Measurement of cranio-caudal catheter displacement between fractions in CT-based HDR brachytherapy of prostate cancer

被引:1
|
作者
Kim, Y [1 ]
Hsu, I [1 ]
Pouliot, J [1 ]
机构
[1] Univ Calif San Francisco, San Francisco, CA 94143 USA
关键词
D O I
10.1118/1.1997708
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To measure the cranio‐caudal displacement of catheters occurring between consecutive fractions of transrectal ultrasound (TRUS) guided high dose rate (HDR) prostate brachytherapy. Method and Materials: Ten consecutive patients were treated with 2 fractions of 9.5 Gy TRUS guided HDR brachytherapy using dental putty for the fixation of catheters. For each patient, a CT scan with 3 mm slice thickness was acquired before each of the two fractions. Two different references were employed to measure the catheter displacement between fractions: the ischial bone as a bony marker (BM) and the center of two gold markers (COGM) implanted in the prostate. The catheter displacement was calculated by multiplying the thickness of CT slice with the difference in number of CT slices between the reference slice and the slice containing the tip of a catheter. Results: The average (range) magnitude of caudal catheter displacement was 4.1 mm: 2.7 mm (−6.0 to 13.5 mm) for BM method and 5.4 mm (−3.75 to 18.0 mm) for COGM method, respectively. The measurement results obtained from BM and COGM methods verified that both prostate movement and catheter displacement independently occurred between fractions. The most anterior and medial two catheters (catheter position 8 and 12) had the greatest tendency to be displaced in the caudal direction because they were located at the most distant position from the fulcrum, susceptible to the rotation of the dental putty in lateral plane due to patient movement between fractions. Conclusion: The catheter displacement using dental putty for the fixation of catheters is smaller than the conventional technique using pre‐fabricated template. The use of both BM and COGM methods for catheter displacement measurement can demonstrate the prostate movement relative to the catheter displacement between fractions. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1957 / 1957
页数:1
相关论文
共 50 条
  • [1] Dosimetric impact of prostate volume change between CT-based HDR brachytherapy fractions
    Kim, Y
    Hsu, IC
    Lessard, E
    Vujic, J
    Pouliot, J
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (04): : 1208 - 1216
  • [2] Prostate volume change and dosimetric impact of edema between CT-based HDR brachytherapy fractions
    Kim, Y
    Hsu, I
    Lessard, E
    Pouliot, J
    MEDICAL PHYSICS, 2003, 30 (06) : 1389 - 1389
  • [3] A New CT Prostate Segmentation for CT-Based HDR Brachytherapy
    Yang, Xiaofeng
    Rossi, Peter
    Ogunleye, Tomi
    Jani, Ashesh B.
    Curran, Walter J.
    Liu, Tian
    MEDICAL IMAGING 2014: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2014, 9036
  • [4] Prostate HDR brachytherapy catheter displacement between planning and treatment delivery
    Whitaker, May
    Hruby, George
    Lovett, Aimee
    Patanjali, Nitya
    RADIOTHERAPY AND ONCOLOGY, 2011, 101 (03) : 490 - 494
  • [5] Measurement of craniocaudal catheter displacement between fractions in computed tomography-based high dose rate brachytherapy of prostate cancer
    Kim, Yongbok
    Hsu, I-Chow J.
    Pouliot, Jean
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2007, 8 (04): : 1 - 13
  • [6] Illustrating the Workflow of a Robust, CT-Based HDR Prostate Brachytherapy Program
    Manigold, R.
    MEDICAL PHYSICS, 2019, 46 (06) : E552 - E552
  • [7] CT-based HDR brachytherapy for salvage prostate cancer: the way to avoid or delay hormonal treatment
    Dunnewold, N.
    Kouwenhoven, E.
    Koper, P.
    Van den Berg, S.
    Van der Klein, J.
    Noordermeer, J.
    Tak-Nobel, N.
    Van Wingerden, K.
    Mast, M.
    De Jager, H.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S616 - S617
  • [8] Dose uncertainty due to CT slice thickness in CT-Based HDR brachytherapy of the prostate
    Kim, Y
    Hsu, I
    Lessard, E
    Pouliot, J
    MEDICAL PHYSICS, 2002, 29 (06) : 1223 - 1223
  • [9] CT-based HDR brachytherapy for cervical cancer: Correlation between dose volume parameters and telangiectasia
    Koom, W.
    Sohn, D.
    Park, S.
    Kim, J.
    Kim, D.
    Shin, K.
    Cho, K.
    Kim, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S400 - S400
  • [10] Prostate CT segmentation method based on nonrigid registration in ultrasound-guided CT-based HDR prostate brachytherapy
    Yang, Xiaofeng
    Rossi, Peter
    Ogunleye, Tomi
    Marcus, David M.
    Jani, Ashesh B.
    Mao, Hui
    Curran, Walter J.
    Liu, Tian
    MEDICAL PHYSICS, 2014, 41 (11)