Concepts and Tradeoffs in Velocity Estimation With Plane-Wave Contrast-Enhanced Doppler

被引:12
|
作者
Tremblay-Darveau, Charles [1 ,2 ]
Williams, Ross [2 ]
Sheeran, Paul S. [1 ,2 ]
Milot, Laurent [2 ,3 ]
Bruce, Matthew [4 ,5 ]
Burns, Peter N. [1 ,2 ]
机构
[1] Univ Toronto, Dept Med Biophys, Toronto, ON M5G 1L7, Canada
[2] Sunnybrook Hlth Sci Ctr, Sunnybrook Res Inst, Toronto, ON M4N 3M5, Canada
[3] Univ Toronto, Dept Med Imaging, Toronto, ON M4N 3M5, Canada
[4] Univ Washington, Ctr Ind & Med Ultrasound, Seattle, WA 98105 USA
[5] Superson Imagine, Aix En Provence, France
基金
加拿大自然科学与工程研究理事会; 加拿大健康研究院;
关键词
Autocorrelators; blood velocity; Doppler; microbubbles; plane-wave ultrasound; CORONARY FLOW RESERVE; ULTRASOUND; AUTOCORRELATION; PERFUSION; TRACKING; MODEL;
D O I
10.1109/TUFFC.2016.2596581
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
While long Doppler ensembles are, in principle, beneficial for velocity estimates, short acoustic pulses must be used in microbubble contrast-enhanced (CE) Doppler to mitigate microbubble destruction. This introduces inherent tradeoffs in velocity estimates with autocorrelators, which are studied here. A model of the autocorrelation function adapted to the microbubble Doppler signal accounting for transit time, the echo frequency uncertainty, and contrast-agent destruction is derived and validated in vitro. It is further demonstrated that a local measurement of the center frequency of the microbubble echo is essential in order to avoid significant bias in velocity estimates arising from the linear and nonlinear frequency-dependent scattering of microbubbles and compensate for the inherent speckle nature of the received echo frequency. For these reasons, broadband Doppler estimators (2-D autocorrelator and Radon projection) are better suited than simpler narrow-band estimators (1-D autocorrelator and 1-D Fourier transform) for CE flow assessment. A case study of perfusion in a VX-2 carcinoma using CE plane-wave Doppler is also shown. We demonstrate that even when considering all uncertainties associated with microbubble-related decorrelation (destruction, pulse bandwidth, transit time, and flow gradient) and the need for real-time imaging, a coefficient of variation of 4% on the axial velocity is achievable with plane-wave imaging.
引用
收藏
页码:1890 / 1905
页数:16
相关论文
共 50 条
  • [31] Contrast-enhanced power Doppler US in the diagnosis of acute appendicitis
    Incesu, L
    Yazicioglu, AK
    Selcuk, MB
    Ozen, N
    EUROPEAN JOURNAL OF RADIOLOGY, 2004, 50 (02) : 201 - 209
  • [32] Contrast-enhanced Doppler perfusion index - Clinical and experimental evaluation
    Ramnarine, KV
    Leen, E
    Oppo, K
    Angerson, WJ
    McArdle, CS
    JOURNAL OF ULTRASOUND IN MEDICINE, 2002, 21 (10) : 1121 - 1129
  • [33] Value of contrast-enhanced power Doppler sonography using a microbubble
    Kook, SH
    Kwag, HJ
    JOURNAL OF CLINICAL ULTRASOUND, 2003, 31 (05) : 227 - 238
  • [34] Prostatic Perfusion in the Dog Using Contrast-Enhanced Doppler Ultrasound
    Russo, M.
    Vignoli, M.
    Catone, G.
    Rossi, F.
    Attanasi, G.
    England, G. C. W.
    REPRODUCTION IN DOMESTIC ANIMALS, 2009, 44 : 334 - 335
  • [35] Contrast-enhanced color doppler ultrasonography in suspected parathyroid lesions
    Mazzeo, S
    Caramella, D
    Marcocci, C
    Lonzi, S
    Cambi, L
    Miccoli, P
    Pinchera, A
    Bartolozzi, C
    ACTA RADIOLOGICA, 2000, 41 (05) : 412 - 416
  • [36] Testicular torsion: Usefulness of contrast-enhanced power Doppler sonography
    Yamaguchi, A
    Hayashi, Y
    Kojima, Y
    Miyagawa, H
    Ito, M
    Kohri, K
    INTERNATIONAL JOURNAL OF UROLOGY, 2005, 12 (09) : 849 - 851
  • [37] Renal infarct:: Contrast-enhanced power Doppler sonographic findings
    Yücel, C
    Özdemir, H
    Akpek, S
    Gürel, K
    Kapucu, LÖ
    Araç, M
    JOURNAL OF CLINICAL ULTRASOUND, 2001, 29 (04) : 237 - 242
  • [38] Contrast-enhanced transcranial Doppler ultrasonography in the diagnosis of brain death
    Welschehold, Stefan
    Geisel, Florian
    Beyer, Christian
    Reuland, Andre
    Kerz, Thomas
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2013, 84 (08): : 939 - +
  • [39] Contrast-enhanced power Doppler US in the diagnosis of acute appendicitis
    Incesu, L
    Yazicioglu, AK
    Selcuk, MB
    RADIOLOGY, 2001, 221 : 186 - 186
  • [40] Doppler and Contrast-Enhanced Ultrasonography of Testicles in Adult Domestic Felines
    de Brito, M. B. S.
    Feliciano, M. A. R.
    Coutinho, L. N.
    Uscategui, R. R.
    Simoes, A. P. R.
    Maronezi, M. C.
    de Almeida, V. T.
    Crivelaro, R. M.
    Gasser, B.
    Pavan, L.
    Russiano, W. R.
    REPRODUCTION IN DOMESTIC ANIMALS, 2015, 50 (05) : 730 - 734