An Integrated Paper Microfluidic Device Based on Isothermal Amplification for Simple Sample-to-Answer Detection of Campylobacter jejuni

被引:15
|
作者
Chen, Yunxuan [1 ]
Hu, Yaxi [1 ,2 ]
Lu, Xiaonan [1 ,3 ]
机构
[1] Univ British Columbia, Fac Land & Food Syst, Food Nutr & Hlth Program, Vancouver, BC, Canada
[2] Carleton Univ, Dept Chem, Food Sci Program, Ottawa, ON, Canada
[3] McGill Univ Macdonald Campus, Dept Food Sci & Agr Chem, Quebec City, PQ, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
microfluidic "lab-on-a-chip; point-of-need diagnostics; recombinase polymerase amplification; lateral flow assay; Campylobacter jejuni; poultry; PCR; DNA; QUANTIFICATION; PATHOGENESIS; INFECTIONS; ASSAY; COLI; FOOD;
D O I
10.1128/aem.00695-23
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Campylobacter jejuni is recognized as the most common species in the genus Campylobacter that causes foodborne diseases. The main reservoirs harboring C. jejuni are poultry products, which are associated with most illnesses, creating a demand for effective detection methods to achieve point-of-need diagnostics. We developed an easy-to-use, hybrid paper/polymer-based microfluidic device that integrates paper-based DNA extraction, isothermal nucleic acid amplification, and lateral flow detection. Overall, the recombinase polymerase amplification (RPA) reaction was completed in 20 min and demonstrated 100% specificity to C. jejuni, including 2 reference strains and 6 wild strains isolated from the agroecosystem, 9 other Campylobacter subspecies strains, and 11 non-Campylobacter strains. The limit of detection (LOD) was 46 CFU/mL with DNA extracted on the cellulose paper. The sensitivity was reduced to 460 CFU/mL on the integrated hybrid paper/polymer-based microfluidic device. This device could detect C. jejuni spiked at concentrations ranging from 10(1) to 10(2) CFU/g in chicken meat after an enrichment of 5 to 10 h. For C. jejuni levels of >10(2) CFU/g, it managed to confirm positive results immediately, without bacterial enrichment. RPA reagents and primers remained stable on the paper platform at 22 & DEG;C for 12 h. After lyophilization and storage on paper, the RPA reaction showed consistent sensitivity for 3 days, and the LOD was reduced to 10(3) CFU/mL when storage was extended to 25 days. The use of this hybrid paper/polymer-based microfluidic device enabled detection of Campylobacter in foods with high specificity and sensitivity, demonstrating its potential as a reliable point-of-need diagnostic platform for on-site conditions due to its low cost, portability, and simplicity.IMPORTANCE The global health and economic burden of Campylobacter prompts the development of novel detection techniques that can be implemented in resource-limited and on-site settings. This study described point-of-need identification of C. jejuni using a hybrid paper/polymer-based microfluidic device that is easy to operate. This device had high specificity and sensitivity toward C. jejuni and significantly reduced the total analysis time compared to conventional culture-based methods. Nucleic acid extraction was simplified from intensive pipetting to a paper dipstick, making it more convenient for use in the field as a promising tool for future routine surveillance and outbreak investigation. The global health and economic burden of Campylobacter prompts the development of novel detection techniques that can be implemented in resource-limited and on-site settings. This study described point-of-need identification of C. jejuni using a hybrid paper/polymer-based microfluidic device that is easy to operate.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Integrated microfluidic device of DNA extraction, recombinase polymerase amplification and micro-capillary electrophoresis for sample-to-answer detection of Salmonella Typhimurium
    Nguyen, Van Dan
    Sureshkumar, Gayathri
    Seo, Tae Seok
    SENSORS AND ACTUATORS B-CHEMICAL, 2025, 435
  • [2] Integrated Microcapillary for Sample-to-Answer Nucleic Acid Pretreatment, Amplification, and Detection
    Zhang, Lu
    Zhang, Yi
    Wang, Chunyan
    Feng, Qiang
    Fan, Fei
    Zhang, Guojun
    Kang, Xixiong
    Qin, Xuzhen
    Sun, Jiashu
    Li, Yinghui
    Jiang, Xingyu
    ANALYTICAL CHEMISTRY, 2014, 86 (20) : 10461 - 10466
  • [3] Centrifugal microfluidic system for colorimetric sample-to-answer detection of viral pathogens
    Geissler, Matthias
    Brassard, Daniel
    Adam, Nadine
    Nasheri, Neda
    Pilar, Ana Victoria C.
    Tapp, Kyle
    Clime, Liviu
    Miville-Godin, Caroline
    Mounier, Maxence
    Nassif, Christina
    Lukic, Ljuboje
    Malic, Lidija
    Corneau, Nathalie
    Veres, Teodor
    LAB ON A CHIP, 2024, 24 (04) : 668 - 679
  • [4] Multiplex sample-to-answer detection of bacteria using a pipette-actuated capillary array comb with integrated DNA extraction, isothermal amplification, and smartphone detection
    Hui, Junhou
    Gu, Yin
    Zhu, Yuanshou
    Chen, Yanjing
    Guo, Shu-juan
    Tao, Sheng-ce
    Zhang, Yan
    Liu, Peng
    LAB ON A CHIP, 2018, 18 (18) : 2854 - 2864
  • [5] Development and evaluation of a loop-mediated isothermal amplification assay for rapid and simple detection of Campylobacter jejuni and Campylobacter coli
    Yamazaki, Wataru
    Taguchi, Masumi
    Ishibashi, Masanori
    Kitazato, Miyoshi
    Nukina, Masafumi
    Misawa, Naoaki
    Inoue, Kiyoshi
    JOURNAL OF MEDICAL MICROBIOLOGY, 2008, 57 (04) : 444 - 451
  • [6] An integrated paper-based sample-to-answer biosensor for nucleic acid testing at the point of care
    Choi, Jane Ru
    Hu, Jie
    Tang, Ruihua
    Gong, Yan
    Feng, Shangsheng
    Ren, Hui
    Wen, Ting
    Li, XiuJun
    Abas, Wan Abu Bakar Wan
    Pingguan-Murphy, Belinda
    Xu, Feng
    LAB ON A CHIP, 2016, 16 (03) : 611 - 621
  • [7] DNAzyme-integrated plasmonic nanosensor for bacterial sample-to-answer detection
    Yu, Fang
    Li, Yun
    Li, Mingyu
    Tang, Longhua
    He, Jian-Jun
    BIOSENSORS & BIOELECTRONICS, 2017, 89 : 880 - 885
  • [8] Rapid Pomegranate Juice Authentication Using a Simple Sample-to-Answer Hybrid Paper/Polymer-Based Lab-on-a-Chip Device
    Hu, Yaxi
    Lu, Xiaonan
    ACS SENSORS, 2020, 5 (07) : 2168 - 2176
  • [9] A microfluidic chip with integrated plasma separation for sample-to-answer detection of multiple chronic disease biomarkers in whole blood
    Zhou, Yuan
    Cui, Aiping
    Xiang, Dongliu
    Wang, Qing
    Huang, Jin
    Liu, Jianbo
    Yang, Xiaohai
    Wang, Kemin
    TALANTA, 2024, 280
  • [10] An integrated sample-to-answer graphene microchip for ultrafast detection of multiple microorganisms
    Fu, Quanying
    Feng, Shaoqiong
    Xiao, Zihan
    Gong, Keye
    Pang, Xueyuan
    Yang, Yuxiao
    Zhou, Cuiping
    Liu, Haidong
    Wang, Jiasi
    Zhou, Jianhua
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 409