In-vial liquid-liquid extraction with subsequent large-volume on-column injection into GC-MS for the determination of anilines in tap, surface, and wastewater

被引:0
|
作者
Vreuls, RJJ [1 ]
Romijn, E [1 ]
Brinkman, UAT [1 ]
机构
[1] Vrije Univ Amsterdam, Dept Analyt Chem, NL-1081 HV Amsterdam, Netherlands
关键词
in-vial liquid-liquid extraction; large-volume injection; gas chromatography; on-column injector; environmental analysis; anilines;
D O I
10.1002/(SICI)1520-667X(1998)10:7<581::AID-MCS4>3.0.CO;2-C
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study miniaturized liquid-liquid extraction carried out in an autosampler vial was used to determine a series of anilines in tap, surface, and industrial wastewater. The analytes were extracted from the aqueous phase into n-hexane and 100 mu l Of the extract, i.e., 10-20%, was injected into the gas chromatography (GC) system using an on-column injector in combination with a deactivated uncoated fused silica capillary (retention gap) and an early solvent vapor exit. A mass spectrometer was used for detection and identification. The parameters for large-volume injection, i.e., the evaporation rate, speed of injection, and injection temperature, were optimized using accurate measurement of the actual flow rate of the carrier gas into the GC system. This measurement was used as input for a solvent vapor-exit controller, which was equipped with a microprocessor for determination of the endpoint of the evaporation process. The optimum conditions for an injection volume of 100 mu L of n-hexane are reported. Extraction with a water-to-n-hexane-ratio (1:1, v/v) gave quantitative recoveries except for aniline (46%). The addition of sodium chloride improved the extraction yield for aniline about 10%. Linear calibration curves were obtained in the 0.01-1-mu g/L concentration range, relative standard deviations were less than 10%, and detection limits typically were 4-20 ng/L for GC-mass spectrometry in the multiple-ion-detection mode. The total procedure allowed the analysis of unfiltered water samples; that is, no sample treatment was necessary. (C) 1998 John Wiley & Sons, Inc.
引用
收藏
页码:581 / 588
页数:8
相关论文
共 50 条
  • [21] Full Scan GC-MS Quantitation of Pesticides in Spring Water at the 10 ppt Level Using Large Volume On-Column Injection
    Termonia, Arnaud
    Termonia, Marc
    1997, Wiley-VCH Verlag (20):
  • [22] Full scan GC-MS quantitation of pesticides in spring water at the 10 ppt level using large volume on-column injection
    Termonia, A
    Termonia, M
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1997, 20 (08): : 447 - 450
  • [23] Liquid-liquid extraction combined with online cleanup for the simultaneous determination of PAHs by GC-MS/MS and their hydroxylated metabolites by LC-MS/MS in human fingernails
    Zeng, Zihuan
    Gao, Yuan
    Cui, Juntao
    Lin, Meiqing
    Tang, Jian
    Wang, Fei
    Yang, Yan
    Yu, Yingxin
    Ma, Shengtao
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2022, 1188
  • [24] Determination of low ppm levels of dimethyl sulfate in an aqueous soluble API intermediate using liquid-liquid extraction and GC-MS
    Zheng, Jie
    Pritts, Wayne A.
    Zhang, Shuhong
    Wittenberger, Steve
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 50 (05) : 1054 - 1059
  • [25] Splitless large-volume GC-MS injection for the analysis of organophosphorus and organochlorine pesticides in vegetables using a miniaturised ethyl acetate extraction
    Agüera, A
    Piedra, L
    Hernando, MD
    Fernández-Alba, AR
    Contreras, M
    ANALYST, 2000, 125 (08) : 1397 - 1402
  • [26] Preconcentration and GC-MS determination of caffeine in tea and coffee using homogeneous liquid-liquid microextraction based on solvents volume ratio alteration
    Amini, Tooraj
    Hashemi, Payman
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1092 : 252 - 257
  • [27] Vortex-assisted extraction in tandem with dispersive liquid-liquid microextraction followed by GC-MS for determination of Achillea wilhelmsii essential oil
    Sereshti, Hassan
    Ghiasi, Abdollah
    Naderloo, Mandi
    Taghizadeh, Massoud
    Astaneh, Shakiba Darvish Alipoar
    ANALYTICAL METHODS, 2014, 6 (17) : 6695 - 6701
  • [28] Dispersive liquid-liquid microextraction for the determination of phenols by acetonitrile stacking coupled with sweeping-micellar electrokinetic chromatography with large-volume injection
    He, Hui
    Liu, Shuhui
    Meng, Zhaofu
    Hu, Shibing
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1361 : 291 - 298
  • [29] Pesticide Determination in Fresh Coconut Water (Cocos nucifera Linn.) by GC-MS Using Microwave-Assisted Liquid-Liquid Extraction
    Nakamura, Thamilin C.
    do Rego, Enoc L.
    de Souza, Jurandir R.
    Diniz, Paulo H. G. D.
    da Silva, Jose D. S.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2023, 34 (11) : 1707 - 1716
  • [30] Salting-out assisted liquid-liquid extraction method combined with GC-MS for the determination of topiramate in aqueous solutions: development and application of the methodology
    Ferreira De Almeida, Janiele Mayara
    Fernandes Silva, Elania Maria
    Verissimo, Lourena Mafra
    Fernandes, Nedja Suely
    SEPARATION SCIENCE AND TECHNOLOGY, 2020, 55 (13) : 2303 - 2312