    Hassen, Abdulsalam D. M.
    Al-Azawy, Mohammed G.
    Mahdy, Hussain H.
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2022, 40 (03) : 815 - 820
  • [6] Experimental Investigation on a Novel Air Dehumidifier Using Liquid Desiccant
    Qiu, G. Q.
    Riffat, S. B.
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2010, 7 (02) : 174 - 180
  • [7] Investigation on drying performance and alternative analysis of different liquid desiccants in compressed air drying system
    Zhan, Changfeng
    Yin, Yonggao
    Guo, Xiaoshuang
    Jin, Xing
    Zhang, Xiaosong
    ENERGY, 2018, 165 : 1 - 9
  • [8] Performance investigation and exergy analysis of air-handling processes using liquid desiccant and a desiccant wheel
    Zhang, Tao
    Liu, Xiaohua
    Liu, Jun
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2017, 23 (01) : 105 - 115
  • [9] DRYING COMPRESSED-AIR - SINGLE-TOWER DESICCANT DRYING SYSTEMS
    SRIRAMAMURTY, DV
    PLANT ENGINEERING, 1983, 37 (15) : 51 - 54
  • [10] Performance of a solar liquid desiccant air conditioner - An experimental and theoretical approach
    Alizadeh, Shahab
    SOLAR ENERGY, 2008, 82 (06) : 563 - 572