Diurnal variation of corneal and corneal epithelial thickness measured using optical coherence tomography

被引:150
|
作者
Feng, YW [1 ]
Varikooty, J [1 ]
Simpson, TL [1 ]
机构
[1] Univ Waterloo, Sch Optometry, Waterloo, ON N2L 3G1, Canada
关键词
corneal thickness; corneal epithelial thickness; overnight swelling; optical coherence tomography;
D O I
10.1097/00003226-200107000-00008
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To determine the feasibility of optical coherence tomography (OCT) measurement of overnight corneal swelling and deswelling and, specifically, to examine overnight changes in the corneal epithelium and recovery during the day. Methods. Ten healthy volunteers were recruited. Corneal OCT imaging was performed at 10:00 PM (baseline), 8:30 AM, and every 2 hours thereafter until 4:30 PM. Either the right or left eye was taped shut (using a gauze pad and surgical tape) until the 8:30 AM session of the next day. Measurements were made along a l-mm strip centered on the visual axis. Results. At baseline, there were no differences in corneal or epithelial thickness between control and experimental eyes (all p > 0.05). Immediately after patch removal, corneal and epithelial thicknesses of patched eyes were higher than the baseline (all p < 0.05). In patched eyes, the cornea and epi thelium swelled 5.5% and 8.1% overnight, respectively (p > 0.05). Two hours later, the epithelial thickness of the experimental eyes recovered to baseline level (p > 0.05), but corneal thickness did not reach to baseline level until 4 hours after patch removal. For control eyes, there were no differences compared with baseline (all p > 0.05). Conclusion. Both cornea and corneal epithelium experience proportionately similar amounts of overnight swelling. Recovery of overnight swelling may be slower for the cornea than for the epithelium. OCT provides valuable information about anterior segment morphometry.
引用
收藏
页码:480 / 483
页数:4
相关论文
共 50 条
  • [21] Corneal and corneal epithelial thickness distribution characteristics in healthy North Indian eyes using spectral domain optical coherence tomography
    Malhotra, Chintan
    Gupta, Barkha
    Dhiman, Rajneesh
    Jain, Arun K.
    Gupta, Amit
    Ram, Jagat
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (04) : 1171 - 1178
  • [22] Comparison of central corneal thickness measured by automatic and manual analysis of optical coherence tomography
    Carlo Bruttini
    Roberto Esposti
    Alfredo Pece
    Giulio Maione
    Paolo Cavallari
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2024, 262 : 1857 - 1863
  • [23] Impact of pterygium on central corneal thickness measured by optical coherence tomography in older adults
    Dotto, Pedro Gabriel
    Salomao, Solange Rios
    Fernandes, Arthur Gustavo
    Mitsuhiro, Marcia Regina Kimie Higashi
    Ferraz, Nivea Nunes
    Furtado, Joao Marcello
    Watanabe, Sung Song
    Cypel, Marcela
    Sacai, Paula Yuri
    Cunha, Cristina Coimbra
    Vasconcelos, Galton Carvalho
    Morales, Paulo Henrique
    Cohen, Marcos Jacob
    Cohen, Jacob Moyses
    Campos, Mauro
    Munoz, Sergio
    Belfort Jr, Rubens
    Berezovsky, Adriana
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (04) : 1583 - 1588
  • [24] Comparison of central corneal thickness measured by automatic and manual analysis of optical coherence tomography
    Bruttini, Carlo
    Esposti, Roberto
    Pece, Alfredo
    Maione, Giulio
    Cavallari, Paolo
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (06) : 1857 - 1863
  • [25] Wide Corneal Epithelial Thickness Mapping in Eyes With Topical Antiglaucoma Therapy Using Optical Coherence Tomography
    Ye, Yiming
    Xu, Yunzhi
    Yang, Yangfan
    Fan, Yanmei
    Liu, Pingping
    Yu, Keming
    Yu, Minbin
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2022, 11 (01):
  • [26] Normal and Keratoconic Corneal Epithelial Thickness Mapping using Fourier-Domain Optical Coherence Tomography
    Li, Yan
    Tan, Ou
    Huang, David
    MEDICAL IMAGING 2011: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2011, 7965
  • [27] Evaluation of corneal epithelial and stromal thickness in keratoconus using spectral-domain optical coherence tomography
    Maeda, Naoyuki
    Nakagawa, Tomoya
    Higashiura, Ritsuko
    Fuchihata, Mutsumi
    Koh, Shizuka
    Nishida, Kohji
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2014, 58 (05) : 389 - 395
  • [28] Evaluation of corneal epithelial thickness in glaucomatous patients using anterior-segment optical coherence tomography
    Montorio, Daniela
    Cennamo, Gilda
    Breve, Maria A.
    Fiore, Ugo
    Reibaldi, Michele
    Morra, Vincenzo Brescia
    Cennamo, Giovanni
    JOURNAL OF BIOPHOTONICS, 2020, 13 (01)
  • [29] Simultaneous Corneal Topography and Epithelial Thickness Mapping from a Single Measurement Using Optical Coherence Tomography
    Sikorski, Bartosz L.
    JOURNAL OF OPHTHALMOLOGY, 2022, 2022
  • [30] Evaluation of corneal epithelial and stromal thickness in keratoconus using spectral-domain optical coherence tomography
    Naoyuki Maeda
    Tomoya Nakagawa
    Ritsuko Higashiura
    Mutsumi Fuchihata
    Shizuka Koh
    Kohji Nishida
    Japanese Journal of Ophthalmology, 2014, 58 : 389 - 395