The usefulness of low radiation dose subtraction coronary computed tomography angiography for patients with calcification using 320-row area detector CT

被引:9
|
作者
Takamura, Kazuhisa [1 ]
Fujimoto, Shinichiro [1 ]
Kawaguchi, Yuko [1 ]
Kato, Etsuro [1 ]
Aoshima, Chihiro [1 ]
Hiki, Makoto [1 ]
Kumamaru, Kanako K. [2 ]
Daida, Hiroyuki [1 ]
机构
[1] Juntendo Univ, Grad Sch Med, Dept Cardiovasc Med, Tokyo, Japan
[2] Juntendo Univ, Grad Sch Med, Dept Radiol, Tokyo, Japan
基金
日本学术振兴会;
关键词
Coronary artery calcification; Subtraction computed tomography; angiography; Radiation dosing; Diagnostic ability; IMAGE QUALITY; ITERATIVE RECONSTRUCTION; DIAGNOSTIC PERFORMANCE; ARTERY STENOSIS; FEASIBILITY; ACCURACY; PROTOCOL;
D O I
10.1016/j.jjcc.2018.05.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Although subtraction coronary computed tomography angiography (S-CCTA) has recently been developed to improve the diagnostic ability in patients with severe calcification, increase in radiation exposure remains a concern. The usefulness of S-CCTA using a low-radiation dose protocol was investigated. Methods: S-CCTA in 320-row area detector CT was performed on 84 consecutive patients with suspected obstructive coronary artery disease with Agatston score >= 100. Reconstruction and radiation dose were changed according to the slow filling time (SF) (137.5 ms < SF <= 262.5 ms. Half reconstruction without reduction of the current, 262.5 ms < SF <= 275 ms: automatic patient motion correction with 50% reduction, SF >= 275 ms: full reconstruction with 70% reduction) at a tube voltage of 100 kV. The percentage of patients with non-diagnostic stenosis of calcified coronary artery lesions was calculated in conventional (C-) CCTA, and S-CCTA was calculated based on 84 patients (446 segments) bases. In 27 patients (137 segments) examined by invasive coronary angiography (ICA), the diagnostic ability was investigated regarding the ICA findings as reference standard. Results: The percentage of non-diagnostic patients and segments on C-CCTA vs. S-CCTA was 40.5% vs. 9.5% and 16.4% vs. 2.9%, respectively. The Agatston score was 589.3 +/- 655.3, and the total effective radiation dose (non-contrast scan and C-CCTA) was 2.7 +/- 1.1 mSv. In the 27 patients, 137 segments area under the curve of S-CCTA (0.939, 95% CI: 0.895-0.983) for the ICA findings as reference standard was significantly higher than that of C-CCTA (0.785, 95% Cl: 0.713-0.858) (p < 0.0001). Conclusion: The diagnostic ability of S-CCTA performed following the low-radiation dose protocol for patients with calcification was superior to that of C-CCTA alone. (C) 2018 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:58 / 64
页数:7
相关论文
共 50 条
  • [1] The usefulness of subtraction coronary computed tomography angiography for in-stent restenosis assessment of patients with CoCr stent using 320-row area detector CT
    Li, Jian
    Guo, Man-Tao
    Yang, Xiao
    Gao, Fang
    Li, Na
    Huang, Ming-Gang
    MEDICINE, 2021, 100 (51) : E28345
  • [2] Image Quality of Coronary Computed Tomography Angiography with 320-Row Area Detector Computed Tomography in Children with Congenital Heart Disease
    Tada, Akihiro
    Sato, Shuhei
    Kanie, Yuichiro
    Tanaka, Takashi
    Inai, Ryota
    Akagi, Noriaki
    Morimitsu, Yusuke
    Kanazawa, Susumu
    PEDIATRIC CARDIOLOGY, 2016, 37 (03) : 497 - 503
  • [3] Image quality of coronary computed tomography angiography with 320-Row area detector computed tomography in children with congenital heart disease
    Qin, Jie
    Cai, Songwang
    Peng, Lingrong
    Tang, Wenjie
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (16) : C142 - C142
  • [4] Image Quality of Coronary Computed Tomography Angiography with 320-Row Area Detector Computed Tomography in Children with Congenital Heart Disease
    Akihiro Tada
    Shuhei Sato
    Yuichiro Kanie
    Takashi Tanaka
    Ryota Inai
    Noriaki Akagi
    Yusuke Morimitsu
    Susumu Kanazawa
    Pediatric Cardiology, 2016, 37 : 497 - 503
  • [5] Usefulness of 320-Row Area Detector Computed Tomography for the Diagnosis of Cystic Falx Meningioma
    Tabuchi, Sadaharu
    Nakajima, Sadao
    CASE REPORTS IN ONCOLOGY, 2013, 6 (02): : 362 - 366
  • [6] REDUCTION OF RADIATION DOSE OF 320-ROW CORONARY COMPUTED TOMOGRAPHY ANGIOGRAPHY THROUGH PRIOR CORONARY CALCIUM SCANNING
    Dewey, Marc
    Zimmermann, Elke
    Wollenberg, Ulrike
    Rief, Matthias
    Greupner, Johannes
    Hamm, Bernd
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [7] Imaging of the temporal bone in children using low-dose 320-row area detector computed tomography
    Tada, Akihiro
    Sato, Shuhei
    Masaoka, Yoshihisa
    Kanazawa, Susumu
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2017, 61 (04) : 489 - 493
  • [8] Radiation dose for 320-row dose-modulated dynamic coronary CT angiography
    Izoe, Yukako
    Nagao, Michinobu
    Tokai, Mei
    Hashimoto, Hiroyuki
    Tanaka, Isao
    Chida, Koichi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (09): : 307 - 312
  • [9] Subtracted Computed Tomography Angiography in the Evaluation of Coronary Arteries With Severe Calcification or Stents Using a 320-Row Computed Tomography Scanner
    Chen, Chun-Chi
    Wu, Patricia Wanping
    Tsay, Pei-Kwei
    Wang, Chun-Chieh
    Toh, Cheng-Hong
    Wan, Yung-Liang
    JOURNAL OF THORACIC IMAGING, 2020, 35 (05) : 317 - 325
  • [10] Evaluation of Pharyngoesophageal Segment Using 320-Row Area Detector Computed Tomography
    Wattanapan, Pattra
    Kagaya, Hitoshi
    Inamoto, Yoko
    Saitoh, Eiichi
    Shibata, Seiko
    Iida, Takatoshi
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2018, 127 (12): : 888 - 894