The usefulness of low radiation dose subtraction coronary computed tomography angiography for patients with calcification using 320-row area detector CT

被引:9
|
作者
Takamura, Kazuhisa [1 ]
Fujimoto, Shinichiro [1 ]
Kawaguchi, Yuko [1 ]
Kato, Etsuro [1 ]
Aoshima, Chihiro [1 ]
Hiki, Makoto [1 ]
Kumamaru, Kanako K. [2 ]
Daida, Hiroyuki [1 ]
机构
[1] Juntendo Univ, Grad Sch Med, Dept Cardiovasc Med, Tokyo, Japan
[2] Juntendo Univ, Grad Sch Med, Dept Radiol, Tokyo, Japan
基金
日本学术振兴会;
关键词
Coronary artery calcification; Subtraction computed tomography; angiography; Radiation dosing; Diagnostic ability; IMAGE QUALITY; ITERATIVE RECONSTRUCTION; DIAGNOSTIC PERFORMANCE; ARTERY STENOSIS; FEASIBILITY; ACCURACY; PROTOCOL;
D O I
10.1016/j.jjcc.2018.05.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Although subtraction coronary computed tomography angiography (S-CCTA) has recently been developed to improve the diagnostic ability in patients with severe calcification, increase in radiation exposure remains a concern. The usefulness of S-CCTA using a low-radiation dose protocol was investigated. Methods: S-CCTA in 320-row area detector CT was performed on 84 consecutive patients with suspected obstructive coronary artery disease with Agatston score >= 100. Reconstruction and radiation dose were changed according to the slow filling time (SF) (137.5 ms < SF <= 262.5 ms. Half reconstruction without reduction of the current, 262.5 ms < SF <= 275 ms: automatic patient motion correction with 50% reduction, SF >= 275 ms: full reconstruction with 70% reduction) at a tube voltage of 100 kV. The percentage of patients with non-diagnostic stenosis of calcified coronary artery lesions was calculated in conventional (C-) CCTA, and S-CCTA was calculated based on 84 patients (446 segments) bases. In 27 patients (137 segments) examined by invasive coronary angiography (ICA), the diagnostic ability was investigated regarding the ICA findings as reference standard. Results: The percentage of non-diagnostic patients and segments on C-CCTA vs. S-CCTA was 40.5% vs. 9.5% and 16.4% vs. 2.9%, respectively. The Agatston score was 589.3 +/- 655.3, and the total effective radiation dose (non-contrast scan and C-CCTA) was 2.7 +/- 1.1 mSv. In the 27 patients, 137 segments area under the curve of S-CCTA (0.939, 95% CI: 0.895-0.983) for the ICA findings as reference standard was significantly higher than that of C-CCTA (0.785, 95% Cl: 0.713-0.858) (p < 0.0001). Conclusion: The diagnostic ability of S-CCTA performed following the low-radiation dose protocol for patients with calcification was superior to that of C-CCTA alone. (C) 2018 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:58 / 64
页数:7
相关论文
共 50 条
  • [31] Radiation dose exposure of patients undergoing 320-row cardiac CT for assessing coronary angiography and global left ventricular function
    Chen, Chien-Ming
    Liu, Yuan-Chang
    Chen, Chun-Chi
    Wen, Ming-Shien
    Hung, Chien-Fu
    Wan, Yung-Liang
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 : 1 - 5
  • [32] Evaluation of CT coronary artery angiography with 320-row detector CT in a high-risk population
    Gang, S.
    Min, L.
    Li, L.
    Guo-Ying, L.
    Lin, X.
    Qun, J.
    Hua, Z.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1013): : 562 - 570
  • [33] Early stage of chronic kidney disease develops coronary atherosclerosis but does not increase vulnerable plaques: usefulness of 320-row area detector computed tomography
    Kawai, H.
    Sarai, M.
    Harigaya, H.
    Motoyama, S.
    Hara, T.
    Naruse, H.
    Ozaki, Y.
    EUROPEAN HEART JOURNAL, 2010, 31 : 434 - 434
  • [34] Feasibility of coronary calcium and stent image subtraction using 320-detector row CT angiography
    Fuchs, Andreas
    Kuhl, J. Tobias
    Chen, Marcus Y.
    Helquist, Steffen
    Razeto, Marco
    Arakita, Kazumasa
    Steveson, Chloe
    Arai, Andrew E.
    Kofoed, Klaus F.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2015, 9 (05) : 393 - 398
  • [35] Submillisievert imaging protocol using full reconstruction and advanced patient motion correction in 320-row area detector coronary CT angiography
    Yuko Kawaguchi
    Shinichiro Fujimoto
    Kazuhisa Takamura
    Etsuro Kato
    Shoko Suda
    Rie Matsumori
    Makoto Hiki
    Kanako K. Kumamaru
    Hiroyuki Daida
    The International Journal of Cardiovascular Imaging, 2018, 34 : 465 - 474
  • [36] Measurement of Pharyngo-laryngeal Volume During Swallowing Using 320-Row Area Detector Computed Tomography
    Iida, Takatoshi
    Kagaya, Hitoshi
    Inamoto, Yoko
    Shibata, Seiko
    Saitoh, Eiichi
    Kanamori, Daisuke
    Hashimoto, Shuji
    Katada, Kazuhiro
    Tohara, Haruka
    Ueda, Koichiro
    DYSPHAGIA, 2017, 32 (06) : 749 - 758
  • [37] Measurement of Pharyngo-laryngeal Volume During Swallowing Using 320-Row Area Detector Computed Tomography
    Takatoshi Iida
    Hitoshi Kagaya
    Yoko Inamoto
    Seiko Shibata
    Eiichi Saitoh
    Daisuke Kanamori
    Shuji Hashimoto
    Kazuhiro Katada
    Haruka Tohara
    Koichiro Ueda
    Dysphagia, 2017, 32 : 749 - 758
  • [38] Submillisievert imaging protocol using full reconstruction and advanced patient motion correction in 320-row area detector coronary CT angiography
    Kawaguchi, Yuko
    Fujimoto, Shinichiro
    Takamura, Kazuhisa
    Kato, Etsuro
    Suda, Shoko
    Matsumori, Rie
    Hiki, Makoto
    Kumamaru, Kanako K.
    Daida, Hiroyuki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2018, 34 (03): : 465 - 474
  • [39] Minimizing the acquisition phase in coronary CT angiography using the second generation 320-row CT
    Tomizawa, Nobuo
    Kanno, Shigeaki
    Maeda, Eriko
    Akahane, Masaaki
    Torigoe, Rumiko
    Ohtomo, Kuni
    JAPANESE JOURNAL OF RADIOLOGY, 2014, 32 (07) : 391 - 396
  • [40] Minimizing the acquisition phase in coronary CT angiography using the second generation 320-row CT
    Nobuo Tomizawa
    Shigeaki Kanno
    Eriko Maeda
    Masaaki Akahane
    Rumiko Torigoe
    Kuni Ohtomo
    Japanese Journal of Radiology, 2014, 32 : 391 - 396