RECEIVE COIL ARRAY FOR MAGNETIC PARTICLE IMAGING

被引:0
|
作者
Knopp, Tobias [1 ]
Sattel, Timo F. [1 ]
Biederer, Sven [1 ]
Weizenecker, Juergen [2 ,3 ]
Gleich, Bernhard [2 ]
Borgert, Joern [2 ]
Buzug, Thorsten M. [1 ]
机构
[1] Med Univ Lubeck, Inst Med Engn, D-23538 Lubeck, Germany
[2] Philips Technologie GmbH, Forschungslab, Hamburg, Germany
[3] Univ Appl Sci Karlsruhe, Karlsruhe, Germany
关键词
magnetic particle imaging; receive coil array; parallel imaging; patient noise model; SENSITIVITY;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Magnetic particle imaging (MPI) is a quantitative method for determining the spatial distribution of superparamagnetic nanoparticles in-vivo. It applies various static and dynamic magnetic fields resulting in a spatially dependent particle magnetization characteristic, which can be recorded using receive coils. For spatial encoding, different field topologies were developed, which use either a point-based or a line-based acquisition scheme. The receive coil topology was, however, not changed since the first introduction of MPI in 2005. Therefore, the aim of this work is to investigate in a simulation study the role of the receive coils in MPI. Analogue to parallel imaging in magnetic resonance imaging, multiple receive coils are used and it is exploited, whether this allows to shorten the data acquisition time. In order to perform a realistic simulation study, a new method for modeling patient noise in MPI is proposed, which can be used even for non-orthogonal receive coils.
引用
收藏
页码:1666 / 1669
页数:4
相关论文
共 50 条
  • [41] Nineteen-Channel Receive Array and Four-Channel Transmit Array Coil for Cervical Spinal Cord Imaging at 7T
    Zhao, Wei
    Cohen-Adad, Julien
    Polimeni, Jonathan R.
    Keil, Boris
    Guerin, Bastien
    Setsompop, Kawin
    Serano, Peter
    Mareyam, Azma
    Hoecht, Philipp
    Wald, Lawrence L.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (01) : 291 - 300
  • [42] Excitation Coil Design for Single-Sided Magnetic Particle Imaging Scanner
    Sadiq, Abdulkadir Abubakar
    Othman, Nurmiza Binti
    Jamil, Muhammad Mahadi Abdul
    2016 IEEE ASIA-PACIFIC CONFERENCE ON APPLIED ELECTROMAGNETICS (APACE), 2016,
  • [43] Application of Highly Flexible Adaptive Image Receive Coil for Lung MR Imaging Using Zero TE Sequence: Comparison with Conventional Anterior Array Coil
    Bae, Kyungsoo
    Jeon, Kyung Nyeo
    Hwang, Moon Jung
    Jung, Yunsub
    Lee, Joonsung
    DIAGNOSTICS, 2022, 12 (01)
  • [44] Reconfigurable dipole receive array for dynamic parallel imaging at ultra-high magnetic field
    Nikulin, Anton V.
    Glang, Felix
    Avdievich, Nikolai I.
    Bosch, Dario
    Steffen, Theodor
    Scheffler, Klaus
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (04) : 1713 - 1727
  • [45] Transceive surface coil array for magnetic resonance imaging of the human brain at 4 T
    Pinkerton, RG
    Barberi, EA
    Menon, RS
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (02) : 499 - 503
  • [46] A DECOUPLED COIL DETECTOR ARRAY FOR FAST IMAGE ACQUISITION IN MAGNETIC-RESONANCE-IMAGING
    KWIAT, D
    EINAV, S
    NAVON, G
    MEDICAL PHYSICS, 1991, 18 (02) : 251 - 265
  • [47] Validation of a New Coil Array Tailored for Dog Functional Magnetic Resonance Imaging Studies
    Guran, Catherine-Noemie Alexandrina
    Sladky, Ronald
    Karl, Sabrina
    Boch, Magdalena
    Laistler, Elmar
    Windischberger, Christian
    Huber, Ludwig
    Lamm, Claus
    ENEURO, 2023, 10 (03)
  • [48] Increase the Signal-to-Noise Ratio of Magnetic Resonance Imaging by a Vertical Coil Array
    Liang, Dandan
    Hui, Hon Tat
    Yeo, Tat Soon
    2012 IEEE ASIA-PACIFIC CONFERENCE ON ANTENNAS AND PROPAGATION (APCAP), 2012, : 311 - 312
  • [49] Two-slotted surface coil array for magnetic resonance imaging at 4 tesla
    Solis, S. E.
    Hernandez, J. A.
    Tomasi, D.
    Rodriguez, A. O.
    MEDICAL PHYSICS, 2008, 1032 : 152 - +
  • [50] 64-channel array coil for single echo acquisition magnetic resonance imaging
    McDougall, MP