Evaluation of plan quality improvements in PlanIQ-guided Autoplanning

被引:21
|
作者
Perumal, Bojarajan [1 ,2 ]
Sundaresan, Harikrishna Etti [2 ]
Ranganathan, Vaitheeswaran [1 ]
Ramar, Natarajan [1 ,3 ]
Anto, Gipson Joe [1 ,2 ]
Meher, Samir Ranjan [3 ]
机构
[1] Philips India Ltd, Philips Hlth Syst, Bangalore, Karnataka, India
[2] Bharathiar Univ, Dept Med Phys, Coimbatore, Tamil Nadu, India
[3] Vellore Inst Technol, Sch Adv Sci, Dept Phys, Vellore, Tamil Nadu, India
关键词
IMRT; Autoplan (R); PlanIQ; Priori-Estimation of objectives; Optimization; VMAT; OPTIMIZATION; HEAD; DVH;
D O I
10.1016/j.rpor.2019.08.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aim: Philips recently integrated PlanlQwith Autoplan (R) in Pinnacle(3) TPS (V16.2). The objective of the present work is to quantitatively demonstrate how this integration improves the plan quality. Background: Pinnacle(3) Autoplan (R) is the tool that generates the treatment plans with clinically acceptable plan quality with less manual intervention. In the recent past, a new tool called PlanIQ (Sun Nuclear Corp.) was introduced for a priori estimation of the best possible sparing of an organ at risk (OAR) for a given patient anatomy. Philips has recently integrated PlanIQ tool with Autoplan (R) for a seamless and efficient planning workflow. Materials and methods: We have performed this evaluation in Pinnacle(3) TPS (V.16.2) for the VMAT treatment technique. All plans were created using Varian True beam machine with the dual arc technique. Basically, we created two sets of VMAT plans using 6 MV photons. In the first set of VMAT plans (AP_RTOG), we used OAR goals from either RTOG guidelines to perform optimization using Autoplan (R). Subsequently, we exported the same dataset to the PlanIQ system to perform feasibility analysis on the OAR goals. These newly obtained OAR goals from PlanIQ were used to generate the other set of plans (AP_PlanIQ plans). We compared the dosimetric results from these two sets of plans in five cases, such as brain, head & neck, lung, abdomen and prostate. Results: We compared the dosimetric results for AP_RTOG and AP_PlanIQ plans. We used RTOG guidelines to evaluate the plans and observed that while both sets of plans were meeting the RTOG guidelines in terms of OAR sparing, the AP_PlanIQplans were significantly better in terms of OAR sparing as compared to AP_RTOG plans without any compromise in the target coverage. Conclusion: The results indicate that, although Autoplan helps achieve the user-defined goals without much manual intervention, the plan quality (OAR sparing) can be significantly improved without taking many iterative steps when PlanIQ suggested clinical goals are used in the Autoplan-based optimization. Advances in knowledge: At present, there are no published material available about the efficacy of the integration of PlanIQ with Autoplanning (R). In the present work, our objective is to evaluate the improvements in plan quality resulting from this integration. (C) 2019 Greater Poland Cancer Centre. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:533 / 543
页数:11
相关论文
共 50 条
  • [31] An Automated Tool for Treatment Plan Quality Evaluation and Clinical Trial Quality Assurance
    Wang, J.
    Chen, W.
    Studenski, M.
    Cui, Y.
    Lee, A.
    Xiao, Y.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [32] Plan Quality And Fidelity Evaluation Of CBCT-Guided Stereotactic Online Adaptive Radiotherapy (CT-STAR) With An Artificial Intelligence (AI) Aided Plan Re-Optimization
    Hao, Y.
    Cai, B.
    Laugeman, E.
    Kim, T.
    Jiang, Z.
    Green, O. L.
    Kim, H.
    Robinson, C. G.
    Mutic, S.
    Hugo, G. D.
    Henke, L. E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E786 - E787
  • [33] Development of the DVH management software for the biologically-guided evaluation of radiotherapy plan
    Kim, BoKyong
    Park, Hee Chul
    Oh, Dongryul
    Shin, Eun Hyuk
    Ahn, Yong Chan
    Kim, Jinsung
    Han, Youngyih
    RADIATION ONCOLOGY JOURNAL, 2012, 30 (01): : 43 - 48
  • [34] Evaluation of plan quality based on a novel plan difficulty index and its preliminary application in radiotherapy
    Li, Qicheng
    Luo, Huanli
    Liu, Xianfeng
    Zhong, Mingsong
    Yang, Han
    Tao, Dan
    Jin, Fu
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2021, 14 (01) : 477 - 485
  • [35] Plan Quality Evaluation and Preliminary Application of a Novel Plan Difficulty Index in Radiotherapy of Lung Cancer
    Li, Q.
    Luo, H.
    Peng, H.
    Zhong, M.
    Liu, X.
    Qiu, D.
    Yang, H.
    He, Y.
    Li, C.
    Yin, L.
    Huang, X.
    Tian, X.
    He, G.
    Wang, Y.
    Jin, F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E743 - E743
  • [37] Measuring and Reporting Intercoder Reliability in Plan Quality Evaluation Research
    Stevens, Mark R.
    Lyles, Ward
    Berke, Philip R.
    JOURNAL OF PLANNING EDUCATION AND RESEARCH, 2014, 34 (01) : 77 - 93
  • [38] Adaptive Stereotactic Abdominal Plan Quality and Fidelity Evaluation on Ethos
    Laugeman, E.
    Hao, Y.
    Jiang, Z.
    Hugo, G.
    Mutic, S.
    Kim, H.
    Henke, L.
    Cai, B.
    MEDICAL PHYSICS, 2020, 47 (06) : E450 - E450
  • [39] Evaluation of plan quality in radiotherapy planning with an MR-linac
    van de Schoot, Agustinus J. A. J.
    van den Wollenberg, Wouter
    Carbaat, Casper
    de Ruiter, Peter
    Nowee, Marlies E.
    Pos, Floris
    van Triest, Baukelien
    Sonke, Jan-Jakob
    Janssen, Tomas M.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2019, 10 : 19 - 24
  • [40] A Novel Evaluation Model for the Plan Quality and Consistency for Cervical Cancer
    Tao, C.
    Li, C.
    Liu, T.
    Lu, J.
    MEDICAL PHYSICS, 2017, 44 (06) : 3053 - 3053