Effect of Implant Abutment Modification on the Extrusion of Excess Cement at the Crown-Abutment Margin for Cement-Retained Implant Restorations

被引:1
|
作者
Wadhwani, Chandur [1 ]
Pineyro, Alfonso [1 ]
Hess, Timothy [1 ]
Zhang, Hai [1 ]
Chung, Kwok-Hung [1 ]
机构
[1] Univ Washington, Dept Restorat Dent, Seattle, WA 98195 USA
关键词
cementation; cement retention; customized abutment; implant restorations; seating discrepancy; temporary cement; OSSEOINTEGRATED IMPLANTS;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To compare the effect of implant abutment modification on the amount of cement extruded at the crown-abutment margin and to evaluate the vertical discrepancy after cementation. Materials and Methods: Access openings of titanium abutments were modified with an opening (open) and placement of two vent holes 3 mm from the occlusal edge and 180 degrees apart (internal vent). Access openings were filled with resin material (closed) and used as controls. Each abutment was secured to an implant analog. Eugenol-free zinc oxide cement (TempBond NE) was selected to cement the cast crowns (n = 9) onto test abutments. The amount of cement extruded out of the margin was calculated, and vertical seating discrepancies were determined with a linear transducer device before and after cementation. Differences among groups were analyzed statistically. Results: The mean amount of extruded cement ranged from 36% to 90% of the total cement placed within the crowns. The order, from least to greatest amount of excess cement extrusion at the margins, was internal vent, open, and closed; significant differences were observed between test groups. The net vertical discrepancies of tested specimens ranged from -7 mu m to + 6 mu m (mean, 0 mu m). No statistically significant differences in vertical discrepancy were found between the groups. Conclusions: Venting the hollow abutment resulted in the least amount of cement extrusion when compared to closing off the screw access channel or leaving it open. Within the limitations of this study, it may be concluded that the use of two, 0.75-mm radius vent holes placed 3 mm apical to the occlusal area of the abutment and 180 degrees apart will limit the amount of cement extruded into the gingival sulcus of implant-retained crowns. Int J Oral Maxillofac Implants 2011;26:1241-1246
引用
收藏
页码:1241 / 1246
页数:6
相关论文
共 50 条
  • [41] Influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with a lingual slot
    Choi, Kyu-Hyung
    Son, KeunBaDa
    Lee, Du-Hyeong
    Lee, Kyu-Bok
    JOURNAL OF ADVANCED PROSTHODONTICS, 2018, 10 (05): : 381 - 387
  • [42] A Modified Plastic Shell Technique for Cement-Retained Implant Restorations
    Oezcelik, Tuncer Burak
    Yilmaz, Burak
    JOURNAL OF ORAL IMPLANTOLOGY, 2010, 36 (04) : 291 - 294
  • [43] RADIOGRAPHIC DETECTION AND CHARACTERISTIC PATTERNS OF RESIDUAL EXCESS CEMENT ASSOCIATED WITH CEMENT-RETAINED IMPLANT RESTORATIONS: A CLINICAL REPORT
    Wadhwani, Chandur
    Rapoport, Darrin
    La Rosa, Silvia
    Hess, Timothy
    Kretschmar, Stefanie
    JOURNAL OF PROSTHETIC DENTISTRY, 2012, 107 (03): : 151 - 157
  • [44] The modification of interim cylinders for the fabrication of cement-retained implant-supported provisional restorations
    Hirayama, H
    Kang, KH
    Oishi, Y
    JOURNAL OF PROSTHETIC DENTISTRY, 2003, 90 (04): : 406 - 409
  • [45] The Effect of Different Surface Treatments on Cement-Retained Implant-Supported Restorations
    Kurt, Murat
    Kulunk, Tolga
    Ural, Cagri
    Kulunk, Safak
    Danisman, Sengul
    Savas, Soner
    JOURNAL OF ORAL IMPLANTOLOGY, 2013, 39 (01) : 44 - 51
  • [46] Using a guide template with a handpiece sleeve to locate the abutment screw position of a cement-retained implant restoration
    Kang, Hye-Won
    Lee, Du-Hyeong
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (03): : 339 - 342
  • [47] Cement-retained versus screw-retained implant restorations: A critical review
    Michalakis, KX
    Hirayama, H
    Garefis, PD
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2003, 18 (05) : 719 - 728
  • [48] Bacterial penetration in the internal part of cement-retained versus screw-retained implant-abutment connections.
    Di Labio, L
    Piattelli, A
    Assenza, B
    Leghissa, GC
    Scarano, A
    Paolantonio, M
    Piccolomini, R
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 213 - 213
  • [49] Fluids and microbial penetration in the internal part of cement-retained versus screw-retained implant-abutment connections
    Piattelli, A
    Scarano, A
    Paolantonio, M
    Assenza, B
    Leghissa, GC
    Di Bonaventura, G
    Catamo, G
    Piccolomini, R
    JOURNAL OF PERIODONTOLOGY, 2001, 72 (09) : 1146 - 1150
  • [50] Effect of Metal Extension of Crown in the Screw Access Channel of a Posterior Implant Abutment on the Retention of Cement Retained Prosthesis
    Biyani, Rashmi
    Ali, Mohsin
    Belles, Donald
    Powers, John M.
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (05) : 537 - 542