The effect of postoperative anticoagulation on false lumen patency after surgery for acute type A aortic dissection

被引:1
|
作者
Larsson, Marten [1 ,2 ]
Bozovic, Gracijela [2 ,3 ]
Sjogren, Johan [1 ,2 ]
Zindovic, Igor [1 ,2 ]
Ragnarsson, Sigurdur [1 ,2 ]
Nozohoor, Shahab [1 ,2 ]
机构
[1] Lund Univ, Dept Clin Sci Lund, Cardiothorac Surg, Getingevagen 4, S-22185 Lund, Sweden
[2] Skane Univ Hosp, Getingevagen 4, S-22185 Lund, Sweden
[3] Lund Univ, Dept Med Imaging & Clin Physiol, Lund, Sweden
关键词
Aortic dissection; False lumen; Anticoagulation; TOTAL ARCH REPLACEMENT; HEMIARCH; FEATURES; REPAIR; TEAR; CT;
D O I
10.1186/s13019-021-01661-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Patent false lumen has been shown to have a negative impact on prognosis after surgery for acute type A aortic dissection (ATAAD). We aimed to assess the effect of postoperative anticoagulation on false lumen patency and clinical outcomes in relation to false lumen status. Methods Postoperative computed tomographies of 156 patients undergoing ATAAD DeBakey type I surgery were retrospectively evaluated for false lumen patency. The patients were divided into groups determined by anticoagulation treatment at discharge. Uni- and multivariable logistic regression was used for analysing the effect of anticoagulation on the false lumen, and Kaplan-Meier estimates were used to assess the association of a patent false lumen with the incidence of reoperation and long-term survival. Results A patent false lumen was present in 81% of the patients. Postoperative anticoagulants were not associated with a patent false lumen (p = 0.48) in univariable analysis. In multivariable analysis, both hemiarch replacement (OR 0.15, CI95% 0.05-0.49, p = 0.001) and the use of betablockers had a protective effect (OR 0.29, CI95% 0.10-0.85, p = 0.023). The Kaplan-Meier estimates for survival and the composite endpoint of survival and freedom from distal reintervention indicated no difference in outcome between patients in regard to anticoagulation treatment (survival p = 0.43, composite p = 0.82) or false lumen status (survival p = 0.21, composite p = 0.09). Conclusion This study could not show negative effects from the postoperative use of anticoagulants on false lumen status, nor that false lumen patency was associated with poorer prognosis. A hemiarch procedure was shown to be associated with reduced risk of false lumen patency.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] High pressure in the false lumen favors secondary dilatation of the aorta after acute type A aortic dissection
    Immer, FF
    Hagen, U
    Berdat, PA
    Eckstein, FS
    Schmidli, J
    Carrel, TP
    CIRCULATION, 2004, 110 (17) : 671 - 671
  • [22] Role of False Lumen Area Ratio in Late Aortic Events After Acute Type I Aortic Dissection Repair
    Kim, Jung-Hwan
    Lee, Seung Hyun
    Lee, Sak
    Youn, Young-Nam
    Yoo, Kyung-Jong
    Joo, Hyun-Chel
    ANNALS OF THORACIC SURGERY, 2022, 114 (06): : 2217 - 2224
  • [23] Inconsistent False Lumen Enhancement Predicts Late Aortic Events After Hemiarch Replacement in Acute Type A Aortic Dissection
    Nishida, Hidefumi
    Nakamura, Ryota
    Tamaki, Rihito
    Abe, Kohei
    AMERICAN JOURNAL OF CARDIOLOGY, 2024, 221 : 77 - 83
  • [24] Acute Aortic Occlusion Due to False-Lumen Expansion After Repair of Abdominal Aortic Rupture in Type B Acute Aortic Dissection
    Yamamoto, Hiroshi
    Yamamoto, Fumio
    Izumoto, Hiroshi
    Shiroto, Keisuke
    Tanaka, Fuminobu
    Yamaura, Gembu
    Motokawa, Mamika
    Ishibashi, Kazuyuki
    ANNALS OF VASCULAR SURGERY, 2010, 24 (07) : 951.e1 - 951.e6
  • [25] Influence of Patent False Lumen on Secondary Dilation of the Distal Aorta Following Surgery for Acute Type A Aortic Dissection
    Kimura, Naoyuki
    Tanaka, Masashi
    Adachi, Hideo
    Yamaguchi, Atsushi
    Ino, Takashi
    ADVANCES IN UNDERSTANDING AORTIC DISEASES, 2009, : 197 - 197
  • [26] Outer Media Thickness at False Lumen and Secondary Aortic Dilatation After Acute Aortic Dissection
    Kinoshita, Takeshi
    Asai, Tohru
    Suzuki, Tomoaki
    ANNALS OF THORACIC SURGERY, 2022, 114 (05): : 1646 - 1654
  • [27] Flow dynamics in the false lumen in distal aorta following surgery for type A aortic dissection
    Desai, Dhaval
    Miranda, William
    Connolly, Heidi
    Tajik, A. Jamil
    EUROPEAN HEART JOURNAL, 2019, 40 (06) : 561 - 561
  • [28] Effect of Endovascular Treatment on the Pressure in the False Lumen of Type B Aortic Dissection
    Gokalp, Orhan
    Yesilkaya, Nihan Karakas
    Iner, Hasan
    Besir, Yuksel
    Gokalp, Gamze
    Yilik, Levent
    Gurbuz, Ali
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2019, 58 (04) : 629 - 629
  • [29] Long-term outcome of the false lumen after surgery of acute type A dissection of the aorta.
    Dubar, A
    Beregi, JP
    Bouchard, F
    Warembourg, H
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1998, 91 (01): : 39 - 44
  • [30] Surgery of Aortic Dissection: How to Promote False Lumen Thrombosis
    Dammrau, Rolf A.
    JOURNAL OF VASCULAR SURGERY, 2023, 77 (04) : 58S - 59S