An Integrated Paper Microfluidic Device Based on Isothermal Amplification for Simple Sample-to-Answer Detection of Campylobacter jejuni

被引:15
|
作者
Chen, Yunxuan [1 ]
Hu, Yaxi [1 ,2 ]
Lu, Xiaonan [1 ,3 ]
机构
[1] Univ British Columbia, Fac Land & Food Syst, Food Nutr & Hlth Program, Vancouver, BC, Canada
[2] Carleton Univ, Dept Chem, Food Sci Program, Ottawa, ON, Canada
[3] McGill Univ Macdonald Campus, Dept Food Sci & Agr Chem, Quebec City, PQ, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
microfluidic "lab-on-a-chip; point-of-need diagnostics; recombinase polymerase amplification; lateral flow assay; Campylobacter jejuni; poultry; PCR; DNA; QUANTIFICATION; PATHOGENESIS; INFECTIONS; ASSAY; COLI; FOOD;
D O I
10.1128/aem.00695-23
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Campylobacter jejuni is recognized as the most common species in the genus Campylobacter that causes foodborne diseases. The main reservoirs harboring C. jejuni are poultry products, which are associated with most illnesses, creating a demand for effective detection methods to achieve point-of-need diagnostics. We developed an easy-to-use, hybrid paper/polymer-based microfluidic device that integrates paper-based DNA extraction, isothermal nucleic acid amplification, and lateral flow detection. Overall, the recombinase polymerase amplification (RPA) reaction was completed in 20 min and demonstrated 100% specificity to C. jejuni, including 2 reference strains and 6 wild strains isolated from the agroecosystem, 9 other Campylobacter subspecies strains, and 11 non-Campylobacter strains. The limit of detection (LOD) was 46 CFU/mL with DNA extracted on the cellulose paper. The sensitivity was reduced to 460 CFU/mL on the integrated hybrid paper/polymer-based microfluidic device. This device could detect C. jejuni spiked at concentrations ranging from 10(1) to 10(2) CFU/g in chicken meat after an enrichment of 5 to 10 h. For C. jejuni levels of >10(2) CFU/g, it managed to confirm positive results immediately, without bacterial enrichment. RPA reagents and primers remained stable on the paper platform at 22 & DEG;C for 12 h. After lyophilization and storage on paper, the RPA reaction showed consistent sensitivity for 3 days, and the LOD was reduced to 10(3) CFU/mL when storage was extended to 25 days. The use of this hybrid paper/polymer-based microfluidic device enabled detection of Campylobacter in foods with high specificity and sensitivity, demonstrating its potential as a reliable point-of-need diagnostic platform for on-site conditions due to its low cost, portability, and simplicity.IMPORTANCE The global health and economic burden of Campylobacter prompts the development of novel detection techniques that can be implemented in resource-limited and on-site settings. This study described point-of-need identification of C. jejuni using a hybrid paper/polymer-based microfluidic device that is easy to operate. This device had high specificity and sensitivity toward C. jejuni and significantly reduced the total analysis time compared to conventional culture-based methods. Nucleic acid extraction was simplified from intensive pipetting to a paper dipstick, making it more convenient for use in the field as a promising tool for future routine surveillance and outbreak investigation. The global health and economic burden of Campylobacter prompts the development of novel detection techniques that can be implemented in resource-limited and on-site settings. This study described point-of-need identification of C. jejuni using a hybrid paper/polymer-based microfluidic device that is easy to operate.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Origami-based "Book" shaped three-dimensional electrochemical paper microdevice for sample-to-answer detection of pathogens
    He, Tao
    Li, Jingwen
    Liu, Lisheng
    Ge, Shenguang
    Yan, Mei
    Liu, Haiyun
    Yu, Jinghua
    RSC ADVANCES, 2020, 10 (43) : 25808 - 25816
  • [22] Sample-to-answer lateral flow assay with integrated plasma separation and NT-proBNP detection
    Strohmaier-Nguyen, Dan
    Horn, Carina
    Baeumner, Antje J.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (13) : 3107 - 3115
  • [23] Paper-Based Bacterial Lysis Enables Sample-to-Answer Home-based DNA Testing
    Chondrogiannis, Georgios
    Reu, Pedro
    Hamedi, Mahiar M.
    ADVANCED MATERIALS TECHNOLOGIES, 2023, 8 (04)
  • [24] A LMOF/MIP paper-based chip and analysis of tetracycline in foodstuff with sample-to-answer performance
    Li, Han
    Wang, Donghui
    Liu, Wei
    Ma, Zhan
    Wang, Dingnan
    Li, Yang
    Huan, Weiwei
    Zhang, Yiming
    TALANTA, 2025, 281
  • [25] Establishment of Sample-to-Answer Loop-Mediated Isothermal Amplification-Based Nucleic Acid Testing Using the Sampling, Processing, Incubation, Detection and Lateral Flow Immunoassay Platforms
    Pommies, Lilas
    Boutal, Herve
    Fras, David
    Volland, Herve
    BIOSENSORS-BASEL, 2024, 14 (12):
  • [26] Paper-based sample-to-answer molecular diagnostic platform for point-of-care diagnostics
    Choi, Jane Ru
    Tang, Ruihua
    Wang, ShuQi
    Abas, Wan Abu Bakar Wan
    Pingguan-Murphy, Belinda
    Xu, Feng
    BIOSENSORS & BIOELECTRONICS, 2015, 74 : 427 - 439
  • [27] A rapid sample-to-answer analytical detection of genetically modified papaya using loop-mediated isothermal amplification assay on lab-on-a-disc for field use
    Loo, Jacky
    But, Grace Wing-Chiu
    Kwok, Ho-Chin
    Lau, Pui-Man
    Kong, Siu-Kai
    Ho, Ho-Pui
    Shaw, Pang-Chui
    FOOD CHEMISTRY, 2019, 274 : 822 - 830
  • [28] Embedded-deep-learning-based sample-to-answer device for on-site malaria diagnosis
    Bae, Chae Yun
    Shin, Young Min
    Kim, Mijin
    Song, Younghoon
    Lee, Hong Jong
    Kim, Kyung Hwan
    Lee, Hong Woo
    Kim, Yong Jun
    Kanyemba, Creto
    Lungu, Douglas K.
    Kang, Byeong-il
    Han, Seunghee
    Beck, Hans-Peter
    Cho, Shin-Hyeong
    Woo, Bo Mee
    Lim, Chan Yang
    Choi, Kyung-Hak
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [29] Miniaturized electrophoresis: An integrated microfluidic cartridge with functionalized hydrogel-assisted LAMP for sample-to-answer analysis of nucleic acid
    Kumar, Natish
    Kumari, Monika
    Chander, Devtulya
    Dogra, Sandeep
    Chaubey, Asha
    Arun, Ravi Kumar
    BIOMICROFLUIDICS, 2024, 18 (06)
  • [30] An integrated microfluidic loop-mediated-isothermal-amplification system for rapid sample pre-treatment and detection of viruses
    Wang, Chih-Hung
    Lien, Kang-Yi
    Wang, Ting-Yu
    Chen, Tzong-Yueh
    Lee, Gwo-Bin
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (05): : 2045 - 2052