Improved quantitation for PET/CT image reconstruction with system modeling and anatomical priors

被引:1
|
作者
Alessio, AM [1 ]
Kinahan, PE [1 ]
Lewellen, TK [1 ]
机构
[1] Univ Washington, Ctr Med, Imaging Res Lab, Seattle, WA 98195 USA
关键词
anatomical priors; PSF; segmentation; PET/CT; detector response; fully 3-D PET;
D O I
10.1117/12.595372
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
Accurate quantitation of PET tracer uptake levels in small tumors remains a challenge. This work uses an improved reconstruction algorithm to reduce the quantitative errors due to limited system resolution and due to necessary image noise reduction. We propose a method for finding and using the detection system response in the projection matrix of a statistical reconstruction algorithm. In addition we use aligned anatomical information, available in PET/CT scanners, to govern the penalty term applied during each image update. These improvements are combined with FORE rebinning in a clinically feasible algorithm for reconstructing fully 3D PET data. Simulated results show improved tumor bias and variance characteristics with the new algorithm.
引用
收藏
页码:695 / 703
页数:9
相关论文
共 50 条
  • [21] Benefits of Using a Spatially-Variant Penalty Strength With Anatomical Priors in PET Reconstruction
    Tsai, Yu-Jung
    Schramm, Georg
    Ahn, Sangtae
    Bousse, Alexandre
    Arridge, Simon
    Nuyts, Johan
    Hutton, Brian F.
    Stearns, Charles W.
    Thielemans, Kris
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (01) : 11 - 22
  • [22] Anatomical priors to improve image quality in small-animal SPECT/CT
    Wells, R. Glenn
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4319 - 4323
  • [23] PSF modeling and anatomical prior design for improved quantitative PET using a dedicated NeuroPET/CT
    Dutta, Joyita
    Li, Quanzheng
    Grogg, Kira
    Zhu, Xuping
    Huang, Chuan
    El Fakhri, Georges
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [24] Optimization of high definition PET/CT image reconstruction: A phantom validation for improved quantification
    Binzel, Katherine
    Zhang, Jun
    Knopp, Michael
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [25] Improving Quantitation in Serial PET/CT with Improved Image Registration and Intra-Patient Metabolic Correction
    Cannon, B.
    Schwartz, D.
    Moeller, B.
    Zhang, L.
    Dong, L.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [26] Anatomical-image aided PET reconstruction by the kernel method
    Hutchcroft, Will
    Wang, Guobao
    Qi, Jinyi
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [27] Spatially Variant Positron Range Modeling Derived from CT for PET Image Reconstruction
    Alessio, Adam
    MacDonald, Lawrence
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2912 - 2915
  • [28] CT-based attenuation correction in PET image reconstruction for the Gemini system
    Bai, CY
    Tung, CH
    Kolthammer, J
    Shao, L
    Brown, KM
    Zhao, Z
    Da Silva, AJ
    Ye, JH
    Gagnon, D
    Parma, M
    Walsh, E
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3082 - 3086
  • [29] Penalized maximum likelihood simultaneous longitudinal PET image reconstruction with difference-image priors
    Ellis, Sam
    Reader, Andrew J.
    MEDICAL PHYSICS, 2018, 45 (07) : 3001 - 3018
  • [30] PET/CT reconstruction study using 2 mm voxel size for improved image quality
    Rep, S.
    Tomse, P.
    Jensterle, L.
    Zaletel, K.
    Lezaic, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S500 - S500