Outcomes of patients subjected to aortic valve replacement surgery using mechanical or biological prostheses

被引:10
|
作者
de Almeida, Adriana Silveira [1 ,2 ]
Picon, Paulo Dornelles [1 ]
Belmonte Wender, Orlando Carlos [3 ,4 ,5 ]
机构
[1] Univ Fed Rio Grande do Sul, Dept Med Interna, Fac Med, Porto Alegre, RS, Brazil
[2] Hosp Nossa Senhora Conceicao, Grp Hosp Conceicao, Porto Alegre, RS, Brazil
[3] Univ Munique, Alemanha, Brazil
[4] Univ Fed Rio Grande do Sul, Dept Cirurgia, Fac Med, Porto Alegre, RS, Brazil
[5] Hosp Clin Porto Alegre, Serv Cirurgia Cardiovasc, Porto Alegre, RS, Brazil
来源
关键词
Bioprosthesis; Heart Valve Prosthesis Implantation; Aortic Valve; Heart Valve Prosthesis; HEART-VALVE; BIOPROSTHETIC VALVE; HOSPITAL MORTALITY; RISK; GUIDELINES; IMPACT; DETERMINANTS; REOPERATION; MORBIDITY; CHOICE;
D O I
10.5935/1678-9741.20110006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: This paper evaluates outcomes in patients subjected to surgery for replacement of the aortic valve using biological or mechanical substitutes, where selection of the type of prosthesis is relevant. Methods: Three hundred and one patients, randomly selected, who had been subjected to aortic valve replacement surgery between 1990 and 2005, with a maximum follow-up period of 20 years. Results: Survival at 5, 10 and 15 years after surgery using mechanical substitute was 83.9%, 75.4% and 60.2% and, for biological substitute, was 89.3%, 70.4% and 58.4%, respectively (P=0.939). Factors associated with death were: age, obesity, pulmonary disease, arrhythmia, bleeding and aortic valve failure. Probability free of reoperation for these patients at 5, 10 and 15 years after surgery using mechanical substitute was 97.9%, 95.8% and 95.8% and, for those using bioprostheses, was 94.6%, 91.0% and 83.3%, respectively (P=0.057). Factors associated with reoperation were: renal failure, prosthesis endocarditis and age. Probability free of bleeding events at 5, 10 and 15 years after surgery using mechanical substitute was 94.5%, 91.7% and 91.7% and, for bioprostheses, was 98.6%, 97.8% and 97.8%, respectively (P=0.047). Factors associated with bleeding events were: renal failure and mechanical prostheses. Conclusions: The authors have concluded that: 1) mortality was statistically similar in the groups; 2) patient characteristics at baseline were a major determinant of late mortality after surgery; 3) there was a tendency toward reoperation in the bioprostheses group; 4) patients using mechanical prosthesis had more bleeding events as time passed; 5) data presented in this paper is in accordance with current literature.
引用
收藏
页码:326 / 337
页数:12
相关论文
共 50 条
  • [41] Results of valve replacement with mechanical and biological prostheses in chronic renal dialysis patients - Invited commentary
    Blakeman, BP
    ANNALS OF THORACIC SURGERY, 1997, 64 (01): : 132 - 133
  • [42] Outcomes of minimally invasive aortic valve replacement surgery
    Young, Christopher P.
    Sinha, Shubhra
    Vohra, Hunaid A.
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 53 : 19 - 23
  • [43] Short-term outcomes of aortic valve neocuspidization using autologous fixed pericardium versus aortic valve replacement using mechanical prosthesis in patients with aortic valve disease
    El Barbary, Moustafa Gamal-Eldin
    Seddik, Amr Ahmed Mohamed
    Hussein, Mohamed Attia
    Omar, Ahmed Helmy
    EGYPTIAN JOURNAL OF SURGERY, 2023, 42 (03): : 774 - 780
  • [44] Aortic valve replacement with sutureless and rapid deployment aortic valve prostheses
    Paolo Berretta
    Marco Di Eusanio
    Journal of Geriatric Cardiology, 2016, 13 (06) : 504 - 510
  • [45] Outcomes of Bioprosthetic and Mechanical Aortic Valve Replacement in Patients With Congenital Heart Disease
    Hobbs, Reilly D.
    Schultz, Megan
    Wagner, Catherine
    Ohye, Richard G.
    Bove, Edward
    Si, Ming-Sing
    CIRCULATION, 2020, 142
  • [46] Aortic valve replacement with sutureless and rapid deployment aortic valve prostheses
    Berretta, Paolo
    Di Eusanio, Marco
    JOURNAL OF GERIATRIC CARDIOLOGY, 2016, 13 (06) : 504 - 510
  • [47] Early and Late Outcomes of Aortic Valve Replacement Using Bioprosthetic Versus Mechanical Valve in Elderly Patients: A Propensity Analysis
    Okamoto, Yuki
    Yamamoto, Kazuo
    Yoshii, Shinpei
    JOURNAL OF CARDIAC SURGERY, 2016, 31 (04) : 195 - 202
  • [48] Clinical Outcomes of Repeat Aortic Valve Replacement for Subaortic Pannus in Mechanical Aortic Valve
    Park, Pyo Won
    Park, Byungjoon
    Jeong, Dong Seop
    Sung, Kiick
    Kim, Wook Sung
    Lee, Young Tak
    Park, Seung Woo
    CIRCULATION JOURNAL, 2018, 82 (10) : 2535 - 2541
  • [49] Outcomes of mitral valve surgery during concomitant aortic valve replacement
    Coyan, Garrett N.
    Aranda-Michel, Edgar
    Sultan, Ibrahim
    Gleason, Thomas G.
    Navid, Forozan
    Chu, Danny
    Sharbaugh, Michael S.
    Kilic, Arman
    JOURNAL OF CARDIAC SURGERY, 2018, 33 (11) : 706 - 715
  • [50] Quality of life in aortic valve replacement:: pulmonary autografts versus mechanical prostheses
    Nötzold, A
    Hüppe, M
    Schmidtke, C
    Blömer, P
    Uhlig, T
    Sievers, HH
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (07) : 1963 - 1966