Concepts and Tradeoffs in Velocity Estimation With Plane-Wave Contrast-Enhanced Doppler

被引:12
|
作者
Tremblay-Darveau, Charles [1 ,2 ]
Williams, Ross [2 ]
Sheeran, Paul S. [1 ,2 ]
Milot, Laurent [2 ,3 ]
Bruce, Matthew [4 ,5 ]
Burns, Peter N. [1 ,2 ]
机构
[1] Univ Toronto, Dept Med Biophys, Toronto, ON M5G 1L7, Canada
[2] Sunnybrook Hlth Sci Ctr, Sunnybrook Res Inst, Toronto, ON M4N 3M5, Canada
[3] Univ Toronto, Dept Med Imaging, Toronto, ON M4N 3M5, Canada
[4] Univ Washington, Ctr Ind & Med Ultrasound, Seattle, WA 98105 USA
[5] Superson Imagine, Aix En Provence, France
基金
加拿大自然科学与工程研究理事会; 加拿大健康研究院;
关键词
Autocorrelators; blood velocity; Doppler; microbubbles; plane-wave ultrasound; CORONARY FLOW RESERVE; ULTRASOUND; AUTOCORRELATION; PERFUSION; TRACKING; MODEL;
D O I
10.1109/TUFFC.2016.2596581
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
While long Doppler ensembles are, in principle, beneficial for velocity estimates, short acoustic pulses must be used in microbubble contrast-enhanced (CE) Doppler to mitigate microbubble destruction. This introduces inherent tradeoffs in velocity estimates with autocorrelators, which are studied here. A model of the autocorrelation function adapted to the microbubble Doppler signal accounting for transit time, the echo frequency uncertainty, and contrast-agent destruction is derived and validated in vitro. It is further demonstrated that a local measurement of the center frequency of the microbubble echo is essential in order to avoid significant bias in velocity estimates arising from the linear and nonlinear frequency-dependent scattering of microbubbles and compensate for the inherent speckle nature of the received echo frequency. For these reasons, broadband Doppler estimators (2-D autocorrelator and Radon projection) are better suited than simpler narrow-band estimators (1-D autocorrelator and 1-D Fourier transform) for CE flow assessment. A case study of perfusion in a VX-2 carcinoma using CE plane-wave Doppler is also shown. We demonstrate that even when considering all uncertainties associated with microbubble-related decorrelation (destruction, pulse bandwidth, transit time, and flow gradient) and the need for real-time imaging, a coefficient of variation of 4% on the axial velocity is achievable with plane-wave imaging.
引用
收藏
页码:1890 / 1905
页数:16
相关论文
共 50 条
  • [21] Plane-wave based vector flow imaging: beamforming and velocity estimation loads in different processing scenarios
    Lenge, Matteo
    Ramalli, Alessandro
    Ricci, Stefano
    Tortoli, Piero
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [22] SPECTRA OF ULTRASOUND DOPPLER RESPONSE USING PLANE-WAVE COMPOUNDING TECHNIQUE
    Barannik, Evgen A.
    Hrytsenko, Mykhailo O.
    EAST EUROPEAN JOURNAL OF PHYSICS, 2024, (01): : 476 - 484
  • [23] Detection of Individual Microbubbles by Burst-Wave-Aided Contrast-Enhanced Active Doppler Ultrasonography
    Yoshida, Kenji
    Omura, Masaaki
    Tamura, Kazuki
    Hirata, Shinnosuke
    Yamaguchi, Tadashi
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2024, 71 (03) : 380 - 394
  • [24] Uncertainty estimation in dynamic contrast-enhanced MRI
    Garpebring, Anders
    Brynolfsson, Patrik
    Yu, Jun
    Wirestam, Ronnie
    Johansson, Adam
    Asklund, Thomas
    Karlsson, Mikael
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (04) : 992 - 1002
  • [25] Feasibility and Limitation of Parametric Perfusion Imaging based on Dynamic Contrast-enhanced Plane Wave Imaging
    Wang, Diya
    Zong, Yujin
    Xiao, Mengnan
    Xu, Shanshan
    Wan, Mingxi
    2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
  • [26] High-Frequency Multipulse, Plane-Wave Acoustic Contrast Imaging
    Ketterling, Jeffrey A.
    Silverman, Ronald H.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (05) : 934 - 942
  • [27] Contrast-enhanced color Doppler sonography of parotid gland tumors
    Helmut Steinhart
    Johannes Zenk
    Kirsten Sprang
    Allessandro Bozzato
    Heinrich Iro
    European Archives of Oto-Rhino-Laryngology, 2003, 260 : 344 - 348
  • [28] Contrast-enhanced color Doppler sonography of parotid gland tumors
    Steinhart, H
    Zenk, J
    Sprang, K
    Bozzato, A
    Iro, H
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2003, 260 (06) : 344 - 348
  • [29] Contrast-enhanced color Doppler sonography in the evaluation of prostate cancer
    Frauscher, F
    Helweg, G
    Gotwald, TF
    Klauser, A
    Janetschek, G
    Zur Nedden, D
    RADIOLOGY, 1998, 209P : 417 - 418
  • [30] Measurement of cerebral circulation time by contrast-enhanced Doppler sonography
    Hoffmann, O
    Weih, M
    Schreiber, S
    Einhäupl, KM
    Valdueza, JM
    Valdueza, M
    CEREBROVASCULAR DISEASES, 2000, 10 (02) : 142 - 146