Adaptive temporal resolution optimization in helical cardiac cone beam CT reconstruction

被引:93
|
作者
Manzke, R [1 ]
Grass, M
Nielsen, T
Shechter, G
Hawkes, D
机构
[1] Philips Res Labs, Sector Tech Syst, Hamburg, Germany
[2] KCL, Imaging Sci Grp, London, England
[3] Philips Med Syst, Haifa, Israel
关键词
cardiac cone beam computed tomography; temporal resolution; optimization of approximate 3D reconstruction;
D O I
10.1118/1.1624756
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Cone beam computed tomography scanners in combination with heart rate adaptive reconstruction schemes have the potential to enable cardiac volumetric computed tomography (CT) imaging for a larger number of patients and applications. In this publication, an adaptive scheme for the automatic and patient-specific reconstruction optimization is introduced to improve the temporal resolution and image quality. The optimization method permits the automatic determination of the required amount of gated helical cone beam projection data for the reconstruction volume. It furthermore allows one to optimize subvolume reconstruction yielding an increased temporal resolution. In addition, methods for the assessment of the temporal resolution are given which enable a quantitative documentation of the reconstruction improvements. Results are presented for patient data sets acquired in low pitch helical mode using a 16-slice cone beam CT system with parallel ECG recording. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:3072 / 3080
页数:9
相关论文
共 50 条
  • [41] CEnPiT:: Helical cardiac CT reconstruction
    Bontus, Claas
    Koken, Peter
    Koehler, Thomas
    Grass, Michael
    MEDICAL PHYSICS, 2006, 33 (08) : 2792 - 2799
  • [42] A RECONSTRUCTION ALGORITHM FOR HELICAL CONE-BEAM SPECT
    WENG, Y
    ZENG, GL
    GULLBERG, GT
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) : 1092 - 1101
  • [43] Iterative Motion-Aware Reconstruction Algorithm for Cardiac Cone Beam CT
    Schomberg, Hermann
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4077 - 4079
  • [44] A rebinned backprojection-filtration algorithm for image reconstruction in helical cone-beam CT
    Yu, Lifeng
    Xia, Dan
    Zou, Yu
    Sidky, Emil Y.
    Bian, Junguo
    Pan, Xiaochuan
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (18): : 5497 - 5508
  • [45] Helical CT reconstruction from wide cone-beam angle data using ART
    Carvalho, BM
    Herman, GT
    XVI BRAZILIAN SYMPOSIUM ON COMPUTER GRAPHICS AND IMAGE PROCESSING, PROCEEDINGS, 2003, : 363 - 370
  • [46] Exact reconstruction for unequally spaced triple-source helical cone-beam CT
    Jin, Yannan
    Zhao, Jun
    Jiang, Ming
    Zhuang, Tiange
    Wang, Ge
    DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318
  • [47] High-resolution helical cone-beam micro-CT with theoretically-exact reconstruction from experimental data
    Varslot, T.
    Kingston, A.
    Myers, G.
    Sheppard, A.
    MEDICAL PHYSICS, 2011, 38 (10) : 5459 - 5476
  • [48] Application of dual-energy techniques to helical, cone-beam CT image reconstruction
    Sidky, E
    Zou, Y
    Pan, X
    MEDICAL PHYSICS, 2003, 30 (06) : 1408 - 1408
  • [49] Rebinned BPF reconstruction for helical cone-beam CT with half-cover scanning
    Zou X.-B.
    Zeng L.
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2010, 18 (09): : 2077 - 2085
  • [50] Iterative Helical Cone-Beam CT Reconstruction Using Graphics Hardware: A Simulation Study
    Pan, Yongsheng
    Whitaker, Ross
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961