Diurnal variation of corneal and corneal epithelial thickness measured using optical coherence tomography

被引:150
|
作者
Feng, YW [1 ]
Varikooty, J [1 ]
Simpson, TL [1 ]
机构
[1] Univ Waterloo, Sch Optometry, Waterloo, ON N2L 3G1, Canada
关键词
corneal thickness; corneal epithelial thickness; overnight swelling; optical coherence tomography;
D O I
10.1097/00003226-200107000-00008
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To determine the feasibility of optical coherence tomography (OCT) measurement of overnight corneal swelling and deswelling and, specifically, to examine overnight changes in the corneal epithelium and recovery during the day. Methods. Ten healthy volunteers were recruited. Corneal OCT imaging was performed at 10:00 PM (baseline), 8:30 AM, and every 2 hours thereafter until 4:30 PM. Either the right or left eye was taped shut (using a gauze pad and surgical tape) until the 8:30 AM session of the next day. Measurements were made along a l-mm strip centered on the visual axis. Results. At baseline, there were no differences in corneal or epithelial thickness between control and experimental eyes (all p > 0.05). Immediately after patch removal, corneal and epithelial thicknesses of patched eyes were higher than the baseline (all p < 0.05). In patched eyes, the cornea and epi thelium swelled 5.5% and 8.1% overnight, respectively (p > 0.05). Two hours later, the epithelial thickness of the experimental eyes recovered to baseline level (p > 0.05), but corneal thickness did not reach to baseline level until 4 hours after patch removal. For control eyes, there were no differences compared with baseline (all p > 0.05). Conclusion. Both cornea and corneal epithelium experience proportionately similar amounts of overnight swelling. Recovery of overnight swelling may be slower for the cornea than for the epithelium. OCT provides valuable information about anterior segment morphometry.
引用
收藏
页码:480 / 483
页数:4
相关论文
共 50 条
  • [41] Diurnal Variation of Corneal Shape and Thickness
    Read, Scott A.
    Collins, Michael J.
    OPTOMETRY AND VISION SCIENCE, 2009, 86 (03) : 170 - 180
  • [42] Diurnal corneal thickness variation in Fuchs Endothelial Corneal Dystrophy
    Fritz, Marianne
    Grewing, Viviane
    Boehringer, Daniel
    Maier, Philip
    Lapp, Thabo
    Reinhard, Thomas
    Wacker, Katrin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [43] Comparison of corneal thickness measured with optical coherence tomography, ultrasonic pachymetry, and a scanning slit method
    Thomas, Joseph
    Wang, Jianhua
    Rollins, Andrew M.
    Sturm, Julie
    JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (07) : 671 - 678
  • [44] Repeatability and reproducibility of corneal thickness measurements by optical coherence tomography
    Muscat, S
    McKay, N
    Parks, S
    Kemp, E
    Keating, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 (06) : 1791 - 1795
  • [45] Corneal Epithelial Remodeling after LASIK Measured by Fourier-Domain Optical Coherence Tomography
    Tang, Maolong
    Li, Yan
    Huang, David
    JOURNAL OF OPHTHALMOLOGY, 2015, 2015
  • [46] Evaluation of Corneal Epithelial Thickness Imaged by High Definition Optical Coherence Tomography in Healthy Eyes
    Baghdasaryan, Elmira
    Tepelus, Tudor C.
    Marion, Kenneth M.
    Bagherinia, Homayoun
    Sadda, SriniVas R.
    Hsu, Hugo Y.
    CORNEA, 2019, 38 (01) : 62 - 66
  • [47] Author Response: Diurnal Variation of Retinal Thickness Measured by Optical Coherence Tomography in Normal Adults
    Jo, Young-Joon
    Heo, Dong-Won
    Shin, Yong-Il
    Kim, Jung-Yeul
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (03) : 1639 - 1640
  • [48] Corneal and epithelial thickness in keratoconus: A comparison of ultrasonic pachymetry Orbscan II, and optical coherence tomography
    Haque, S
    Simpson, T
    Jones, L
    JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (05) : 486 - 493
  • [49] Analysis of Compensatory Corneal Epithelial Thickness Changes in Keratoconus Using Corneal Tomography
    Franco, Jimena
    White, Craig A.
    Kruh, Jonathan N.
    CORNEA, 2020, 39 (03) : 298 - 302
  • [50] Investigation of corneal epithelial thickness and irregularity by optical coherence tomography after transepithelial photorefractive keratectomy
    Weng, Tzu-Heng
    Chang, Yu-Min
    Lin, Fu-Huang
    Weng, Zi-Xuan
    Wang, Tai-Wen
    Chen, Yi-Hao
    Tai, Ming-Cheng
    Chen, Jiann-Torng
    Liang, Chang-Min
    Lin, Ting-Yi
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2024, 107 (01) : 23 - 31