Sample-to-Answer Diagnostic System for the Detection of Circulating Histones in Whole Blood

被引:4
|
作者
Everitt, Micaela L. [1 ]
Boegner, David J. [1 ]
Birukov, Konstantin G. [2 ]
White, Ian M. [1 ]
机构
[1] Univ Maryland, Fischell Dept Bioengn, College Pk, MD 20740 USA
[2] Univ Maryland, Anesthesiol Dept, Med Ctr, Baltimore, MD 21201 USA
基金
美国国家科学基金会;
关键词
sample-to-answer; histones; whole blood; multiple organ failure; severe trauma; point-of-care; portable; LABEL-FREE DETECTION; LACTATE; MEDIATORS; POINT;
D O I
10.1021/acssensors.1c00886
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Severe internal trauma results in millions of hospitalizations each year, including thousands of deaths caused by subsequent multiple organ failure. The majority of these deaths occur within the first 24 h, and thus, rapid diagnosis of internal trauma severity is necessary for immediate treatment. For early organ damage identification, diagnosis in point-of-care settings is crucial for rapid triage and treatment. Recent reports suggest that circulating histones may serve as a biomarker for severe organ damage and the risk of multiple organ failure. Here, we report a point-of-care diagnostic system that utilizes the inherent interactions between histones and DNA for the fluorescence-based detection of histones in whole blood. In the assay, histones within the sample are wrapped by DNA, thus preventing an intercalating dye from binding the DNA and fluorescing. To allow for quantitative fluorescent measurements to be made in a point-of-care setting, we integrate a rapid, automated blood separation step into our assay. Furthermore, we eliminate manual reagent additions using a thermally responsive alkane partition (TRAP), thus making the system sample-to-answer. Finally, we demonstrate the assay in a portable fluorescence reader compatible with a point-of-care environment. We report a limit of detection 112 ng/mL in whole blood, suggesting that our device can be used to rapidly diagnose internal trauma severity and the likelihood of multiple organ failure in near-patient settings.
引用
收藏
页码:3006 / 3012
页数:7
相关论文
共 50 条
  • [41] Multiplex Detection of Gram-Positive Pathogens from Blood Culture Bottles with GenMark's Innovative Sample-to-Answer Platform
    Yousif, S.
    Heiling, T.
    Martinez, M.
    Liang, H.
    Maer, A.
    Chen, Y.
    Freeman-Cook, L.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2014, 16 (06): : 738 - 738
  • [42] Performance evaluation of a rapid molecular diagnostic, MultiCode based, sample-to-answer assay for the simultaneous detection of Influenza A, B and respiratory syncytial viruses
    Voermans, Jolanda J. C.
    Seven-Deniz, S.
    Fraaij, P. L. A.
    van der Eijk, Annemiek A.
    Koopmans, M. P. G.
    Pas, Suzan D.
    JOURNAL OF CLINICAL VIROLOGY, 2016, 85 : 65 - 70
  • [43] Sample-to-answer lateral flow assay with integrated plasma separation and NT-proBNP detection
    Strohmaier-Nguyen, Dan
    Horn, Carina
    Baeumner, Antje J.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (13) : 3107 - 3115
  • [44] Multiplex Detection of Gram-Negative Pathogens from Blood Culture Bottles with GenMark's Innovative Sample-to-Answer Platform
    Ivy, C. A.
    Sikhamsay, N. N.
    Haq, R.
    Brown, B. A.
    Freeman-Cook, L.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2014, 16 (06): : 739 - 739
  • [45] From sample-to-answer: Integrated genotyping and immunological analysis microfluidic platforms for the diagnostic and treatment of coeliac disease
    Jung, M.
    Hoeth, J.
    Erwes, J.
    Latta, D.
    Strobach, X.
    Hansen-Hagge, T.
    Klemm, R.
    Gaertner, C.
    Demiris, T. M.
    O'Sullivan, C.
    Ritzi-Lehnert, M.
    Drese, K. S.
    MICROFLUIDICS, BIOMEMS, AND MEDICAL MICROSYSTEMS IX, 2011, 7929
  • [46] CRISPR-based strategies for sample-to-answer monkeypox detection: current status and emerging opportunities
    Ahamed, Md Ahasan
    Politza, Anthony J.
    Liu, Tianyi
    Khalid, Muhammad Asad Ullah
    Zhang, Huanshu
    Guan, Weihua
    NANOTECHNOLOGY, 2025, 36 (04)
  • [47] A sample-to-answer DNA detection microfluidic system integrating sample pretreatment and smartphone-readable gradient plasmonic photothermal continuous-flow PCR
    Zhang, Zengming
    Zhao, Shuhao
    Jiang, Lei
    Wu, Junjun
    Zhao, Wenhan
    Guo, Xiaoniu
    Peng, Niancai
    Hu, Fei
    ANALYST, 2022, 147 (21) : 4876 - 4887
  • [48] A sample to answer molecular diagnostic system for fungal infection
    Xu, S.
    Lin, L.
    Lin, J.
    Zheng, L.
    Shen, Y.
    JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2019, 139 (05) : S85 - S85
  • [49] Sample-to-Answer Detection of SARS-CoV-2 Viremia Using Thermally Responsive Alkane Partitions
    Boegner, David J.
    Na, Miso
    Harris, Anthony D.
    Christenson, Robert H.
    Damcott, Colleen M.
    King, Brent
    Stubbs, Latoya
    Rock, Peter
    White, Ian M.
    ANALYTICAL CHEMISTRY, 2024, 96 (29) : 12049 - 12056
  • [50] An Integrated Paper Microfluidic Device Based on Isothermal Amplification for Simple Sample-to-Answer Detection of Campylobacter jejuni
    Chen, Yunxuan
    Hu, Yaxi
    Lu, Xiaonan
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2023, 89 (07)