An Integrated Paper Microfluidic Device Based on Isothermal Amplification for Simple Sample-to-Answer Detection of Campylobacter jejuni

被引:15
|
作者
Chen, Yunxuan [1 ]
Hu, Yaxi [1 ,2 ]
Lu, Xiaonan [1 ,3 ]
机构
[1] Univ British Columbia, Fac Land & Food Syst, Food Nutr & Hlth Program, Vancouver, BC, Canada
[2] Carleton Univ, Dept Chem, Food Sci Program, Ottawa, ON, Canada
[3] McGill Univ Macdonald Campus, Dept Food Sci & Agr Chem, Quebec City, PQ, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
microfluidic "lab-on-a-chip; point-of-need diagnostics; recombinase polymerase amplification; lateral flow assay; Campylobacter jejuni; poultry; PCR; DNA; QUANTIFICATION; PATHOGENESIS; INFECTIONS; ASSAY; COLI; FOOD;
D O I
10.1128/aem.00695-23
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Campylobacter jejuni is recognized as the most common species in the genus Campylobacter that causes foodborne diseases. The main reservoirs harboring C. jejuni are poultry products, which are associated with most illnesses, creating a demand for effective detection methods to achieve point-of-need diagnostics. We developed an easy-to-use, hybrid paper/polymer-based microfluidic device that integrates paper-based DNA extraction, isothermal nucleic acid amplification, and lateral flow detection. Overall, the recombinase polymerase amplification (RPA) reaction was completed in 20 min and demonstrated 100% specificity to C. jejuni, including 2 reference strains and 6 wild strains isolated from the agroecosystem, 9 other Campylobacter subspecies strains, and 11 non-Campylobacter strains. The limit of detection (LOD) was 46 CFU/mL with DNA extracted on the cellulose paper. The sensitivity was reduced to 460 CFU/mL on the integrated hybrid paper/polymer-based microfluidic device. This device could detect C. jejuni spiked at concentrations ranging from 10(1) to 10(2) CFU/g in chicken meat after an enrichment of 5 to 10 h. For C. jejuni levels of >10(2) CFU/g, it managed to confirm positive results immediately, without bacterial enrichment. RPA reagents and primers remained stable on the paper platform at 22 & DEG;C for 12 h. After lyophilization and storage on paper, the RPA reaction showed consistent sensitivity for 3 days, and the LOD was reduced to 10(3) CFU/mL when storage was extended to 25 days. The use of this hybrid paper/polymer-based microfluidic device enabled detection of Campylobacter in foods with high specificity and sensitivity, demonstrating its potential as a reliable point-of-need diagnostic platform for on-site conditions due to its low cost, portability, and simplicity.IMPORTANCE The global health and economic burden of Campylobacter prompts the development of novel detection techniques that can be implemented in resource-limited and on-site settings. This study described point-of-need identification of C. jejuni using a hybrid paper/polymer-based microfluidic device that is easy to operate. This device had high specificity and sensitivity toward C. jejuni and significantly reduced the total analysis time compared to conventional culture-based methods. Nucleic acid extraction was simplified from intensive pipetting to a paper dipstick, making it more convenient for use in the field as a promising tool for future routine surveillance and outbreak investigation. The global health and economic burden of Campylobacter prompts the development of novel detection techniques that can be implemented in resource-limited and on-site settings. This study described point-of-need identification of C. jejuni using a hybrid paper/polymer-based microfluidic device that is easy to operate.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] A real-time isothermal amplification based portable microfluidic system for simple and reliable detection ofVibrio splendidus
    Zhong, Runtao
    Liu, Shilin
    Wang, Xiaohui
    Zhang, Guohao
    Gong, Ning
    Wang, Mengyu
    Sun, Yeqing
    ANALYTICAL METHODS, 2020, 12 (23) : 2985 - 2994
  • [42] Polymerase Chain Reaction-Free, Sample-to-Answer Bacterial Detection in 30 Minutes with Integrated Cell Lysis
    Lam, Brian
    Fang, Zhichao
    Sargent, Edward H.
    Kelley, Shana O.
    ANALYTICAL CHEMISTRY, 2012, 84 (01) : 21 - 25
  • [43] Fluidic handling system for PCR-based sample-to-answer detection of viral nucleic acids
    Seder, Islam
    Kim, Dong-Min
    Hwang, Sang-Hyun
    Sung, Heungsup
    Kim, Dong-Eun
    Kim, Sung-Jin
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 349
  • [44] A fully disposable and integrated paper-based device for nucleic acid extraction, amplification and detection
    Tang, Ruihua
    Yang, Hui
    Gong, Yan
    You, MinLi
    Liu, Zhi
    Choi, Jane Ru
    Wen, Ting
    Qu, Zhiguo
    Mei, Qibing
    Xu, Feng
    LAB ON A CHIP, 2017, 17 (07) : 1270 - 1279
  • [45] A paper and plastic device for the combined isothermal amplification and lateral flow detection of Plasmodium DNA
    Michael S. Cordray
    Rebecca R. Richards-Kortum
    Malaria Journal, 14
  • [46] Loop-Mediated Isothermal Amplification (LAMP) for Detection of Campylobacter jejuni and C. coli in Thai Children with Diarrhea
    Ngan Thi Kim Pham
    Quang Duy Trinh
    Khamrin, Pattara
    Ukarapol, Nuthapong
    Kongsricharoern, Tipachan
    Yamazaki, Wataru
    Komine-Aizawa, Shihoko
    Okitsu, Shoko
    Maneekarn, Niwat
    Hayakawa, Satoshi
    Ushijima, Hiroshi
    JAPANESE JOURNAL OF INFECTIOUS DISEASES, 2015, 68 (05) : 432 - 433
  • [47] Development of a Loop-Mediated Isothermal Amplification Assay for Rapid, Sensitive Detection of Campylobacter jejuni in Cattle Farm Samples
    Dong, Hee-Jin
    Cho, Ae-Ri
    Hahn, Tae-Wook
    Cho, Seongbeom
    JOURNAL OF FOOD PROTECTION, 2014, 77 (09) : 1593 - 1598
  • [48] A paper and plastic device for the combined isothermal amplification and lateral flow detection of Plasmodium DNA
    Cordray, Michael S.
    Richards-Kortum, Rebecca R.
    MALARIA JOURNAL, 2015, 14
  • [49] Sample-to-Answer Hepatitis B Virus DNA Detection from Whole Blood on a Centrifugal Microfluidic Platform with Double Rotation Axes
    Li, Lei
    Miao, Baogang
    Li, Zheng
    Sun, Zhengming
    Peng, Niancai
    ACS SENSORS, 2019, 4 (10) : 2738 - 2745
  • [50] Chlorophyll-based wicking sensing bioplatform coupled with a smartphone-based sample-to-answer analytical device for on-site detection of picric acid
    Shafizadeh M.
    Abbasi-Moayed S.
    Hamzei Z.
    Keshavarz A.
    Yousefi S.
    Hormozi-Nezhad M.R.
    Golmohammadi H.
    Biosensors and Bioelectronics: X, 2022, 11