Measurement of cranio-caudal catheter displacement between fractions in CT-based HDR brachytherapy of prostate cancer

被引:1
|
作者
Kim, Y [1 ]
Hsu, I [1 ]
Pouliot, J [1 ]
机构
[1] Univ Calif San Francisco, San Francisco, CA 94143 USA
关键词
D O I
10.1118/1.1997708
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To measure the cranio‐caudal displacement of catheters occurring between consecutive fractions of transrectal ultrasound (TRUS) guided high dose rate (HDR) prostate brachytherapy. Method and Materials: Ten consecutive patients were treated with 2 fractions of 9.5 Gy TRUS guided HDR brachytherapy using dental putty for the fixation of catheters. For each patient, a CT scan with 3 mm slice thickness was acquired before each of the two fractions. Two different references were employed to measure the catheter displacement between fractions: the ischial bone as a bony marker (BM) and the center of two gold markers (COGM) implanted in the prostate. The catheter displacement was calculated by multiplying the thickness of CT slice with the difference in number of CT slices between the reference slice and the slice containing the tip of a catheter. Results: The average (range) magnitude of caudal catheter displacement was 4.1 mm: 2.7 mm (−6.0 to 13.5 mm) for BM method and 5.4 mm (−3.75 to 18.0 mm) for COGM method, respectively. The measurement results obtained from BM and COGM methods verified that both prostate movement and catheter displacement independently occurred between fractions. The most anterior and medial two catheters (catheter position 8 and 12) had the greatest tendency to be displaced in the caudal direction because they were located at the most distant position from the fulcrum, susceptible to the rotation of the dental putty in lateral plane due to patient movement between fractions. Conclusion: The catheter displacement using dental putty for the fixation of catheters is smaller than the conventional technique using pre‐fabricated template. The use of both BM and COGM methods for catheter displacement measurement can demonstrate the prostate movement relative to the catheter displacement between fractions. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1957 / 1957
页数:1
相关论文
共 50 条
  • [21] High dose rate afterloading brachytherapy for prostate cancer: catheter and gland movement between fractions
    Hoskin, PJ
    Bownes, PJ
    Ostler, P
    Walker, K
    Bryant, L
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 (03) : 285 - 288
  • [22] Catheter-based ultrasound hyperthermia with HDR brachytherapy for treatment of locally advanced cancer of the prostate and cervix
    Diederich, Chris J.
    Wootton, Jeff
    Prakash, Punit
    Salgaonkar, Vasant
    Juang, Titania
    Scott, Serena
    Chen, Xin
    Cunha, Adam
    Pouliot, Jean
    Hsu, I. C.
    ENERGY-BASED TREATMENT OF TISSUE AND ASSESSMENT VI, 2011, 7901
  • [23] Comparison of orthogonal radiography and 3D CT-based treatment planning in HDR brachytherapy of cervix cancer
    Alezra, D.
    Rabin, T.
    Levin, D.
    Menchel, J.
    Symon, Z.
    Pfeffer, R.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S323 - S323
  • [24] Comparison of orthogonal radiography and 3D CT-based treatment planning in HDR brachytherapy of cervix cancer
    Alezra, D.
    Rabin, T.
    Levine, D.
    Menhel, J.
    Symon, Z.
    Pfeffer, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S407 - S408
  • [25] Contour-Based Deformable Image Registration and Dose Accumulation in CT-based Hybrid HDR Brachytherapy for Cervical Cancer
    Shen, X.
    Velten, C.
    Hsu, S. H.
    Basavatia, A.
    Mehta, K. J.
    Tome, W. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E339 - E340
  • [26] Effect of a urinary catheter on seed position and rectal and bladder doses in CT-based post-implant dosimetry for prostate cancer brachytherapy
    Kunogi, Hirooki
    Yamaguchi, Nanae
    Wokumoto, Yoshiaki
    Sosoi, Keisuke
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2015, 7 (03) : 211 - 217
  • [27] CT-based intra-cavitary high dose rate (HDR) brachytherapy for cervical cancer: planning and QA
    Wang, B.
    Zhu, Y.
    Yeo, I.
    Kwon, A.
    Henson, C.
    MEDICAL PHYSICS, 2007, 34 (06) : 2431 - 2431
  • [28] Improved the Accuracy of Prostate Delineation for Ultrasound-Guided CT-Based Treatment Planning in Prostate HDR Brachytherapy: A Pilot Study with MRI Validation
    Yang, X.
    Rossi, P.
    Ogunleye, T.
    Curran, W.
    Liu, T.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [29] Utrecht Intertitial Applicator Shifts and Organ Movements in 3D CT-Based HDR Brachytherapy of Cervical Cancer
    Cheng, H. G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S835 - S836
  • [30] Feasibility of using micro silica bead TLDs for in-Vivo dosimetry of CT-based HDR prostate brachytherapy: An experimental and simulation study
    Siavashpour, Zahra
    Kiarad, Reza
    Aghamiri, Mahmoud Reza
    Babaloui, Somayyeh
    Seiri, Mahnaz
    Jaberi, Ramin
    APPLIED RADIATION AND ISOTOPES, 2024, 212