Experimental investigation on compressed air drying performance using pressurized liquid desiccant

被引:6
|
作者
Yin, Yonggao [1 ,2 ,3 ]
Zheng, Baojun [1 ]
Shao, Bin [1 ]
Zhang, Xiaosong [1 ,2 ,3 ]
机构
[1] Southeast Univ, Sch Energy & Environm, Nanjing 210096, Jiangsu, Peoples R China
[2] Southeast Univ, Minist Educ, Key Lab Energy Thermal Convers & Control, Nanjing 210096, Jiangsu, Peoples R China
[3] Southeast Univ, Jiangsu Prov Key Lab Solar Energy Sci & Technol, Nanjing 210096, Jiangsu, Peoples R China
关键词
Compressed air; drying performance; energy analysis; experiment; liquid desiccant; pressurized dehumidifier; RESEARCH-AND-DEVELOPMENT; DEHUMIDIFIER; TEMPERATURE; SYSTEMS; BED;
D O I
10.1080/07373937.2015.1057838
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
As a new compressed air-drying method, the compressed air dehumidification using a pressurized liquid desiccant was proposed in our previous study. The pressurized dehumidifier is a complex and core component of the drying system. The mass transfer performance between the compressed air and LiCl aqueous solution is experimentally studied in a counter-flow pressurized dehumidifier filled with structured packing. The humidity ratio of outlet compressed air, vapor removal of processed compressed air, moisture removal rate, and dehumidification efficiency were selected as the performance indices. The results show that the minimum humidity ratio of processed compressed air could reach 0.23g/kg under 0.71MPa. Compressed air-drying performance could be remarkably enhanced through increasing the air pressure and liquid desiccant inlet concentration while the influence of liquid desiccant temperature is negative. Furthermore, in order to ensure high compressed air-drying performance, reduce the power consumption of the air compressor and liquid desiccant pump, and the possibility of carryover, the optimum ratio of liquid to compressed air flow rate is recommended to be around 1.5 under pressure around 0.50MPa. Meanwhile, the energy consumption for per-gram moisture removal of a liquid-desiccant-based compressed air-drying system can reach 1.42kJ/g lower than cooling dehumidification under 0.3MPa, which is 16.0% lower than a compressed air-cooling dehumidification system.
引用
收藏
页码:372 / 382
页数:11
相关论文
共 50 条
  • [31] Experimental Investigation of Air Conditioner using the Desiccant Cooling System in Equatorial Climates
    Abdullah, Kamaruddin
    Uyun, Aep Saepul
    Nur, Syukri Muhammad
    Bamahry, Alie
    Imanda, Rino
    Mahlia, Teuku Meurah Indra
    3RD INTERNATIONAL CONFERENCE ON ELECTRICAL SYSTEMS, TECHNOLOGY AND INFORMATION (ICESTI 2017), 2018, 164
  • [32] Experimental Investigation on the Performance of a Compressed-Air Driven Piston Engine
    Huang, Chih-Yung
    Hu, Cheng-Kang
    Yu, Chih-Jie
    Sung, Cheng-Kuo
    ENERGIES, 2013, 6 (03) : 1731 - 1745
  • [33] Dehumidification performance improvement by using liquid desiccant blends - An experimental study
    Kumar, Shiva
    Parida, Subhransu S.
    Kumar, Nitesh
    INDOOR AND BUILT ENVIRONMENT, 2023, 32 (05) : 1020 - 1032
  • [34] Experimental investigations on performance of liquid desiccant-vapor compression hybrid air conditioner
    Mohan, B. Shaji
    Tiwari, Shaligram
    Maiya, M. P.
    APPLIED THERMAL ENGINEERING, 2015, 77 : 153 - 162
  • [35] Experimental investigation of electrical conductivity of liquid desiccant solution
    Cheng, Qing
    Zhang, Xiaosong
    ELECTRICAL POWER & ENERGY SYSTEMS, PTS 1 AND 2, 2012, 516-517 : 1910 - 1916
  • [36] Experimental investigation and performance analysis of a spray-type ionic liquid desiccant dehumidifier
    Liang, Jyun-De
    Kao, Chia-Lin
    Chen, Chih-Hao
    Ho, Hong-Yi
    Huang, Chih-Hsueh
    Chen, Sih-Li
    APPLIED THERMAL ENGINEERING, 2024, 254
  • [37] Experimental investigation on the mass transfer performance of a novel packing used for liquid desiccant systems
    Chen, Tingting
    Dai, Zhichao
    Yin, Yonggao
    Zhang, Xiaosong
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2017, 23 (01) : 46 - 59
  • [38] Experimental analysis on chemical dehumidification of air by liquid desiccant and desiccant regeneration in a packed tower
    Longo, GA
    Gasparella, A
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2004, 126 (01): : 587 - 591
  • [39] Experimental investigation on pressurized liquid in confining nanoenvironment
    Surani, Falgun B.
    Han, Aijie
    Qiao, Yu
    APPLIED PHYSICS LETTERS, 2006, 89 (09)
  • [40] Performance investigation and exergy analysis of enthalpy recovery device using liquid desiccant
    Zhang, Tao
    Liu, Xiaohua
    Jiang, Yi
    APPLIED THERMAL ENGINEERING, 2016, 106 : 76 - 86