Outcomes of patients subjected to aortic valve replacement surgery using mechanical or biological prostheses

被引:10
|
作者
de Almeida, Adriana Silveira [1 ,2 ]
Picon, Paulo Dornelles [1 ]
Belmonte Wender, Orlando Carlos [3 ,4 ,5 ]
机构
[1] Univ Fed Rio Grande do Sul, Dept Med Interna, Fac Med, Porto Alegre, RS, Brazil
[2] Hosp Nossa Senhora Conceicao, Grp Hosp Conceicao, Porto Alegre, RS, Brazil
[3] Univ Munique, Alemanha, Brazil
[4] Univ Fed Rio Grande do Sul, Dept Cirurgia, Fac Med, Porto Alegre, RS, Brazil
[5] Hosp Clin Porto Alegre, Serv Cirurgia Cardiovasc, Porto Alegre, RS, Brazil
来源
关键词
Bioprosthesis; Heart Valve Prosthesis Implantation; Aortic Valve; Heart Valve Prosthesis; HEART-VALVE; BIOPROSTHETIC VALVE; HOSPITAL MORTALITY; RISK; GUIDELINES; IMPACT; DETERMINANTS; REOPERATION; MORBIDITY; CHOICE;
D O I
10.5935/1678-9741.20110006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: This paper evaluates outcomes in patients subjected to surgery for replacement of the aortic valve using biological or mechanical substitutes, where selection of the type of prosthesis is relevant. Methods: Three hundred and one patients, randomly selected, who had been subjected to aortic valve replacement surgery between 1990 and 2005, with a maximum follow-up period of 20 years. Results: Survival at 5, 10 and 15 years after surgery using mechanical substitute was 83.9%, 75.4% and 60.2% and, for biological substitute, was 89.3%, 70.4% and 58.4%, respectively (P=0.939). Factors associated with death were: age, obesity, pulmonary disease, arrhythmia, bleeding and aortic valve failure. Probability free of reoperation for these patients at 5, 10 and 15 years after surgery using mechanical substitute was 97.9%, 95.8% and 95.8% and, for those using bioprostheses, was 94.6%, 91.0% and 83.3%, respectively (P=0.057). Factors associated with reoperation were: renal failure, prosthesis endocarditis and age. Probability free of bleeding events at 5, 10 and 15 years after surgery using mechanical substitute was 94.5%, 91.7% and 91.7% and, for bioprostheses, was 98.6%, 97.8% and 97.8%, respectively (P=0.047). Factors associated with bleeding events were: renal failure and mechanical prostheses. Conclusions: The authors have concluded that: 1) mortality was statistically similar in the groups; 2) patient characteristics at baseline were a major determinant of late mortality after surgery; 3) there was a tendency toward reoperation in the bioprostheses group; 4) patients using mechanical prosthesis had more bleeding events as time passed; 5) data presented in this paper is in accordance with current literature.
引用
收藏
页码:326 / 337
页数:12
相关论文
共 50 条
  • [21] Mechanical or Biologic Prostheses for Aortic-Valve and Mitral-Valve Replacement
    Goldstone, Andrew B.
    Chiu, Peter
    Baiocchi, Michael
    Lingala, Bharathi
    Patrick, William L.
    Fischbein, Michael P.
    Woo, Y. Joseph
    NEW ENGLAND JOURNAL OF MEDICINE, 2017, 377 (19): : 1847 - 1857
  • [22] Late clinical outcomes after mechanical aortic valve replacement for aortic stenosis: old versus new prostheses
    Lee, Heemoon
    Sung, Kiick
    Kim, Wook Sung
    Jeong, Doug Seop
    Ahn, Jooug Hyun
    Carriere, Keumhee Chough
    Park, Pyo Won
    JOURNAL OF THORACIC DISEASE, 2018, 10 (06) : 3361 - +
  • [23] Mechanical Versus Biologic Prostheses for Surgical Aortic Valve Replacement in Patients 50 to 70
    Kyto, Ville
    Sipila, Jussi
    Ahtela, Elina
    Rautava, Paivi
    Gunn, Jarmo
    ANNALS OF THORACIC SURGERY, 2020, 110 (01): : 102 - 110
  • [24] Tricuspid valve replacement: Results comparing mechanical and biological prostheses
    Del Campo, C
    Sherman, JR
    ANNALS OF THORACIC SURGERY, 2000, 69 (04): : 1295 - 1295
  • [25] Early Outcomes of Aortic Valve Replacement with Sutureless and Rapid Deployment Prostheses in Dialysis Patients
    Uehara, Hiroo
    Ozawa, Naomi
    Uchiyama, Masateru
    Iwakura, Tomohiro
    Imazuru, Tomohiro
    Shimokawa, Tomoki
    HEART SURGERY FORUM, 2025, 28 (02): : E205 - E211
  • [26] Effect of prosthesis-patient mismatch on survival after aortic valve replacement using mechanical prostheses in patients with aortic stenosis
    Tsutsumi K.
    Nagumo M.
    Nishikawa K.
    Takahashi R.
    General Thoracic and Cardiovascular Surgery, 2008, 56 (12) : 577 - 583
  • [27] Coronary microvascular and diastolic dysfunctions after aortic valve replacement: comparison between mechanical and biological prostheses
    America, R.
    Miele, M. M.
    Giordano, G. M.
    Franzese, F. I.
    EUROPEAN HEART JOURNAL, 2016, 37 : 479 - 479
  • [28] BIOPROSTHETIC VERSUS MECHANICAL PROSTHESES FOR AORTIC-VALVE REPLACEMENT IN THE ELDERLY
    DAVIS, EA
    GREENE, PS
    CAMERON, DE
    GOTT, VL
    LASCHINGER, JC
    STUART, RS
    SUSSMAN, MS
    WATKINS, T
    BAUMGATTNER, WA
    CIRCULATION, 1995, 92 (08) : 2460 - 2460
  • [29] Comparison of human tissues and mechanical prostheses for aortic valve replacement in children
    Lupinetti, FM
    Warner, J
    Jones, TK
    Herndon, SP
    CIRCULATION, 1997, 96 (01) : 321 - 325
  • [30] Outcome after aortic valve replacement: Comparison of homografts with mechanical prostheses
    Kilian, Eckehard
    Oberhoffer, Martin
    Kaczmarek, Ingo
    Bauerfeind, Daniel
    Kreuzer, Eckart
    Reichart, Bruno
    JOURNAL OF HEART VALVE DISEASE, 2007, 16 (04): : 404 - 409