Comparative Analysis of Heat Pump System with IHX Using R1234yf and R134a

被引:4
|
作者
Santa, Robert [1 ]
机构
[1] Univ Dunaujvaros, Dept Mech Engn, Tancsics Mihaly U 1-a, H-2400 Dunaujvaros, Hungary
来源
关键词
heat pump; IHX; R1234yf; R134a; COP; DROP-IN REPLACEMENT; EXERGY ANALYSIS; PERFORMANCE; EXCHANGER; R513A; R450A; ALTERNATIVES; MIXTURE; R1234ZE(E); ENERGY;
D O I
10.3311/PPme.18390
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This research presents an energy performance analysis of the heat pump system with internal heat exchanger (IHX). The mathematical model of the heat pump outlined in this paper has been created by the author, it is steady-state with lumped parameters. The experimental validation of the model has been carried out using R1234yf and R134a as refrigerant. The aim of this work is to compare the energy performance in a wide range of operating conditions of a monitored heat pump system using both refrigerants. Finally, the heating capacity for R1234yf was lower from 0.63 % to 7.54 % compared with R134a, while the compressor power was similar from 0.12 % to 3.51 %. The COP values of R1234yf were lower than those obtained of R134a, ranging from 1.39 % to 4.22 %.
引用
收藏
页码:363 / 373
页数:11
相关论文
共 50 条
  • [31] Experimental study on the flammability ofanew type of refrigerant R1234yf/R134a
    Chen, Guangming (gmchen@zju.edu.cn), 1600, Science Press (37):
  • [32] Experimental Testing of a Water-to-Water Heat Pump with and without IHX by Using Refrigerants R1234yf and R1234ze(E)
    Bosnjakovic, Mladen
    Santa, Robert
    Katinic, Marko
    SUSTAINABILITY, 2023, 15 (11)
  • [33] HORIZONTAL CONVECTIVE BOILING OF R134A, R1234YF/R134A, AND R1234ZE(E) WITHIN A MICRO-FIN TUBE
    Kedzierski, M. A.
    Park, K. -J.
    JOURNAL OF ENHANCED HEAT TRANSFER, 2013, 20 (04) : 333 - 346
  • [34] Thermodynamic performance comparison and experimental study of mixed refrigerant R134a/R1234yf (R513A) and R134a
    Yang, Meng
    Zhang, Hua
    Qin, Yanbin
    Meng, Zhaofeng
    Huagong Jinzhan/Chemical Industry and Engineering Progress, 2019, 38 (03): : 1182 - 1189
  • [35] Performance of low GWP R1234yf/R134a mixture as a replacement for R134a in automotive air conditioning systems
    Meng, Zhaofeng
    Zhang, Hua
    Lei, Mingjing
    Qin, Yanbin
    Qiu, Jinyou
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 116 : 362 - 370
  • [36] Experimental comparison of an air-to-water refrigeration system working with R134a and R1234yf
    Illan-Gomez, F.
    Garcia-Cascales, J. R.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 97 : 124 - 131
  • [37] Energy, exergy and entropy analysis with R1234yf as an alternate refrigerant to R134a of automobile air conditioning system
    Patel, Bhaveshkumar
    Parekh, Ashok
    JOURNAL OF THERMAL ENGINEERING, 2024, 10 (01): : 101 - 114
  • [38] Performance Analysis of Refrigerants R1234yf, R1234ze and R134a in Ejector-Based Refrigeration Cycle
    Yadav, Ajay Kumar
    Neeraj
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2018, 26 (03)
  • [39] THEORETICAL STUDY OF HEAT PUMP SYSTEM USING R744/R1234YF AS REFRIGERANT
    Ju, Fujun
    Fan, Xiaowei
    Chen, Yaping
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2015, VOL 8B, 2016,
  • [40] A brief performance comparison of R1234yf and R134a in a bench tester for automobile applications
    Lee, Yohan
    Jung, Dongsoo
    APPLIED THERMAL ENGINEERING, 2012, 35 : 240 - 242