Measurement of cranio-caudal catheter displacement between fractions in CT-based HDR brachytherapy of prostate cancer

被引:1
|
作者
Kim, Y [1 ]
Hsu, I [1 ]
Pouliot, J [1 ]
机构
[1] Univ Calif San Francisco, San Francisco, CA 94143 USA
关键词
D O I
10.1118/1.1997708
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To measure the cranio‐caudal displacement of catheters occurring between consecutive fractions of transrectal ultrasound (TRUS) guided high dose rate (HDR) prostate brachytherapy. Method and Materials: Ten consecutive patients were treated with 2 fractions of 9.5 Gy TRUS guided HDR brachytherapy using dental putty for the fixation of catheters. For each patient, a CT scan with 3 mm slice thickness was acquired before each of the two fractions. Two different references were employed to measure the catheter displacement between fractions: the ischial bone as a bony marker (BM) and the center of two gold markers (COGM) implanted in the prostate. The catheter displacement was calculated by multiplying the thickness of CT slice with the difference in number of CT slices between the reference slice and the slice containing the tip of a catheter. Results: The average (range) magnitude of caudal catheter displacement was 4.1 mm: 2.7 mm (−6.0 to 13.5 mm) for BM method and 5.4 mm (−3.75 to 18.0 mm) for COGM method, respectively. The measurement results obtained from BM and COGM methods verified that both prostate movement and catheter displacement independently occurred between fractions. The most anterior and medial two catheters (catheter position 8 and 12) had the greatest tendency to be displaced in the caudal direction because they were located at the most distant position from the fulcrum, susceptible to the rotation of the dental putty in lateral plane due to patient movement between fractions. Conclusion: The catheter displacement using dental putty for the fixation of catheters is smaller than the conventional technique using pre‐fabricated template. The use of both BM and COGM methods for catheter displacement measurement can demonstrate the prostate movement relative to the catheter displacement between fractions. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1957 / 1957
页数:1
相关论文
共 50 条
  • [31] A Pilot Study of Catheter-Based Ultrasound Hyperthermia with HDR Brachytherapy for Treatment of Locally Advanced Cancer of the Prostate and Cervix
    Diederich, Chris J.
    Wootton, Jeff
    Prakash, Punit
    Salgaonkar, Vasant
    Juang, Titania
    Scott, Serena
    Chen, Xin
    Cunha, Adam
    Pouliot, Jean
    Hsu, I. C.
    10TH INTERNATIONAL SYMPOSIUM ON THERAPEUTIC ULTRASOUND (ISTU 2010), 2011, 1359 : 195 - 199
  • [32] Dose uncertainty due to computed tomography (CT) slice thickness in CT-based high dose rate brachytherapy of the prostate cancer
    Kim, Y
    Hsu, ICJ
    Lessard, E
    Pouliot, J
    Vujic, J
    MEDICAL PHYSICS, 2004, 31 (09) : 2543 - 2548
  • [33] A Retrospective Study Investigating the Use of the First Fraction CT-Based Treatment Planning to Deliver Subsequent Fractions for High-Dose-Rate (HDR) Brachytherapy of the Cervix
    Awotwi-Pratt, J. B.
    Pastuch, A.
    Bachand, F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E318 - E319
  • [34] New interstitial HDR brachytherapy technique for prostate cancer: CT based 3D planning after transrectal implantation
    Martin, T
    Kolotas, C
    Dannenberg, T
    Strassmann, G
    Vogt, HG
    Heyd, R
    Rogge, B
    Baltas, D
    Kurek, R
    Tunn, U
    Zamboglou, N
    RADIOTHERAPY AND ONCOLOGY, 1999, 52 (03) : 257 - 260
  • [35] Assessment of the Anatomical Position of Point B and the Relationship Between Point B Dose and the Dose Delivered to Pelvic Lymph Nodes in CT-Based HDR Brachytherapy for Uterine Cervical Cancer
    Matsukawa, H.
    Sasaki, T.
    Hirayama, R.
    Hirose, T.
    Fukunaga, J.
    MEDICAL PHYSICS, 2018, 45 (06) : E245 - E245
  • [36] CT-based Inverse Treatment Planning In HDR-intracavitary Brachytherapy for Cervical Cancer: Impact of Point A and Target-based Dosimetric and Dose Prescription Methods
    Madan, R.
    Subramani, V.
    Pathy, S.
    Sharma, S.
    Manigandan, D.
    Kumar, M. Sujith
    Mohanti, B. K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S422 - S423
  • [37] Prostate cancer brachytherapy: Is real-time ultrasound (US) based dosimetry predictive of the subsequent CT-based dose distribution calculation
    Chauveinc, L
    Flam, T
    Solignac, S
    Thiounn, N
    Firmin, F
    Debre, B
    RADIOLOGY, 2002, 225 : 266 - 266
  • [38] Modeling correlation indices between bladder and Foleys catheter balloon dose with CT-based planning using limited CT slices in intracavitary brachytherapy for carcinoma of cervix
    Oinam, Arun S.
    Goda, Jayant Sastri
    Dubey, Sidharth
    Bhardwaj, Anup
    Patel, Firuza D.
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2008, 4 (04) : 156 - 163
  • [39] Correlation Between Bladder Volume and Irradiated Dose of Small Bowel in CT-based Planning of Intracavitary Brachytherapy for Cervical Cancer
    Yamashita, Hideomi
    Nakagawa, Keiichi
    Okuma, Kae
    Sakumi, Akira
    Haga, Akihiro
    Kobayashi, Reiko
    Ohtomo, Kuni
    JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2012, 42 (04) : 302 - 308
  • [40] Intraoperative ultrasound-based planning can effectively replace postoperative CT-based planning for high-dose-rate brachytherapy for prostate cancer
    Batchelar, Deidre L.
    Chung, Hans T.
    Loblaw, Andrew
    Law, Niki
    Cisecki, Thomas
    Morton, Gerard C.
    BRACHYTHERAPY, 2016, 15 (04) : 399 - 405