In-vial liquid-liquid extraction with subsequent large-volume on-column injection into GC-MS for the determination of anilines in tap, surface, and wastewater

被引:0
|
作者
Vreuls, RJJ [1 ]
Romijn, E [1 ]
Brinkman, UAT [1 ]
机构
[1] Vrije Univ Amsterdam, Dept Analyt Chem, NL-1081 HV Amsterdam, Netherlands
关键词
in-vial liquid-liquid extraction; large-volume injection; gas chromatography; on-column injector; environmental analysis; anilines;
D O I
10.1002/(SICI)1520-667X(1998)10:7<581::AID-MCS4>3.0.CO;2-C
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study miniaturized liquid-liquid extraction carried out in an autosampler vial was used to determine a series of anilines in tap, surface, and industrial wastewater. The analytes were extracted from the aqueous phase into n-hexane and 100 mu l Of the extract, i.e., 10-20%, was injected into the gas chromatography (GC) system using an on-column injector in combination with a deactivated uncoated fused silica capillary (retention gap) and an early solvent vapor exit. A mass spectrometer was used for detection and identification. The parameters for large-volume injection, i.e., the evaporation rate, speed of injection, and injection temperature, were optimized using accurate measurement of the actual flow rate of the carrier gas into the GC system. This measurement was used as input for a solvent vapor-exit controller, which was equipped with a microprocessor for determination of the endpoint of the evaporation process. The optimum conditions for an injection volume of 100 mu L of n-hexane are reported. Extraction with a water-to-n-hexane-ratio (1:1, v/v) gave quantitative recoveries except for aniline (46%). The addition of sodium chloride improved the extraction yield for aniline about 10%. Linear calibration curves were obtained in the 0.01-1-mu g/L concentration range, relative standard deviations were less than 10%, and detection limits typically were 4-20 ng/L for GC-mass spectrometry in the multiple-ion-detection mode. The total procedure allowed the analysis of unfiltered water samples; that is, no sample treatment was necessary. (C) 1998 John Wiley & Sons, Inc.
引用
收藏
页码:581 / 588
页数:8
相关论文
共 50 条
  • [31] Determination of polycyclic aromatic hydrocarbons in surface water using simplified liquid-liquid micro-extraction and pseudo-MRM GC/MS/MS
    Yan, Jeffrey
    Kim, Marcus
    Haberl, Maxine
    Kwok, Honoria
    Brunswick, Pamela
    MacInnis, Ceara
    van Aggelen, Graham
    Shang, Dayue
    ANALYTICAL METHODS, 2018, 10 (04) : 405 - 416
  • [32] Determination of pesticides in vegetables using large-volume injection column liquid chromatography-electrospray tandem mass spectrometry
    Hogenboom, AC
    Hofman, MP
    Kok, SJ
    Niessen, WMA
    Brinkman, UAT
    JOURNAL OF CHROMATOGRAPHY A, 2000, 892 (1-2) : 379 - 390
  • [33] Simultaneous determination of iprodione, procymidone, and chlorflurenol in lake water and wastewater matrices by GC-MS after multivariate optimization of binary dispersive liquid-liquid microextraction
    Nizamettin Özdoğan
    Fatih Kapukıran
    Gülşen Mutluoğlu
    Dotse Selali Chormey
    Sezgin Bakırdere
    Environmental Monitoring and Assessment, 2018, 190
  • [34] Simultaneous determination of iprodione, procymidone, and chlorflurenol in lake water and wastewater matrices by GC-MS after multivariate optimization of binary dispersive liquid-liquid microextraction
    Ozdogan, Nizamettin
    Kapukiran, Fatih
    Mutluoglu, Gulsen
    Chormey, Dotse Selali
    Bakirdere, Sezgin
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2018, 190 (10)
  • [35] Dispersive Liquid-Liquid Microextraction Based Preconcentration of Selected Pesticides and Escitalopram Oxalate, Haloperidol, and Olanzapine from Wastewater Samples Prior to Determination by GC-MS
    Bozyigit, Gamze Dalgic
    Ayyildiz, Merve Firat
    Chormey, Dotse Selali
    Engin, Guleda Onkal
    Bakirdere, Sezgin
    JOURNAL OF AOAC INTERNATIONAL, 2021, 104 (01) : 91 - 97
  • [36] Solid-phase extraction followed by deep eutectic solvent based dispersive liquid-liquid microextraction and GC-MS detection of the estrogenic compounds in wastewater samples
    Davoodi, Reza
    Nodehi, Ramin Nabizadeh
    Rastkari, Noushin
    Zinatizadeh, Ali Akbar
    Mahvi, Amir Hossein
    Fattahi, Nazir
    NEW JOURNAL OF CHEMISTRY, 2020, 44 (23) : 9844 - 9851
  • [37] Dispersive solid-phase extraction combined with dispersive liquid-liquid microextraction for the determination of polybrominated diphenyl ethers in plastic bottled beverage by GC-MS
    Han, Yi
    Jia, Xiaoyu
    Liu, Xinli
    Duan, Taicheng
    Chen, Hangting
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (09) : 1047 - 1054
  • [38] Determination of Low-ppm Levels of 1,4-Butane Sultone in Sulfobutyl Ether β-Cyclodextrin Using Liquid-Liquid Extraction and GC-MS
    Wang, Meng
    Wen, Hongmei
    Yu, Sheng
    Yan, Zhengyu
    CHROMATOGRAPHIA, 2012, 75 (15-16) : 937 - 941
  • [39] Sensitive determination of amide herbicides in environmental water samples by a combination of solid-phase extraction and dispersive liquid-liquid microextraction prior to GC-MS
    Zhao, Ru-Song
    Diao, Chun-Peng
    Chen, Qing-Feng
    Wang, Xia
    JOURNAL OF SEPARATION SCIENCE, 2009, 32 (07) : 1069 - 1074
  • [40] Direct determination of bromacil and diuron residues in environmental water samples by coupled-column liquid chromatography and large-volume injection
    Sancho, JV
    Hidalgo, C
    Hernandez, F
    JOURNAL OF CHROMATOGRAPHY A, 1997, 761 (1-2) : 322 - 326