Re-treatment rates after treatment with the Pipeline Embolization Device alone versus Pipeline and coil embolization of cerebral aneurysms: a single-center experience

被引:44
|
作者
Park, Min S. [1 ]
Nanaszko, Michael [2 ]
Sanborn, Matthew R. [2 ]
Moon, Karam [2 ]
Albuquerque, Felipe C. [2 ]
McDougall, Cameron G. [2 ]
机构
[1] Univ Utah Hlth Care, Dept Neurosurg, Salt Lake City, UT USA
[2] St Josephs Hosp, Barrow Neurol Inst, Dept Neurosurg, Phoenix, AZ USA
关键词
aneurysms; coil embolization; flow diversion; Pipeline Embolization Device; re-treatment; vascular disorders; INTRACRANIAL ANEURYSMS; FLOW-DIVERSION; RECONSTRUCTION; COMPLICATIONS;
D O I
10.3171/2015.7.JNS15582
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE The optimal strategy for use of the Pipeline Embolization Device (PED, ev3 Neurovascular) has not been clearly defined. The authors examined re-treatment rates after treatment with PED alone versus PED and adjunctive coil embolization (PED/coil). METHODS The authors retrospectively examined cerebral aneurysms treated with the PED from May 2011 to March 2014. Overall, 133 patients (25 men, 108 women; mean age 60.4 years, range 23-85 years) were treated for 140 aneurysms (mean size 11.8 +/- 8.3 mm) requiring 224 PEDs (mean 1.7 PEDs per patient). Sixty-eight patients (13 men, 55 women) were treated with PED alone for 73 aneurysms (mean size 10.6 +/- 9.2 mm) and 65 patients (12 men, 53 women) were treated with PED/coil for 67 aneurysms (mean size 12.8 +/- 7.4 mm). RESULTS Eight aneurysms in 8 patients were re-treated in the PED-alone cohort versus only 1 aneurysm in 1 patient in the PED/coil cohort for re-treatment rates of 11.8% (8/68) and 1.5% (1/65), respectively (p = 0.03). Two patients in the PED-alone cohort were re-treated due to PED contraction, while the other 6 were re-treated for persistent filling of the aneurysms. The PED/coil patient experienced continued filling of a vertebrobasilar artery aneurysm. No aneurysms in either group ruptured after treatment. CONCLUSIONS Adjunctive coil embolization during flow diversion with the PED resulted in a significantly lower re treatment rate compared with PED alone, suggesting an added benefit with adjunctive coil embolization. This result may provide the basis for future evaluation with randomized, controlled trials.
引用
收藏
页码:137 / 144
页数:8
相关论文
共 50 条
  • [41] Pipeline embolization of complex, wide-necked middle cerebral artery bifurcation aneurysms: A single-center experience
    Wang, Jingjing
    Deng, Xin
    Li, Dong
    Yang, Zhen
    Guo, Xin-Bin
    INTERVENTIONAL NEURORADIOLOGY, 2024, 30 (02) : 227 - 233
  • [42] Endovascular Treatment of Complex Distal Posterior Cerebral Artery Aneurysms with the Pipeline Embolization Device
    Mazaris, Paul
    Mehta, Tapan
    Hussain, Mohammed
    Inoa, Violiza
    Singer, Justin
    Spiegel, Gary
    Kureshi, Inam
    Ollenschleger, Martin
    WORLD NEUROSURGERY, 2017, 107 : 1043.e1 - 1043.e5
  • [43] Safety and Efficacy of Coils in Conjunction With the Pipeline Flex Embolization Device for the Treatment of Cerebral Aneurysms
    Zhang, Qianqian
    Shao, Qiuji
    Chang, Kaitao
    Zhang, Hongyun
    He, Yingkun
    Andrade-Barazarte, Hugo
    Sheng, Zhiyuan
    Mo, Xiao
    Zemmar, Ajmal
    Li, Li
    Li, Tianxiao
    FRONTIERS IN NEUROLOGY, 2021, 12
  • [44] Intraprocedural Rupture of Unruptured Cerebral Aneurysms During Coil Embolization: A Single-Center Experience
    Cho, Su Hee
    Denewer, Mohammed
    Park, Wonhyoung
    Ahn, Jae Sung
    Kwun, Byung Duk
    Lee, Deok Hee
    Park, Jung Cheol
    WORLD NEUROSURGERY, 2017, 105 : 177 - 183
  • [45] Endovascular Reconstruction of Intracranial Aneurysms with the Pipeline Embolization Device in Pediatric Patients: A Single-Center Series
    Shirani, Peyman
    Mirbagheri, Saeedeh
    Shapiro, Maksim
    Raz, Eytan
    Mowla, Ashkan
    Semsarieh, Bita
    Riina, Howard A.
    Nelson, Peter K.
    INTERVENTIONAL NEUROLOGY, 2020, 8 (2-6) : 101 - 108
  • [46] Early Postmarket Results After Treatment of Intracranial Aneurysms With the Pipeline Embolization Device: A US Multicenter Experience
    Kan, Peter
    Siddiqui, AdnanH.
    Veznedaroglu, Erol
    Liebman, Kenneth M.
    Binning, Mandy J.
    Dumont, Travis M.
    Ogilvy, Christopher S.
    Gaughen, John R., Jr.
    Mocco, J.
    Velat, Gregory J.
    Ringer, Andrew J.
    Welch, Babu G.
    Horowitz, Michael B.
    Snyder, Kenneth V.
    Hopkins, L. Nelson
    Levy, Elad I.
    NEUROSURGERY, 2012, 71 (06) : 1080 - 1087
  • [47] Treatment of Distal Anterior Circulation Aneurysms With the Pipeline Embolization Device: A US Multicenter Experience
    Lin, Ning
    Lanzino, Giuseppe
    Lopes, Demetrius K.
    Arthur, Adam S.
    Ogilvy, Christopher S.
    Ecker, Robert D.
    Dumont, Travis M.
    Turner, Raymond D.
    Gooch, M. Reid
    Boulos, Alan S.
    Kan, Peter
    Snyder, Kenneth V.
    Levy, Elad I.
    Siddiqui, Adnan H.
    NEUROSURGERY, 2016, 79 (01) : 14 - 22
  • [48] Utilization of Pipeline embolization device for treatment of ruptured intracranial aneurysms: US multicenter experience
    Lin, Ning
    Brouillard, Adam M.
    Keigher, Kiffon M.
    Lopes, Demetrius K.
    Binning, Mandy J.
    Liebman, Kenneth M.
    Veznedaroglu, Erol
    Magarik, Jordan A.
    Mocco, J.
    Duckworth, Edward A.
    Arthur, Adam S.
    Ringer, Andrew J.
    Snyder, Kenneth V.
    Levy, Elad I.
    Siddiqui, Adnan H.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2015, 7 (11) : 808 - 815
  • [49] Use of Pipeline Embolization Device for Posterior Circulation Aneurysms: Single-Center Experiences with Comparison with Anterior Circulation Aneurysms
    Liang, Fei
    Zhang, Yupeng
    Guo, Feng
    Zhang, Yuxiang
    Yan, Peng
    Liang, Shikai
    Jiang, Yuhua
    Jiang, Peng
    Jiang, Chuhan
    WORLD NEUROSURGERY, 2018, 112 : E683 - E690
  • [50] Outcome study of the pipeline embolization device for treatment of intracranial aneurysms at a single UK institution
    Yang, Shih-Hung
    Hampton, Timothy
    Kandasamy, Naga
    Hart, Jonathan
    Ashmore, Jonathan
    Walsh, Daniel C.
    Tolias, Christos M.
    Booth, Thomas C.
    BRITISH JOURNAL OF NEUROSURGERY, 2017, 31 (06) : 661 - 667