The effect of postoperative anticoagulation on false lumen patency after surgery for acute type A aortic dissection

被引:1
|
作者
Larsson, Marten [1 ,2 ]
Bozovic, Gracijela [2 ,3 ]
Sjogren, Johan [1 ,2 ]
Zindovic, Igor [1 ,2 ]
Ragnarsson, Sigurdur [1 ,2 ]
Nozohoor, Shahab [1 ,2 ]
机构
[1] Lund Univ, Dept Clin Sci Lund, Cardiothorac Surg, Getingevagen 4, S-22185 Lund, Sweden
[2] Skane Univ Hosp, Getingevagen 4, S-22185 Lund, Sweden
[3] Lund Univ, Dept Med Imaging & Clin Physiol, Lund, Sweden
关键词
Aortic dissection; False lumen; Anticoagulation; TOTAL ARCH REPLACEMENT; HEMIARCH; FEATURES; REPAIR; TEAR; CT;
D O I
10.1186/s13019-021-01661-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Patent false lumen has been shown to have a negative impact on prognosis after surgery for acute type A aortic dissection (ATAAD). We aimed to assess the effect of postoperative anticoagulation on false lumen patency and clinical outcomes in relation to false lumen status. Methods Postoperative computed tomographies of 156 patients undergoing ATAAD DeBakey type I surgery were retrospectively evaluated for false lumen patency. The patients were divided into groups determined by anticoagulation treatment at discharge. Uni- and multivariable logistic regression was used for analysing the effect of anticoagulation on the false lumen, and Kaplan-Meier estimates were used to assess the association of a patent false lumen with the incidence of reoperation and long-term survival. Results A patent false lumen was present in 81% of the patients. Postoperative anticoagulants were not associated with a patent false lumen (p = 0.48) in univariable analysis. In multivariable analysis, both hemiarch replacement (OR 0.15, CI95% 0.05-0.49, p = 0.001) and the use of betablockers had a protective effect (OR 0.29, CI95% 0.10-0.85, p = 0.023). The Kaplan-Meier estimates for survival and the composite endpoint of survival and freedom from distal reintervention indicated no difference in outcome between patients in regard to anticoagulation treatment (survival p = 0.43, composite p = 0.82) or false lumen status (survival p = 0.21, composite p = 0.09). Conclusion This study could not show negative effects from the postoperative use of anticoagulants on false lumen status, nor that false lumen patency was associated with poorer prognosis. A hemiarch procedure was shown to be associated with reduced risk of false lumen patency.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Repair of an acute type a dissection: Fate of the remnant false lumen and preserved aortic valve
    Yukinori Moriyama
    Goichi Yotsumoto
    Hiroshi Masuda
    Yosihumi Iguro
    Shunichi Watanabe
    Koichi Hisatomi
    Riichiro Toda
    Shinji Shimokawa
    Hitoshi Toyohira
    Akira Taira
    Surgery Today, 1999, 29 : 413 - 418
  • [32] Repair of an acute type A dissection: Fate of the remnant false lumen and preserved aortic valve
    Moriyama, Y
    Yotsumoto, G
    Masuda, H
    Iguro, Y
    Watanabe, S
    Hisatomi, K
    Toda, R
    Shimokawa, S
    Toyohira, H
    Taira, A
    SURGERY TODAY-THE JAPANESE JOURNAL OF SURGERY, 1999, 29 (05): : 413 - 418
  • [33] Relationship between false lumen morphology and entry tear in acute type A aortic dissection
    Furui, Masato
    Uesugi, Noriko
    Matsumura, Hitoshi
    Hayashida, Yoshio
    Kuwahara, Go
    Fujii, Mitsuru
    Shimizu, Masayuki
    Morita, Yuichi
    Ito, Chihaya
    Hayama, Masato
    Wada, Hideichi
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2024, 65 (02)
  • [34] Total aortic arch grafting for acute type A dissection: Analysis of residual false lumen
    Takahara, Y
    Sudo, Y
    Mogi, K
    Nakayama, M
    Sakurai, M
    ANNALS OF THORACIC SURGERY, 2002, 73 (02): : 450 - 454
  • [35] Quick spontaneous remodelling of thrombosed false lumen in acute type-A aortic dissection
    Pinon, Miguel
    Acuna, Beatriz
    Lugo, Julio
    Pradas, Gonzalo
    JOURNAL OF THORACIC DISEASE, 2017, 9 (05) : 1366 - 1368
  • [36] Fate of the Patent False Lumen of the Descending Aorta After Surgical Treatment for Acute Type 1 Aortic Dissection
    Yasar, Emre
    Duman, Zihni Mert
    Timur, Baris
    Bayram, Muhammed
    Kaplan, Mustafa Can
    Kadirogullari, Ersin
    BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2023, 38 (06)
  • [37] Midterm Change of Descending Aortic False Lumen After Repair of Acute Type I Dissection INVITED COMMENTARY
    Miyamoto, Shinji
    ANNALS OF THORACIC SURGERY, 2009, 87 (01): : 108 - 108
  • [38] The role of false lumen size in prediction of in-hospital complications after acute type B aortic dissection
    Chang, Chih-Ping
    Liu, Juhn-Cherng
    Liou, Ying-Ming
    Chang, Shih-Sheng
    Chen, Jan-Yow
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (14) : 1170 - 1176
  • [39] Prevention of antegrade flow into the false lumen in acute aortic dissection
    Fujii, H
    Koide, S
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 122 (02): : 404 - 405
  • [40] Influence of distal extension of false lumen on adverse aortic events after TEVAR in patients with acute type B aortic dissection
    Du Zhan-kui
    Wang Ya
    Wang Xiao-zeng
    Jing Quan-min
    Han Ya-ling
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2016, 87 : 599 - 607