The usefulness of low radiation dose subtraction coronary computed tomography angiography for patients with calcification using 320-row area detector CT

被引:9
|
作者
Takamura, Kazuhisa [1 ]
Fujimoto, Shinichiro [1 ]
Kawaguchi, Yuko [1 ]
Kato, Etsuro [1 ]
Aoshima, Chihiro [1 ]
Hiki, Makoto [1 ]
Kumamaru, Kanako K. [2 ]
Daida, Hiroyuki [1 ]
机构
[1] Juntendo Univ, Grad Sch Med, Dept Cardiovasc Med, Tokyo, Japan
[2] Juntendo Univ, Grad Sch Med, Dept Radiol, Tokyo, Japan
基金
日本学术振兴会;
关键词
Coronary artery calcification; Subtraction computed tomography; angiography; Radiation dosing; Diagnostic ability; IMAGE QUALITY; ITERATIVE RECONSTRUCTION; DIAGNOSTIC PERFORMANCE; ARTERY STENOSIS; FEASIBILITY; ACCURACY; PROTOCOL;
D O I
10.1016/j.jjcc.2018.05.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Although subtraction coronary computed tomography angiography (S-CCTA) has recently been developed to improve the diagnostic ability in patients with severe calcification, increase in radiation exposure remains a concern. The usefulness of S-CCTA using a low-radiation dose protocol was investigated. Methods: S-CCTA in 320-row area detector CT was performed on 84 consecutive patients with suspected obstructive coronary artery disease with Agatston score >= 100. Reconstruction and radiation dose were changed according to the slow filling time (SF) (137.5 ms < SF <= 262.5 ms. Half reconstruction without reduction of the current, 262.5 ms < SF <= 275 ms: automatic patient motion correction with 50% reduction, SF >= 275 ms: full reconstruction with 70% reduction) at a tube voltage of 100 kV. The percentage of patients with non-diagnostic stenosis of calcified coronary artery lesions was calculated in conventional (C-) CCTA, and S-CCTA was calculated based on 84 patients (446 segments) bases. In 27 patients (137 segments) examined by invasive coronary angiography (ICA), the diagnostic ability was investigated regarding the ICA findings as reference standard. Results: The percentage of non-diagnostic patients and segments on C-CCTA vs. S-CCTA was 40.5% vs. 9.5% and 16.4% vs. 2.9%, respectively. The Agatston score was 589.3 +/- 655.3, and the total effective radiation dose (non-contrast scan and C-CCTA) was 2.7 +/- 1.1 mSv. In the 27 patients, 137 segments area under the curve of S-CCTA (0.939, 95% CI: 0.895-0.983) for the ICA findings as reference standard was significantly higher than that of C-CCTA (0.785, 95% Cl: 0.713-0.858) (p < 0.0001). Conclusion: The diagnostic ability of S-CCTA performed following the low-radiation dose protocol for patients with calcification was superior to that of C-CCTA alone. (C) 2018 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:58 / 64
页数:7
相关论文
共 50 条
  • [41] Diagnostic Accuracy of Noninvasive Coronary Angiography With 320-Detector Row Computed Tomography
    Nasis, Arthur
    Leung, Michael C.
    Antonis, Paul R.
    Cameron, James D.
    Lehman, Sam J.
    Hope, Sarah A.
    Crossett, Marcus P.
    Troupis, John M.
    Meredith, Ian T.
    Seneviratne, Sujith K.
    AMERICAN JOURNAL OF CARDIOLOGY, 2010, 106 (10): : 1429 - 1435
  • [42] Whole-Heart 320-Row Computed Tomography: Reduction of Radiation Dose via Prior Coronary Calcium Scanning
    Zimmermann, E.
    Dewey, M.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2011, 183 (01): : 54 - 59
  • [43] Dynamic Enhancement Pattern is Different Between Unstable and Stable Coronary Plaque: Analysis With 320-Row Area Detector Computed Tomography
    Kameyama, Tomoki
    Ihori, Hiroyuki
    Ohara, Kazumasa
    Nonomura, Makoto
    Inoue, Hiroshi
    CIRCULATION, 2017, 136
  • [44] Annular Flow in the Upper Esophageal Sphincter Demonstrated with Dynamic 320-row Area Detector Computed Tomography
    Yoko Inamoto
    Eiichi Saitoh
    Jeffrey B. Palmer
    Dysphagia, 2021, 36 : 1088 - 1094
  • [45] Diagnostic performance of coronary angiography utilizing intraprocedural 320-row computed tomography with minimal contrast medium
    Misato Chimura
    Tomohito Ohtani
    Kensuke Yokoi
    Tatsuya Shiraki
    Themistoklis Katsimichas
    Takashi Kitao
    Masaki Awata
    Isamu Mizote
    Shungo Hikoso
    Satoru Sumitsuji
    Yasushi Sakata
    Heart and Vessels, 2020, 35 : 1341 - 1348
  • [46] Diagnostic performance of coronary angiography utilizing intraprocedural 320-row computed tomography with minimal contrast medium
    Chimura, Misato
    Ohtani, Tomohito
    Yokoi, Kensuke
    Shiraki, Tatsuya
    Katsimichas, Themistoklis
    Kitao, Takashi
    Awata, Masaki
    Mizote, Isamu
    Hikoso, Shungo
    Sumitsuji, Satoru
    Sakata, Yasushi
    HEART AND VESSELS, 2020, 35 (10) : 1341 - 1348
  • [47] The plaque characteristics of chronic kidney disease patients with diabetes mellitus: utility of 320-row area detector computed tomography
    Kawai, H.
    Sarai, M.
    Harigaya, H.
    Motoyama, S.
    Hara, T.
    Naruse, H.
    Ozaki, Y.
    EUROPEAN HEART JOURNAL, 2010, 31 : 524 - 524
  • [48] Subtraction Coronary CT Angiography for the Evaluation of Severely Calcified Lesions Using a 320-Detector Row Scanner
    Yoshioka K.
    Tanaka R.
    Current Cardiovascular Imaging Reports, 2011, 4 (6) : 437 - 446
  • [49] Feasibility of 320-row area detector CT coronary angiography using 40 mL of contrast material: assessment of image quality and diagnostic accuracy
    Rihyeon Kim
    Eun-Ah Park
    Whal Lee
    Jin Wook Chung
    European Radiology, 2016, 26 : 3802 - 3810
  • [50] Feasibility of 320-row area detector CT coronary angiography using 40 mL of contrast material: assessment of image quality and diagnostic accuracy
    Kim, Rihyeon
    Park, Eun-Ah
    Lee, Whal
    Chung, Jin Wook