Evaluation of plan quality improvements in PlanIQ-guided Autoplanning

被引:21
|
作者
Perumal, Bojarajan [1 ,2 ]
Sundaresan, Harikrishna Etti [2 ]
Ranganathan, Vaitheeswaran [1 ]
Ramar, Natarajan [1 ,3 ]
Anto, Gipson Joe [1 ,2 ]
Meher, Samir Ranjan [3 ]
机构
[1] Philips India Ltd, Philips Hlth Syst, Bangalore, Karnataka, India
[2] Bharathiar Univ, Dept Med Phys, Coimbatore, Tamil Nadu, India
[3] Vellore Inst Technol, Sch Adv Sci, Dept Phys, Vellore, Tamil Nadu, India
关键词
IMRT; Autoplan (R); PlanIQ; Priori-Estimation of objectives; Optimization; VMAT; OPTIMIZATION; HEAD; DVH;
D O I
10.1016/j.rpor.2019.08.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aim: Philips recently integrated PlanlQwith Autoplan (R) in Pinnacle(3) TPS (V16.2). The objective of the present work is to quantitatively demonstrate how this integration improves the plan quality. Background: Pinnacle(3) Autoplan (R) is the tool that generates the treatment plans with clinically acceptable plan quality with less manual intervention. In the recent past, a new tool called PlanIQ (Sun Nuclear Corp.) was introduced for a priori estimation of the best possible sparing of an organ at risk (OAR) for a given patient anatomy. Philips has recently integrated PlanIQ tool with Autoplan (R) for a seamless and efficient planning workflow. Materials and methods: We have performed this evaluation in Pinnacle(3) TPS (V.16.2) for the VMAT treatment technique. All plans were created using Varian True beam machine with the dual arc technique. Basically, we created two sets of VMAT plans using 6 MV photons. In the first set of VMAT plans (AP_RTOG), we used OAR goals from either RTOG guidelines to perform optimization using Autoplan (R). Subsequently, we exported the same dataset to the PlanIQ system to perform feasibility analysis on the OAR goals. These newly obtained OAR goals from PlanIQ were used to generate the other set of plans (AP_PlanIQ plans). We compared the dosimetric results from these two sets of plans in five cases, such as brain, head & neck, lung, abdomen and prostate. Results: We compared the dosimetric results for AP_RTOG and AP_PlanIQ plans. We used RTOG guidelines to evaluate the plans and observed that while both sets of plans were meeting the RTOG guidelines in terms of OAR sparing, the AP_PlanIQplans were significantly better in terms of OAR sparing as compared to AP_RTOG plans without any compromise in the target coverage. Conclusion: The results indicate that, although Autoplan helps achieve the user-defined goals without much manual intervention, the plan quality (OAR sparing) can be significantly improved without taking many iterative steps when PlanIQ suggested clinical goals are used in the Autoplan-based optimization. Advances in knowledge: At present, there are no published material available about the efficacy of the integration of PlanIQ with Autoplanning (R). In the present work, our objective is to evaluate the improvements in plan quality resulting from this integration. (C) 2019 Greater Poland Cancer Centre. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:533 / 543
页数:11
相关论文
共 50 条
  • [1] Multi-centric Evaluation of Radiation Plan in the CNS - Determination of a Planning Score to objectify Plan Quality with PlanIQ™
    Weigel, R.
    Wolf, U.
    Wiezorek, T.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 : 126 - 127
  • [2] Comparison of PlanIQ and RapidPlan Modeling for Radiotherapy Plan Quality Assurance
    Geng, H.
    Zhong, H.
    Cheng, C.
    Huang, M.
    Ryu, S.
    Liao, Z.
    Yin, F.
    Gillin, M.
    Mohan, R.
    Xiao, Y.
    MEDICAL PHYSICS, 2017, 44 (06) : 3119 - 3119
  • [3] IMRT Plan Quality Assessment Using Pinnacle's Auto-Planning and Sun Nuclear Corporation's PlanIQ Plan Evaluation and Feasibility
    Esquivel, C.
    Patton, L.
    McInturf, R.
    Nunez, F.
    Robinson, G.
    MEDICAL PHYSICS, 2017, 44 (06) : 3120 - 3120
  • [4] Evaluation of PlanIQ Quality Algorithm to improve quality of treatment planning for prostate cancer
    Girardi, A.
    Gevaert, T.
    Jaudet, C.
    Coussement, G.
    Defauw, A.
    Boussaer, M.
    Burghelea, M.
    Dhont, J.
    Reynders, T.
    Engels, B.
    De Ridder, M.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S489 - S490
  • [5] Combining a Commercial Autoplanning Engine with Database Dose Predictions to Further Improve Plan Quality
    Robertson, S. P.
    Moore, J. A.
    Hui, X.
    DeWeese, T. L.
    Tran, P.
    Quon, H.
    Cheng, Z.
    Bzdusek, K.
    Kumar, P.
    McNutt, T. R.
    MEDICAL PHYSICS, 2016, 43 (06) : 3337 - 3338
  • [6] A longitudinal evaluation of improvements in radiotherapy treatment plan quality for head and neck cancer patients
    Tol, Jim P.
    Doornaert, Patricia
    Witte, Birgit I.
    Dahele, Max
    Slotman, Ben J.
    Verbakel, Wilko F. A. R.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 (02) : 337 - 343
  • [7] A longitudinal evaluation of improvements in treatment plan quality for lung cancer with volumetric modulated arc therapy
    Xia, Wenlong
    Liu, Zhiqiang
    Yan, Lingling
    Han, Fei
    Hu, Zhihui
    Tian, Yuan
    Cui, Weijie
    Ren, Wenting
    Guo, Chenlei
    Miao, Junjie
    Dai, Jianrong
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (06): : 33 - 43
  • [8] Evaluation of Cranial FSRT Plan Quality on a Magnetic Resonance Image Guided Linear Accelerator
    Snyder, K.
    Kim, J.
    Dolan, J.
    Huang, Y.
    Doemer, A.
    Wen, N.
    Chetty, I.
    Parikh, P.
    Shah, M.
    Siddiqui, S.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [9] From Quality Information to Quality Improvements: An Exploratory Study of Health Plan Actions
    Rosen, Bruce
    Nissanholtz, Rachel
    ACCOUNTABILITY AND RESPONSIBILITY IN HEALTH CARE: ISSUES IN ADDRESSING AN EMERGING GLOBAL CHALLENGE, 2012, 1 : 599 - 615
  • [10] The data quality improvement plan: deciding on choice and sequence of data quality improvements
    Dominikus Kleindienst
    Electronic Markets, 2017, 27 : 387 - 398